• Title/Summary/Keyword: fast response time

Search Result 839, Processing Time 0.037 seconds

Analysis of fast pressure control by the Ziegler-Nichols method for a transport module of a high vacuum cluster tool (고진공 클러스터 장비의 반송모듈에 적용된 Ziegler-Nichols 방법에 의한 고속 압력제어에 관한 해석)

  • 장원익;이종현;백종태
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.284-291
    • /
    • 1996
  • We have implemented a fast pressure control system for the transport chamber of a high vacuum cluster tool for advance semiconductor fabrication and evaluated its performance. To overcome the typically slow response of mass flow controllers, the modified experimental method is used very effectively to optimize the pressure control procedure. We successfully obtained quite fast pressure control by adjusting the starting time and eht tuning constants by the Ziegler-Nichols method. In the transport pressure $10\times 10^{-5}$ torr, actual pressure control starts from 4 sec after an initial gas load of 2.1 sccm. As a result, optimum conditions for the tuning constants are the rise rate of 0.02 torr/sec, the lag time of 0.15 sec, and the sampling period of 0.5 sec. Then the settling time is about 9 sec within about $\pm$0.5% for the referenced value. This settling time is enhanced above 75 percents in comparison with conventional experimental method. To account for the experimental effects observed, a theoretical model was developed. This experimental result has a tendency to fit with the theoretical result of $\omega$=-1.0.

  • PDF

Development of SDI Signal generator for Large size TFT-LCD (대형 TFT-LCD용 SDI 신호 생성기의 개발)

  • Choi, Dae-Seub;Sin, Ho-Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.13-16
    • /
    • 2014
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive TN-LCD like CRT. We made articulate images by fast refreshing images, and we realized the ratio of refresh time by counting between on time and off time for video signal input during 1 frame (16.7ms). Conventional driving signal cannot follow fast on-off speed, so we evaluated new signal generator using SDI (Serial Data Interface) mode signal generator. We realized articulate image generation similar to CRT by high fast full HD (High Definition) signals and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

Development of Seismic Analysis Model and Time History Analysis for KALIMER-600 (KALIMER-600 지진해석모델 개발 및 시간이력 지진응답해석)

  • Koo, Gyeong-Hoi;Lee, Jae-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.73-86
    • /
    • 2007
  • In this paper, a simple seismic analysis model of the KALIMER-600 sodium-cooled fast reactor selected to be the candidate of the GEN-IV reactor is developed. By using this model, the seismic time history analysis is carried out to investigate the feasibilities of a seismic isolation design. The developed simple seismic analysis model includes the reactor building, reactor system,, IHTS piping system, steam generator, and seismic isolators. The dynamic characteristics of the simple seismic model are verified with the detailed 3-dimensional finite element analysis for each part of the KALIMER-600 system. By using the developed simple seismic model, the seismic time history analyses for both cases of a seismic isolation and non-isolation design are performed for the artificial time history of a SSE (Safe Shutdown Earthquake) 0.3g. From the comparison of the calculated floor response spectrum, it is verified that the seismically isolated KALIMER-600 reactor building shows a great performance of a seismic isolation and assures a seismic integrity.

A Fuzzy Controller for Robust Control of Induction Motor Drive System (유도전동기 드라이브 시스템의 강인성 제어를 위한 퍼지 제어기)

  • 정동화
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.108-113
    • /
    • 1999
  • This paper presents a study on fuzzy speed and flux controller used in a vector control of a CRPWM(Current Ragulated PWM) induction motor drive. In this paper, an approach for an easier design of the fuzzy controller is presented in order to obtain the desired value for the response time with minimal overshoot and to improve the steady state performance for speed step commands. The fuzzy controller is constructed only upon the knowledge of the motor behaviour and the desired speed response, and provides fast and robust control by reducing the effects of nonlinearities, parameter changes and load disturbance. The results of applying the fuzzy logic controller to an IM drive system are compared with those obtained by application of a conventional PI controller. The fuzzy controller provided a better response than the PI controller.

  • PDF

Double DOF control of an electromechanical integrated toroidal drive

  • Xu, Lizhong;Liu, Xin
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.115-131
    • /
    • 2007
  • The electromechanical integrated toroidal drive is a new drive system. For the control of the drive, the torque fluctuation and the steady-state errors should be removed and the fast response to the input change should be achieved. In this paper, the torque fluctuation of the drive system is analyzed and expressed as Fourier series forms. The transfer function of the torque control for the drive system is derived from its electromechanical coupled dynamic equations. A 2-DOF control method is used to control the drive system. Using definite parameter relationship of the 2-DOF control system, the steady errors of the torque control for the drive system is removed. Influences of the drive parameters on the control system are investigated. Using proper drive parameters, the response time of the control system is reduced and the quick torque response of the drive system is realized. Using a compensated input voltage, the torque fluctuation of the drive system is removed as well. The compensated input voltage can be obtained from the torque fluctuation equation and the transfer function. These research results are useful for designing control system of the new drive.

