• Title/Summary/Keyword: fatigue endurance

Search Result 210, Processing Time 0.03 seconds

Fatigue Analysis for Electro-Mechanical Brake Caliper based on Eccentric Rotating Shaft (편심회전축 기반의 전기기계식 제동장치의 피로수명 해석)

  • Oh, Hyuck Keun;Beak, Seung-Koo;Jeon, Chang-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.596-603
    • /
    • 2020
  • 'Electro-Mechanical Brake (EMB) is a novel braking system for automobiles and railway vehicles, and research in this area is actively underway. The current braking system for railway vehicles generates a braking force using a pneumatic cylinder, but the EMB system generates the force through a combination of an electric motor and gears. In this study, the design of an EMB system that meets the domestic standards was conducted through the finite element modeling and fatigue analysis of an eccentric rotating shaft-based EMB system capable of generating a high clamping force. At this time, to improve the accuracy of fatigue analysis, three types of fatigue test specimens, which were subjected to the same heat treatment as the materials used in the prototype, were produced, and the fatigue tests were performed for each material. The fatigue properties (S-N curves) were obtained from the fatigue test results for each material and reflected in the analysis model. The results of fatigue analysis confirmed that the design of the EMB prototype could satisfy the maximum commercial braking/relaxation of 530,000 times, which was the endurance life condition for domestic railway vehicles. In addition, based on this design, a prototype will be manufactured, and endurance testing will be completed to demonstrate the durability characteristics of the developed prototype.

Fatigue Behavior with Respect to Rolling and Residual Stress in Butt-welded Steel Plate (맞대기 용접 강판재에서 압연 및 잔류응력에 의한 피로거동)

  • Lee Yong-Bok;Oh Byung-Duck;Kim Sung-Yeup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.7 s.250
    • /
    • pp.826-832
    • /
    • 2006
  • For the improvement of safety and endurance in welded steel structure, it is needed to consider welding residual stress distribution and rolling directional characteristics of materials. In this study, it was investigated experimentally about characteristics of fatigue crack propagation according to welding residual stress and rolling in FCAW(flux cored arc welding) butt-jointed steel plates. SS400 steel plates of 3mm thickness were selected and tested for this study. When the angles between tensile loading direction and rolling direction in welded materials are increased from $0^{\circ}\;to\;90^{\circ}$, their fatigue crack propagation rates are increased. These results are same as predicted increments of fatigue crack propagation rate when stress ratio is increased from 0 to 0.5. When the angles of rolling direction and welding direction to tensile loading direction are $0^{\circ}\;and\;90^{\circ}$ respectively, fatigue crack propagation rate in welded material is lowest.

An Experimental Study on the Strength Evaluation of A1-5052 Tensile-Shear Specimens Using a Mechanical Press Joining Method (기계적 프레스 접합법을 이용한 A1-5052 인장-전단 시험편의 강도 평가에 관한 실험적 연구)

  • 임두환;이병우;류현호;김호경
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.1
    • /
    • pp.58-64
    • /
    • 2003
  • A mechanical press joining was investigated in ender for joining A1-5052 sheets for automobile body weight reduction. Static tensile and fatigue tests were conducted using tensile-shear specimens for evaluation of fatigue strength of the joint. During Tox joining process for A1-5052 plates, using the current sheet thickness and punch diameter, the optimal applied punching force was found to be 32 kN under the current joining condition. For the static tensile-shear experiment results, the fracture mode is classified into interface fracture mode, in which the neck area fractured due to influence of neck thickness, and pull-out fracture mode due to influence of plastic deformation of the joining area. And, during fatigue tests for the A1-5052 tensile shear specimens, interface failure mode occurred in the region of low cycle. The fatigue endurance limit approached to 6 percents of the maximum applied load, considering fatigue lifetime of $2.5\times10^6$ cycles.

