• Title/Summary/Keyword: fatigue capacity

Search Result 244, Processing Time 0.027 seconds

A Study on Fatigue Test Procedure of a Composite Train Carbody (복합재 철도차량 차체의 피로내구시험 철차에 대한 연구)

  • Kim, Jung-Seok;Han, Seong-Ho;Seo, Seung-Il;Jeong, Jong-Cheol;Cho, Sea-Hyun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.234-238
    • /
    • 2005
  • This paper explains the fatigue test procedure of a composite train carbody. The composite carbody with length of 23m was manufactured as a sandwich structure composed of a 40mm-thick aluminium honeycomb core and 5mm-thick woven fabric carbon/epoxy face. In order to evaluate fatigue strength of the composite carbody, the carbody will be excited by two 50-ton capacity hydraulic actuators. The excitation frequency will be measured by natural frequency evaluation test under full weight condition. The test The fatigue test is to be conducted For $2{\times}10^6$cycles. During the fatigue test, the nondestructive tests using X-ray and liquid penetrant will be performed. From crack detection tests, the location and Fatigue crack progress will be investigated.

  • PDF

Effects of 2-Phase Matrix Structure on Fatigue Limit of High Strength Ductile Iron (고강도 구상흑연주철의 피로한도에 미치는 2상 기지조직의 영향)

  • Kim, Jin-Hak;Ji, Jueng-Keun;Kim, Min-Gun
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.75-79
    • /
    • 1999
  • Rotary bending fatigue tests were performed to investigate the effects of 2-phase matrix structure on fatigue limit with prepared specimens in high strength ductile irons. Two types of the specimens with different microstructures have been used. Series A has sorbite and series B has bainite. Fatigue limits of both specimens are improved comparing with as cast specimen. The fatigue limit is higher in series B than in series A. The reason why the fatigue limit of series A shows inferiority to that of series B is due to the transition of micro fatigue cracks to mesocrack occurs very rapidly, so increased stress intensity factor drives the fatigue crack growth. The higher fatigue limit of series B which has bainite is caused by the ${\gamma}$ layer contained in microstructure impede the rapid growth of micro fatigue crack to mesocrack and ${\alpha}$ layer around graphite has the higher capacity for the absorption of plastic deformation energy than sorbite.

  • PDF

Fatigue Characteristics of Load Carring Cruciform Fillet Welded Joints According to Welding Methods (용접방법에 따른 하중전달 십자형 필렛 용접부의 피로특성)

  • 이용복;오병덕
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.125-133
    • /
    • 2002
  • In this study, it was investigated about endurance limit and fatigue behavior of load carrying fillet welded cruciform joints according to welding methods of SMAW, SAW, MIG and FCAW commonly using for welding structures in present. Endurance limit carried omit highly in the order of SMAW, MIG, SAW, FCAW and fatigue crack propagation ratio carried out lowly in the order of SMAW, MIG, FCAW, SAW. By these results, it is needed to use SMAW or MIG welding methods for welding structures with small welding capacity and SAW or FCAW methods for large welding structures after due consideration about economic gains and operation efficiency of welding. Fatigue crack propagation ratio is more effected by strength of welding materials than endurance limit of welding materials according to welding methods.

  • PDF

Effect of Aging on fatigue of Al Clad INVAR Core Wire for High Capacity and Low Sag(STACIR/AW) Conductor ( 1 ) (경년열화가 가공송전선(STACIR/AW)용 강심소재 Al Clad Invar 강선의 피로에 미치는 영향 ( 1 ))

  • Kim Shang-Shu;Kim Byung-Geol;Hyun Suk-Kyu;Sin Goo-Yong;Lee Dong-Il;Min Byung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.91-99
    • /
    • 2006
  • Fatigue properties of INVAR/AW wires have been investigated under the heat exposure in order to ensure stable operation and to estimate life span of their power line. In the case of heat exposure for 10000 hr, fatigue life and limit increased. For further heat exposure, fatigue limit decreased due to the decrease in yield strength. The variation fatigue of strand wire was strongly dependent on its amplitude. Also, cracks in wires of 7 strands were caused by stress concentration at the outer surface and fretting between each wire during vibration.

