• 제목/요약/키워드: fast ion

검색결과 318건 처리시간 0.025초

DEVELOPMENT OF A NEW ION TRANSPORT CODE FOR PLANETARY IONOSPHERES WITH EXPLICIT TREATMENT OF ION-ION COLLISION

  • KIM YONG HA
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.59-66
    • /
    • 2005
  • A new ion transport code for planetary ionospheric studies has been developed with consideration of velocity differences among ion species involving ion-ion collision. Most of previous planetary ionosphere models assumed that ions diffuse through non-moving ion and neutral background in order to consolidate continuity and momentum equations for ions into a simple set of diffusion equations. The simplification may result in unreliable density profiles of ions at high altitudes where ion velocities are fast and their velocity differences are significant enough to cause inaccuracy when computing ion-ion collision. A new code solves explicitly one-dimensional continuity and momentum equations for ion densities and velocities by utilizing divided Jacobian matrices in matrix inversion necessary to the Newton iteration procedure. The code has been applied to Martian nightside ionosphere models, as an example computation. The computed density profiles of $O^+,\;OH^+$, and $HCO^+$ differ by more than a factor of 2 at altitudes higher than 200 km from a simple diffusion model, whereas the density profile of the dominant ion, $O_2^+$, changes little. Especially, the density profile of $HCO^+$ is reduced by a factor of about 10 and its peak altitude is lowered by about 40 km relative to a simple diffusion model in which $HCO^+$ ions are assumed to diffuse through non-moving ion background, $O_2^+$. The computed effects of the new code on the Martian nightside models are explained readily in terms of ion velocities that were solved together with ion densities, which were not available from diffusion models. The new code should thus be expected as a significantly improved tool for planetary ionosphere modelling.

FAST CHARGING STRATEGY FOR LITHIUM ION BATTERY

  • Hoang, Thi Quynh Chi;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.70-71
    • /
    • 2014
  • In this paper, an advanced charging strategy for improving the charging performance of the Li-ion polymer battery is proposed, which is based on the battery characteristic. Simulation results show that the proposed charging current pattern can improve the charging speed of battery in comparison with the standard CC-CV (constant current - constant voltage) charging strategy and the pulse-charging strategy.

  • PDF

Petroleomic Characterization of Bio-Oil Aging using Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry

  • Smith, Erica A.;Thompson, Christopher;Lee, Young Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.811-814
    • /
    • 2014
  • Bio-oil instability, or aging, is a significant problem for the long-term storage of fast pyrolysis oils. We investigated bio-oil aging at the molecular level using Fourier-transform ion cyclotron resonance mass spectrometry. Petroleomic analysis suggests that bio-oil aging is resulted from the oligomerization of phenolic lignin products whereas 'sugaric' cellulose/hemicellulose products have negligible effect.

Magnetic Reconnection and the Substorm

  • Min, Kyoung-Wook
    • 천문학논총
    • /
    • 제2권1호
    • /
    • pp.13-20
    • /
    • 1985
  • Magnetic reconnect ion is studied numerically by means of a two dimensional MHD code. The initial magnetic field configuration is the two-dimensional dipole field, and the simulation model involves magnetic reconnect ion driven by the magnetized plasma flow. Strong plasma jetting, plasmoid formation and its fast ejection are observed in the downstream region. The dependence of reconnection rate on the incoming energy flux is found to be very sensitive, while the magnitude of the resistivity does not influence much on the reconnection rate. The simulation results are discussed in the context of the geomagnetic substorm.

  • PDF

이온주입용 정밀고압 발생장치 연구 (A Study of Precision High Voltage Generator for Ion Injection)

  • 유동욱;정창용;백주원;조정구;조기연;김학성;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.158-161
    • /
    • 1998
  • A precision high voltage generator for ion injection is implemented on HFZVS-PSCI (High Frequency Zero-Voltage-Switching Phase-Shift-Controlled Inverter). Some practical aspects of implementing precision high voltage generator with HFZVS-PSCI, such as a HFHV transformer, multiflier, and precision CR divider are discussed. The results show that the generator under the Phase-Shift-Controller has a fast dynamic response, low ripple voltage, and high accuracy.

