• Title/Summary/Keyword: fast response time

Search Result 839, Processing Time 0.027 seconds

MEASUREMENT OF $CO_2$ CONCENTRATION AND A/F RATIO USING FAST NDIR ANALYZER ON TRANSIENT CONDITION OF SI ENGINE

  • Lee, S.W.;Kim, W.S.;Lee, J.H.;Park, J.I.;Yoo, J.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.4
    • /
    • pp.385-390
    • /
    • 2006
  • A fast response $CO_2$ analyzer has been developed to study transient characteristics on an SI engine. The analyzer has the delay time of 4.5 ms and time constant of 2.8 ms, which is fast enough to measure $CO_2$ concentration on a transient condition. Wide range of A/F(Air/Fuel) ratio can be estimated using the analyzer with an additional switch type oxygen sensor. The results of measurement of $CO_2$ concentration and A/F ratio on a transient condition including rapid acceleration/deceleration and EGR(Ehxaust Gas Recirculation) on/off are presented and compared with a commercial exhaust gas analyzer and UEGO(Universial Exhaust Gas Oxyzen) sensor.

Development of Fast Response Time (16msec) in IPS Mode

  • Lim, C.S.;Lee, J.H.;Oh, C.H.;Choi, H.C.;Lee, Seung-Eun;Jin, Min-Ok;Klasen-Memmer, M.;Tarumi, K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.68-71
    • /
    • 2003
  • To be able to show moving images without visual problems like blurring and tailing, the response time of liquid crystal display (LCDs) must be improved. In this paper we will discuss our progress in improving the response time by optimizing the cell configuration and the use of new liquid crystal mixtures. A 20.1inch diagonal UXGA IPS TFT-LCD has been developed having a response time as fast as l-frame time (16msec) for white-black operation and less than 16msec in all gray levels without applying ODC (Over Driving Circuit). This is very important because one of the technology to reduce motion blurring, the use of scanning backlight is conditioned by 16msec for all grays. The excellent gray-to-gray response can be explained by virtue of fundamental characteristics of S-IPS mode and makes a good contrast with the results of VA mode.

  • PDF

A Experimental Study on the Response Time Characteristics of Actuator in the Hydraulic Control System (유압제어계통의 액추에이터 응답시간 특성변화에 관한 실험적 연구)

  • Lee, Joo-Seong;Lee, Kye-Bock
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • Response time of actuator in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary, Occasionally the appropriate response time is not easily determined. This study is on the characteristics of response time in the hydraulic system.

  • PDF

A Study on the Response Time Characteristics Related to Shock Control in the Hydraulic System Using the Fluid Device (유체기구를 이용한 유압계통의 충격치제어에 수반되는 응답시간 변화특성에 관한 연구)

  • Lee, Joo-Seong;Lee, Kye-Bock;Lee, Chung-Gu
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.597-603
    • /
    • 2001
  • Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.

  • PDF

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF

Fast Response Driving of TFT LCD for Motion Picture

  • Choi, Yu-Jin;Mo, Soon-Hee;Bae, Young-Min;Lim, Young-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.449-451
    • /
    • 2002
  • We reported the algorithm of driving scheme that enhances moving picture property by improving gray-to-gray response time. Here, we report result of simulation for estimation of driving voltage to reduce response time, and experimental result. We investigated optimization of algorithm so that minimum size of LUT can support to reducing the gray-to-gray response time within 1 frame period, and with single algorithm it is possible to apply the algorithm to various kinds of LC material. So in our system there is no external EEPROM.

  • PDF

A Study on the Associated Response Lag in Shock Control of Hydraulic System Using Fluid Device (유체기구를 이용한 유압계통의 충격치제어에 수탄되는 반응지연에 관한 연구)

  • Lee, Joo-Seong;Lee, Kye-Bock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1488-1495
    • /
    • 2002
  • The response time represents how fast a system responds to a given disturbance at the system boundary. Flow restricting devices for controlling transients can result in a decrease in the peakm pressure, but may change response time. Response lag in a hydraulic system leads to inefficient working cycle and operator discomfort. The experiments were conducted in order to get information on the parameters which exert appreciable influence on the response time. The experimental apparatu including a hydraulic actuator, orifice and a hydraulic pump was an idealization of a bucket hydraulic shifting system. Experimental results show that the response time depends on operating pressure and flow rate. The effects of orifice type and size on the response time are quantified.

Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier (3상 위상제어 정류기를 위한 DVR의 반응시간 최적화)

  • Park, Chul-Woo;Joung, Sookyoung;Ryu, Jee-Youl;Lee, Dae-Seup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.

Study on Electrically Controlled Birefringence Mode for Field Sequential Liquid Crystal Display (FSLCD용 ECB 모드 연구)

  • Kim, Seung-Jai;Oh, Sang-Min;Lee, Seung-Hee;Shin, Yong-Seop;Kim, Hyang-Yul;Kim, Seo-Yoon;Lim, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.563-566
    • /
    • 2004
  • We have studied a electrically controlled birefringence (ECB) mode for field sequential liquid crystal display (FSLCD). We measured response time of the ECB mode. The ECB mode exhibiting fast response time, high transmittance, low operating voltage and adequate viewing angle. The positive liquid crystal (LC) is better than negative LC on dielectric anisotropy, birefringence and rotational viscosity. So that, the ECB mode is one of strongest candidate for FSLCD application.

  • PDF

A Study on a Modified Minimum Time Position Control Algorithm Comfortably to be adapted for One-Chip Microcontroller (원칩 마이크로 콘트롤러에 사용하기 쉬운 수정된 최단시간 위치제도 알고리즘에 관한 연구)

  • Yang, Joo-Ho;Kim, Chang-Hwa
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.2
    • /
    • pp.97-108
    • /
    • 1994
  • The DC Servo Motor has been used as an actuator in automatic control fields because of the good response and the control easiness nevertheless it has some disadvantage such as spark at the brush. Recently, along with the fast development of semiconductor industries, the digital control scheme is increasing in comparison with analog control because of the strength against noise and the accuracy. In this paper, authors proposed a combined control algorithm, which is mixed Modified Minimum Time Position Control(MMTPC) and PI control algorithm. for minimum time position control of DC Servo Motor by the one-chip microcontroller. The proposed control algorithm showed the fast response and offset-free. The validity of the proposed method comparing with the VSS control is proved by the response experiments.

  • PDF