• Title/Summary/Keyword: fatigue design

Search Result 1,888, Processing Time 0.029 seconds

Torsional Behavior of Hybrid Truss Bridge according to Connection Systems (복합트러스교의 격점구조별 비틀림 거동)

  • Jung, Kwang-Hoe;Lee, Sang-Hyu;Yi, Jong-Won;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.63-72
    • /
    • 2013
  • HTB (hybrid truss bridge) steel truss webs instead of concrete webs in prestressed box girder bridges has been widely used in, because of its structural benefit such as relatively less self-weight and good aesthetics due to open web structure. Since the core technology of this bridge is the connection system between concrete slabs and steel truss members, several connection systems were proposed and experimentally evaluated. Also, the selected joint system was applied to the real bride design and construction. The researches were performed on the connection system, since it can affect the global behavior of this bridge such as flexural and fatigue behaviors as well as the local behavior around the connection region. The evaluation study showned that HTB applied to a curved bridge or a eccentric loading bridge, characteristic has a weak torsional capacity compared to an ordinary PSC box girder bridges due to the open structure of HTB. In this study, three box shaped hybrid truss specimens were made and the torsional test and evaluation for them were performed in order to find out the torsional behavior of HTB according to the connection system.

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

Low Temperature Structural Tests of a Composite Wing with Room Temperature-Curing Adhesive Bond (상온접합 본딩이 있는 복합재 날개의 저온 구조시험)

  • Ha, Jae Seok;Park, Chan Yik;Lee, Kee Bhum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.928-935
    • /
    • 2015
  • This paper presents low temperature structural tests of a UAV wing which has room temperature-curing adhesive bond. The wing structure is made of carbon fiber reinforced composites, and the skins are bonded to the inner structures (such as ribs and spars) using room temperature-curing adhesive bond. Also, to verify damage tolerance design of the wing structure, barely visible impact damages are intentionally created in the critical areas. The attachment fittings of the wing are fixed in a specially designed chamber which can simulate the low temperature environments of the operating altitudes. The test load is applied by hydraulic actuators which are placed outside the chamber. The structural tests consist of strain survey tests and a durability test for 1-life fatigue load spectrum. During the tests, strains of major parts are measured by strain gauges and FBG sensors. The change of the initial impact damages is also monitored using piezoelectric sensors. The 1-life damage tolerance of the composite structure is verified by the structural tests under the simulated environments.

A Study on Static and Fatigue Behavior of Restrained Concrete Decks without Rebar by Steel Strap (Steel Strap으로 횡구속된 무철근 바닥판의 정적 및 피로거동 특성 연구)

  • Jo, Byung Wan;Kim, Cheol Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.137-147
    • /
    • 2012
  • In the steel-free bridge concrete deck, steel straps are generally used instead of conventional steel rebar while laterally restrained in the perpendicular direction to the traffic in order fir the arching effect of concrete deck. In this paper, the minimum amount of FRP bar is to be suggested based on the structural strength, crack propagation, stress level and others in order to control cracks. As a result of laboratory tests, the structural strength of deck with 0.15 percentage of steel strap showed improved structural strength including ductility. The long-term serviceability of steel strap deck with FRP bar proved to satisfy the requirements and to be structurally stable while showing the amount of crack and residual vertical displacement within the allowable limits after two million cyclic loadings. The structural failure of RC bridge deck is generally caused from the punching shear rather than moment. Therefore, the ultimate load at failure could be estimated using the shear strength formula in the two-way slab based on ACI and AASHTO criteria. However the design criteria tend to underestimate the shear strength since they don't consider the arching effects and nonlinear fracture in bridge deck with lateral confinement. In this paper, an equation to estimate the punching shear strength of steel strap deck is to be developed considering the actual failure geometries and effect of lateral confinement by strap while the results are verified in accordance with laboratory tests.

Combined utilization with herbal products and prescribed drugs: A result from health examinee-based national survey (일부 종합병원의 건강검진 수검자들의 한약·양약 복합투여)

  • Park, Jong-Ku;Choi, Seo-Young;Koh, Kwang-Wook;Yu, Jun-Sang;Kim, Tae-Hun;Sohn, Dong-Kook;Hong, Ju-Hee;Song, Sung-Eun;Kim, Chun-Bae
    • Health Policy and Management
    • /
    • v.16 no.1
    • /
    • pp.1-16
    • /
    • 2006
  • Recently, there has been prevailing of the combined utilization (CU) with herbs and prescribed drugs in medical therapies in the world. But the information about frequency, efficacy and safety of this CU has not well known in Korea, yet. This study aimed to identify the status of CU by Koreans, and to inquire which side effects of CU represent to those people. A self-completed questionnaire survey was performed through each health examination center in twenty general hospitals and one oriental hospital. Of the initial 2,100 health examinees, 1,851 were participated in this survey, resulting in a response rate of 88.1%. The proportion of CD was 26.3%. The most commonly mentioned reason of CD was 'to promote general health and well-being' (17l persons, 35.5%). The main route of taking CD was self-purchase at drugstore or at herbs market, followed by the prescription of (oriental)physicians. 33.0% (151 persons) of those who took the CD rated it as effective. 93 respondents (19.8%) were experienced several adverse effects including nausea, fatigue, and dizziness. The growing simultaneous use of herbal products and pharmaceutical drugs by Korean consumers may be continuously increased the risk of herb-drug interactions. The medical professionals should be provided with comprehensive and up-to-date information about potential benefits and risks of herbs and prescribed drugs. In the future studies it may be recommended to deal common cold, health promotion, indigestion, headache, and hypertension for the effect and safety of the CD by well-organized prospective study design.