The Effects of the Microstructural Change of Dual Phase Steel on Fatigue Fracture Propagation (복합조직강의 미시조직변화가 피로파괴전파에 미치는 영향)

  • Oh, Sae-Wook;Kim, Ung-Jip
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.198-198
    • /
    • 1991
  • Not only difference of fatigue crack growth and propagation behavior resulted from the grain size, the hardness ratio and volume fraction in M.E.F. dual phase steel composed of martensite in hard phase and ferrite in soft phase, but also the effects of the plastic constraint were investigated by fracture mechanics and microstructural method. The main results obtained are as follows: 1) The fatigue endurance of M.E.F. steel increases with decreasing the grain size, increasing the ratio of hardness and volume fraction. 2) The initiation of slip and crack occures faster as the stress level goes higher. These phenomena result from the plastic constraint effect of the second phase. 3) The crack propagation rate in the constant stress level is faster as the grain size gets larger, the ratio of hardness lower and volume fraction smaller.

Fatigue Strength Evaluation of SPCC Cross-Tension Spot Weld Joints (냉간 압연강판 십자형 점용접부의 피로강도 평가)

  • Kim, Ho-Kyung;Choi, Deok-Ho;Yang, Kyoung-Tak
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.17-21
    • /
    • 2006
  • In this study, SPCC cross-tension type specimens produced under various spot welding conditions were tensile and fatigue tested. Decrease of 2 kA in normal current condition of 10 kA caused a large amount of reduction in both static joining strength and fatigue life. And 2 kA increase resulted in increase of static joining strength and an increase in low cycle regime but a decrease in high cycle regime, revealing the fact that fatigue strength rather than static joining strength would be a major factor during design process in view of the body endurance. As a results of estimating the fatigue lifetimes of various types of spot weld specimens. equivalent stress intensity factor is the proper parameter for predicting the lifetimes of various types of specimens. which can be expressed as ${\Delta}K_{eq}(N/nm^{1.5})=11550N^{-0.36}_{f}$.

Fatigue Fracture of NBR-coated SUS301 Thin Plate for MLS Gasket (MLS 가스겔용 NBR 피복 SUS301 박판의 피로파손)

  • Han, Byoung-Kee;Cho, Sung-San;Chang, Hoon;Kim, Beom-Keun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.207-212
    • /
    • 2004
  • Full-beads of multi-layer steel engine head gaskets that are used to seal the combustion gas between the head and the block are subject to cyclic bending stresses due to the variation of the head/block gap during engine operation. The S-N curve for the fatigue durability assessment of the full-bead formed on NBR-coated SUS301 thin plate is deduced from the axial fatigue test results because of the difficulty in conducting the bending fatigue test of thin plate. The experimental verification of the deduced S-N curve is presented. It is shown that the NBR coating increases the endurance limit of the plate significantly. Mechanism of crack nucleation and propagation in the full-bead is discussed with photographs of the fatigue cracks.

A Study on the Safety Estimation of Low Pressure Torsion mounted Turbine Blade (비틀림 마운트형 저압 터빈 블레이드의 안전성 평가에 관한 연구)

  • 홍순혁;조석수;주원식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.149-156
    • /
    • 2003
  • The estimation of fatigue limit for the component with complicated shape is difficult than of standard fatigue specimen, due to complex test equipment. So, we substitute maximum principle stress from FEM results for fatigue limit diagram made by standard fatigue specimen. Then we can estimate endurance safety of component with high trust. The static stress analysis, the nonlinear contact stress analysis and the model analysis for turbine blade is performed by ANSYS ver. 5.6. the comparison of maximum static stress around hole with maximum contact stress between pun and hole can make the cause of fracture for turbine blade clear. The difference of fatigue limit between fatigue test by standard specimen and in-service mechanical components is due to surface roughness and machining condition etc. In in-service mechanical components, Goodman diagram has to consider surface roughness for failure analysis. To find fracture mechanism of torison-mounted blade in nuclear plant. This study performs the static stress, the nonlinear contact stress and the modal analysis on torison-mounted blade with finite element method and makes the estimation for safety of turbine blade.