Evaluation for Fatigue Life of Rubber Isolator for Vibration Characteristic on Automotive Cooling Module (진동 특성을 고려한 자동차 냉각모듈 방진고무의 내구성 평가)

  • Shim, Hee-Jin;Kim, Han-Chul;Kim, Jung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.350-355
    • /
    • 2008
  • A Rubber mount is widely used for mechanical parts or engineering materials. Especially, it plays an important role in reducing mechanical vibration due to cyclic loading. But, rubber mount is damaged due to the cyclic loading and resonance. Therefore, it is necessary to investigate evaluation of fatigue life considering vibration characteristics for rubber. In this study, a vibration fatigue analysis was performed and based on Power Spectral Density(PSD) and the stress-life curve and a result of frequency response analysis in the finite element method. The measured load history in experiment was transformed to PSD curve. The stress-life curve was obtained by nonlinear static analysis and fatigue test. In addition, frequency response analysis was conducted for mechanical part. In order to evaluate fatigue life of rubber mount, vibration fatigue test was conducted at the constant acceleration-level as well. Fatigue life was determined when the load capacity is reduced to 60% of its initial value. As a result, predicted fatigue life of rubber mount agreed fairly well with the experimental fatigue life.

  • PDF

Evaluation of Rotation Capacity of Steel Moment Connections ConsideringInelastic Local Buckling - Parametric Studies (비탄성 국부좌굴을 고려한 철골 모멘트 접합부의 회전능력에 대한 변수 연구)

  • Lee, Kyung Koo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.625-632
    • /
    • 2008
  • In the companion paper (Model Development), an analytical model estimating the available rotation capacity of fully restrained beam-column connections in special steel moment-resisting frames was proposed. In this paper, two limit states were considered as the connection rotation capacity criteria: (i) strength degradation failure when the strength falls below the nominal plastic strength due to the local buckling of the beam's cross-section and (ii) low-cycle fatigue fracture caused by plastic strain accumulation at the buckled flange after only a few cycles of high-amplitude deformation. A series of analyses are conducted using the proposed model with two limit states under monotonic and cyclic loadings. Beam section geometric parameters, such as flange and web slenderness ratios, varied over the practical ranges of H-shapedbeams to observe their effect on the rotation capacity and low-cycle fatigue life of pre-qualified WUF-W connections.

Biological Aspects of Fatigue (피로의 생물학적 측면)

  • Lee, Moon-Soo;Joe, Sook-Haeng
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.15 no.2
    • /
    • pp.65-72
    • /
    • 2007
  • Fatigue is a significant problem in health care. The relationship between chronic fatigue and psychiatric disorders has generated significant interest in recent years. Increased rates of psychiatric disorder among individuals with chronic fatigue have been reported. Fatigue may be defined as physical and/or mental weariness resulting from exertion. The cause of fatigue is complex, influenced by events occurring in both the periphery and the central nervous system. Because fatigue may result from a number of causes, it should be treated comprehensively. The treatment is largely symptomatic and rehabilitative.