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

Joint Design and Strength Evaluation of Composite Air Spoiler for Ship (선박용 복합재 에어 스포일러의 체결부 설계 및 강도 평가)

  • Pi, June-Woo;Jeon, Sang-Bae;Lee, Guen-Ho;Jo, Young-Dae;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • Air spoiler, which can reduce the drag during operation, can be considered as a possible means to reduce carbon dioxide emission and to increase fuel efficiency. In this study, a composite air spoiler was designed and tested by static and repeated loads. The Green Water Pressure of 0.1 MPa a ship experiences during operation was perpendicularly applied to the air spoiler. Air spoiler was manufactured with sandwich panel which has glass fabric face and balsa core. Multiple sandwich panels were assembled to steel frame by bolt joint. The joint was designed to have bearing failure and examined by static and fatigue tests. Tests showed that the designed joint has enough margin of safety to endure joint failure. The developed sandwich panel to air spoiler is planned to be applied to a large scale commercial ship.

Development of the Inductive Proximity Sensor Module for Detection of Non-contact Vibration (비접촉 진동 검출을 위한 유도성 근접센서모듈 개발)

  • Nam, Si-Byung;Yun, Gun-Jin;Lim, Su-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.61-71
    • /
    • 2011
  • To measure the fatigue of metallic objects at high speed vibration while non-contact precision displacement measurement on how to have a lot of research conducted. Noncontact high-speed vibration detection sensor of the eddy current sensors and laser sensors are used, but it is very expensive. Recently, High-speed vibrations detection using an inexpensive inductive sensor to have been studied, but is still a beginner. In this paper, a new design of an inexpensive inductive proximity sensor has been suggested in order to measure high frequency dynamic displacements of metallic specimens in a noncontact manner. Detection of the existing inductive sensors, detection, integral, and amplified through a process to detect the displacement noise due to weak nature of analog circuits and integral factor in the process of displacement detection is slow. The proposed method could be less affected by noise, the analog receive and high-speed signal processing is a new way, because AD converter (Analog to Digital converter) without using the vibration frequency signals directly into digital signals are converted. In order to evaluate the sensing performance, The proposed sensor module using non-contact vibration signals were detected while shaker vibration frequencies from 30Hz to 1,100 Hz at intervals of vibrating metallic specimens. Experimental results, Vibration frequency detection range of the metallic specimins within close proximity to contactless 5mm could be measured from DC to 1,100Hz and vibration amplitude of the resolution was $20{\mu}m$. Therefore, the proposed non-contact inductive sensor module for precision vibration detection sensor is estimated to have sufficient performance.

Biomechanical considerations for the screw of implant prosthesis: A literature review (임플란트 나사에 적용되는 생역학적 원리: 문헌고찰)

  • Im, So-Min;Kim, Dae-Gon;Park, Chan-Jin;Cha, Min-Sang;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • Purpose: This article attempted to determine the factors affecting the preload and screw loosening. Methods: Available clinical studies from 1981 to 2008 from the PUBMED that presented screw loosening data and review articles regarding screw joint stability were evaluated. Eleven studies dealing the biomechanical principles of the screw mechanics were reviewed. Moreover, the results of our data were included. Results: The frequency of screw loosening was consequently reduced due to the advancement in torque tightening with torque wrench, screw material, coating technique for reducing the frictional force, and thread design, etc. If preload in the screw falls below a critical level, joint stability may be compromised, and the screw joint may fail clinically. The types of fatigue failure of screw were divided to adhesive wear, plastic deformation, and screw fracture. Conclusion: An optimum preload is essential to the success of the implant-abutment complex. To maintain optimum preload, using a torque wrench and re-tightening at recall time were needed.

The Effects of Cranio-Sacral Therapy on Brain Function Quotient of Elderly with Long-term Care Insurance Service (두개천골요법이 장기요양시설노인의 뇌기능지수에 미치는 효과)

  • Lee, Jung-eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.474-484
    • /
    • 2016
  • This study was performed to identify the effects of the improvement of brain function by CST on the elderly with the 2nd or 3rd grade of long-term care insurance service. A quasi-experimental design using a nonequivalent control group, pre-post test was used. A total of 12 elders (6 in the experimental group and 6 in the control group) were recruited. Upledger CST(10-Step Protocol) was performed on each subject for 50 minutes per session, once a week, for a total of 8 treatments over an 8 week period from Jan to Feb 2015. The brain function quotient was measured before the 1st CST and after the last CST by portable EEG measurement device using a 2 Channel neuro-feedback system. The data was analyzed by SPSS (Ver. 18.0) program. After CST intervention, the attention quotient (AQ), level of tension, anti-stress quotient (ASQ), emotion quotient (EQ) and brain quotient (BQ) of the experimental group was significantly better than that of the control group. These results showed that the CST was effective in reducing the level of fatigue by the AQ, increasing the physical and psychological stress relief by the ASQ, emotional balance by the EQ, and improving the total brain function by the BQ. Therefore, CST can be used as an effective intervention for improving the health and brain function of the elderly in health facilities.