Improving Effects of Multigrain Feed on Endurance (혼합곡 식이의 지구력 향상 효과)

  • Oh, Hong-Geun;Park, Jung-Woo;Kang, Young-Rye;Kim, Jung-Hoon;Seo, Min-Young;Kim, Min-Gul;Doo, Jae-Kyun;Shin, Dong-Hwa;Jung, Eun-Soo;Chae, Soo-Wan;Kim, Ok-Jin;Lee, Hak-Yong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.12
    • /
    • pp.1700-1707
    • /
    • 2011
  • This study evaluated the effect of multigrain supplementation on exercise-related changes in running time and glycogen storage capacity of male SD rats engaged in treadmill exercise. Thirty-six 6-week-old rats were divided into six groups: normal (Nor) fed normal feed, control (Con) fed with 20% normal feed and 80% milled rice, test group one (GI) fed with multigrain feed I, test group two (GII) fed with multigrain feed II, test group three (GIII) fed with multigrain feed III, and test group four (GIV) fed with multigrain feed IV. Endurance tests by treadmill machine were administered after 24 days of multigrain feed supplementation and adaptive training. Running time was extended and glycogen storage capacity increased in the multigrain-treated group compared to the non-treated group. Also, the fatigue indicators of inorganic phosphorous, CPK, and lactate concentration were all reduced in the multigrain feed group compared to the control group after 25 min and/or exhausted exercise. But there was no difference in GOP, GTP, lactate, or LDH concentrations between the groups. Our results demonstrated that endurance improved with multigrain feed in rats. Specifically, running time, glycogen storage capacity, inorganic phosphorous, CPK, and lactate serum concentration increased. Importantly, the improvements in endurance brought about in the GII group fed with waxy barley was the greatest among the experimental groups.

A study on Mechanical and Fatigue Properties of Spheroidal Graphite Cast Iron (구상흑연주철의 기계적 성질및 피로특성에 관한 연구)

  • Park, No-Gwang;Kim, Chang-Ju;Jun, Eui-Jin
    • 한국기계연구소 소보
    • /
    • s.9
    • /
    • pp.83-93
    • /
    • 1982
  • The influence of different heat treatment conditions on microstructure, mechanical and fatigue properties of Spheroidal Graphite cast Iron with 0.4-0.6% Mn was investigated. 1) Maximum tensile strength was arrived by tempering at about $450^{\circ}C$after quenching. Tempering at higher than $600^{\circ}C$ was changed martensitic structure to ferritic structure and secondary graphites were precipitated. 2) The relationship between matrix hardness and total hardness of the specimens are as following. [HB]$T$=0.7[HB] [HB]$M$+35 Maximum tensile strength was arrived at the total hardness of HB400-450. 3) Endurance ratio decreases with increasing total hardness, and fatigue limits can be presumed from as following. $\sigmaf$=$\sigmat$

  • PDF

정적자세 유지시 수공구의 무게가 상완의 postural tremor에 미치는 영향에 관한 연구

  • 송호영;김재영;조창규;윤명환;이면우
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.151-157
    • /
    • 1996
  • Postural tremor of the upper arm in a static posture was measured to provide guidelines of hand tool weight. Three types of camera recording postures were selected. Postural tremor was measured on five levels of tool weights; no weight, 400g, 800, 1200g, and 1600g. For each conditions, upper arm postural tremor was measured together with EMG of biceps, deltoid, and pectoralis major, and Borg's CR-20 scale ratings of perceived exertion. Results of the experiment are as follows; Frequency analysis of tremor revealed that increased amplitude of frequency band of 2-4Hz and 10-14Hz was observed. Postural tremor of the upper arm maintained the initial level until fatigue developed. After the development of fatigue, the rate of the change of postural tremor was significantly increased. Different tool weights and hand postures showed different rate of tremor increase. And time to fatigue and the corresponding endurance time was positively correlated with Borg's RPF scores.

  • PDF