Improved Vertically-Aligned Nematic Mode for High Performance Displays

  • Jhun, Chul Gyu;Gwag, Jin Seog
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.783-787
    • /
    • 2014
  • This paper presents an improved vertical alignment nematic liquid crystal mode characterized by the protrusions or slits of the top substrate and additional stripe type common electrodes with polarity switching of the bottom substrate to improve multi-domain vertically aligned (MVA) and patterned vertically aligned (PVA) nematic modes. MVA and PVA modes have disadvantages such as an LC disclination in the vicinity of the middle region of electrodes between the top and bottom protrusions in MVA mode or the top and bottom slits in PVA mode. Therefore, the stripe type common electrode generating a horizontal electric field and the protrusion or slit producing some pretilt of liquid crystals (LCs) were used to improve the LC disclination, which influences the transmittance and response speed. The simulation results showed that the proposed VA mode has higher transmittance than the MVA and PVA modes. As a result, the proposed VA mode can improve the response speed and transmittance remarkably, which makes it useful for upgrading the LCD display quality.

A Study on the Adaptive Friction Compensator Design of a Hydraulic Proportional Position Control System (유압 비례 위치제어시스템의 적응 마찰력 보상기 설계에 관한 연구)

  • 이명호;박형배
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.77-83
    • /
    • 2003
  • This paper deals with a position control problem of a hydraulic proportional position control system using a nonlinear friction compensation control. As nonlinear friction, stiction and coulomb friction forces are considered and modeled as deadzone and external disturbance respectively. In order to compensate this nonlinearities, we designed the controller which is the adaptive friction compensator using discrete time Model Reference Adaptive Control method in this paper. Digital Signal Processing board is employed for data acquisition and manipulation. The experimental results show that response is slow and steady-state error cannot be compensated properly without friction compensation but this compensator is effective to obtain fast response and good steady-state response.

Tension Control of a Wire Cut Discharge Machine Using ER Brake (ER 브레이크를 이용한 와이어 방전가공기의 장력제어)

  • Kim Key-Sun;Cho Myung-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.24-29
    • /
    • 2004
  • This paper presents the tension control of a wire-cut discharge machine using electrorheological(E,R) fluid based brake system. On the basis of the tension level required in the machine, an appropriate size of the ER brake which features design simplicity, fast response and salient controllability is designed. Considering the Bingham property of ER fluid and actuator response time, the governing equation of the ER brake is derived. And a tension propagation of wire electrode is modeled via frequency response. The tension control performance of the discharge machine is simulated by using a robust sliding mode controller.

Electric energy saving system with high speed response to load variation using power-factor correction (부하변동에 속응하는 역률개선형 전력절감시스템)

  • Kim, Tae-Soo;Kang, Hyung-Sik;Joo, Kyung-Don;Lyu, Seung-Heon;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2388-2390
    • /
    • 2002
  • Small type electric energy saving system is proposed in this paper. The system improves power factor fastly according to load variation of each customer. Phases of voltage and current are detected as 1[ms] unit. Phase coincident algorithm is applied for power factor improvement. Capacitance is controlled for optimal power factor correction. Series reactor is controlled for harmonics reduction. Non-contact device is used for fast response and long life. Test result shows the effect of this system. Power factor of 40[W] electric fan is improved from 95[%] to 100[%]. In the case of electric light, power factor is improved from 82[%] to 100[%]. Response time for load variation is less than 1[ms].

  • PDF

Optically isotropic liquid crystal composite incorporating with in-plane electric field geometry

  • Yamamoto, Shin-Ichi;Haseba, Yasuhiro;Iwata, Takashi;Higuchi, Hiroki;Choi, Suk-Won;Kikuchi, Hirotsugu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1593-1595
    • /
    • 2009
  • We demonstrate an intriguing liquid crystal display (LCD) mode that comprises an optically isotropic liquid crystal (LC) composite incorporating with inplane electric field geometry. No surface treatment, such as rubbing, is required to fabricate the LCD mode because it is based on an optically isotropic state. The measured response time was of submillisecond order. The LCD mode has several unique features such as fast response, continuous grayscale capability, and a high contrast ratio.

  • PDF