  • PDF

Muscle Fatigue Analysis Based on Electromyography Signals for The Evaluation of Low-Level Laser Therapy (저출력 레이저의 치료 효과 규명을 위한 근전도 신호의 피로도 해석 연구)

  • Kim, Ji-Hyun;Choi, Hyo-Hoon;Youn, Jong-In
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.319-327
    • /
    • 2011
  • Skeletal muscle fatigue is defined as a 'any reduction in the maximal capacity to generate force or power output', and is the reduction of oxygen consumption and by-product of metabolism. For the muscle fatigue therapy, low level laser has been introduced that leads the mitochondrial respiratory and attributes the muscle fatigue recovery. This study analyzed the muscle fatigue signals from electromyography(EMG) during low-level laser therapy (LLLT). Healthy subjects performed voluntary elbow flexion-extension excercise and received placebo LLLT and active LLLT using a 830 nm laser diode. Then, EMG were measured for the evaluation of muscle fatigue. The acquired EMG data were analyzed with median frequency and short time fourier transform methods. The results showed that the LLLT had a significant symptomatic relief of muscle fatigue based on the EMG frequency analysis. Therefore, the muscle fatigue analysis with EMG signals can be applied to quantitative evaluation for the monitoring of LLLT effects.

Antioxidant and Anti-physical fatigue Effects of Polygonati Rhizoma and steamed Polygonati Rhizoma (황정(黃精)과 증숙 황정(蒸熟 黃精)의 항산화, 항피로 효능 비교 연구)

  • Kim, Jeong-Soo;Lee, AhReum;Roh, Seong-Soo;Kwon, OJun;Seo, Young-Bae
    • The Korea Journal of Herbology
    • /
    • v.31 no.3
    • /
    • pp.49-57
    • /
    • 2016
  • Objectives: Polygonati Rhizoma (PR) has containing the bioactive compounds such as poly sccharide A,B,C, oligosaccharide, amino acid, it has reported to anti-diabetes and hypertension, atherosclerosis. In this study, we were evaluates antioxidant and anti-physical fatigue effects of PR and steamed PR.Methods : The sample was divided into 5 groups-PR0 (PR without steaming process), PR1 (PR with once steaming process), PR3 (PR with third steaming process), PR6 (PR with sixth steaming process), PR9 (PR with ninth steaming process). We measured anti-oxidant activity through contents of polyphenol, flavonoid and DPPH, ABTS free radical scavenging capacity. And, anti-physical fatigue effect was evaluated using the swimming test, and the AMPK protein expressions in soleus muscle.Results : As a result, polyphenol, flavonoid, DPPH, ABTS free radical scavenging capacity of PR were increased as steaming times. Anti-physical fatigue effects by swimming test, PR0 have significantly increased, but steamed PR groups were decreased. The AMPK protein expressions of PR0 and PR1 groups were increased comparing with PR3, PR6 and PR9. All groups had effects on decreasing TG, creatine in blood serum, but had no effects on TC in blood serum.Conclusions : In conclusion, PR with 9 steaming process was more excellent than not-processed PR in anti-oxidant effect such as DPPH, ABTS radical scavenging activity and contents of polyphenol, flavonoid, but, not-processed PR increased swimming times than processed PR. These results suggest that processed PR has anti-oxidant effect as steaming times, and not-processed PR may be a novel potential anti-physical fatigue agents than processed PR.

An Experimental Study on the Fatigue Strength of Repair Welded Joints of Old Steel Bridge (신판교체 보수 용접부의 피로강도에 관한 실험적 연구)

  • Park Hyeon-Chan;Lee Jin-Hyeong;Kim Jae-Hwan;Jang Gap-Cheol;Jang Gyeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.94-96
    • /
    • 2006
  • Recently, steel structures have been increasing because of its brilliant features. In general, cracks and corrosion are produced due to the numerous environmental factors in steel structures. However, the validity of repair method for the damaged steel structures has not been fully verified because of its lack of safety and reliability after application. Moreover, repair method by welding inevitably involves cutting and welding processes and reliability for the safety during the processes has net been established yet. Therefore, this study carried out experiments on the fatigue strength of repair welded joints of old steel bridge to investigate the fatigue characteristics in the repair welded joints. Fatigue tests were conducted by 250kN capacity MIS with the frequency of 5Hz under amplitude loading. From the results, it is known that fatigue strength grade of the repair welded joints was satisfied with C grade which specification requires.

  • PDF