  • PDF

Tribenzylamine Ionophore를 이용한 pH-ISE의 제조 및 임상응용 (Preparation and Clinical Application of pH-ISE(Ion Selective Electrode) Based on Tribenzylamine Ionophore)

  • 조동회;박정오
    • 대한임상검사과학회지
    • /
    • 제38권1호
    • /
    • pp.59-64
    • /
    • 2006
  • The pH-ISE(ion selective electrode) based on tribenzylamine as a hydrogen ion carrier was prepared and its electrochemical characterization was studied. It responded linearly to hydrogen ions in the range of pH 3.1 - pH 11.0 and the Nernstian slope showed 55.0 mV/pH (at $20{\pm}0.2^{\circ}C$), it also showed a fast response time of 8 sec. When it was directly applied to human blood(pH 6.0-8.5), we could get the same satisfying results. A good reproducibility and stability were shown with the precision of 2 mV (${\pm}0.1$). The pH-ISE based on tribenzylamine exhibited biocompatibility in clinical applications.

  • PDF

보염기에 의해 안정되는 난류확산화염의 연소특성에 관한 연구 (A Study on the Combustion Characteristics of Turbulent Diffusion Flame Stabilized by Bluff Body)

  • 안진근;송규근
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.71-78
    • /
    • 1998
  • The flame stabilization and the combustion characteristics of diffusion flame formed in the wake of a cylindrical bluff body with fuel injection are studied. With the turbulence generator, the flame stability limits and ion currents were measured and analyzed. The results from this experimental study are summarized as follows. The region with highest average value of ion currents in the middle of flame is moved to the upstream side by the turbulent components of main stream. The flame mass with partially active reaction is moved fast for uniform flow and turbulence generator G3, but the flame mass with relatively slow reaction is moved slowly for turbulence generator G1. If the turbulence generator with strong turbulent component is installed, the turbulent time scale is increased with movement from main stream side to recirculation zone as well as the flame stability limits is deteriorated. Though the special dominant frequency is not appeared in the eddy which exists in flame, high frequency characteristics are appeared in uniform flow and turbulence generator G3, and low frequency characteristics are appeared in uniform flow, turbulence generator G3 and G1.

  • PDF

Experimental and simulation study on the backstreaming positive ions on the quarter-size negative ion source for CRAFT NNBI test facility

  • Yongjian Xu;Yuwen Yang;Jianglong Wei;Ling Yu;Wen Deng;Rixin Wang;Yuming Gu;Chundong Hu;Yahong Xie
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.546-551
    • /
    • 2024
  • As an effective methods of plasma heating, neutral beam injection (NBI) systems based on negative hydrogen ion sources will be utilized in future magnetic-confinement nuclear fusion experiments. Because of the collisions between the fast negative ions and the neutral background gas, the positive ions are inevitable created in the acceleration region in the negative NBI system. These positive ions are accelerated back into the ion source and become high energy backstreaming ions. In order to explore the characters of backstreaming ions, the track and power deposition of backstreaming H+ beam is estimated using the experimental and simulation methods at NNBI test facility. Results show that the flux of backstreaming positive ions is 1.93 % of that of negative ion extraction from ion source, and the magnet filed in the beam source has an effect on the backstreaming positive ions propagation.

이온빔 배향에 의한 수직 배향막의 액정 배향 (Vertical Alignment of Liquid Crystal by Ion Beam Irradiation)

  • 강동훈;김병용;김영환;옥철호;한정민;김종환;이상극;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.414-414
    • /
    • 2007
  • In this study, Liquid Crystal (LC) alignment and tilt angle generation in Nematic Liquid Crystal (NLC) with negative dielectric anisotropy on the homeotropic PI surface with new ion beam exposure are reported. Also. high density of ion beam energy (DuoPIGatron type Ar ion gun) is used in this study. The tilt angle of NLC on the homeotropic Polyimide (PI) surface for all incident angles is measured about 38 degree and this has a stabilization trend. And the good LC alignment of NLC on the PI surface with ion beam exposure of $45^{\circ}$ incident angle was observed. Also the tilt angle of NLC on the homeotropic PI surface with ion beam exposure of $45^{\circ}$ had a tendency to decrease as ion beam energy density increase. The tilt angle could be controlled from verticality to horizontality. Also, the LC aligning capabilities of NLC on the homeotropic PI surface according to ion beam energy has the goodness in case of more than 1500 eV. Finally. the superior LC alignment thermal stability on the homeotropic PI surface with ion beam exposure can be achieved. For OCB(Optically Compensated Bend) mode driving, we can need pretilt angles control for fast response time. In this study, We success pretilt angles control. Consequently, this result can be applied for OCB mode.

  • PDF

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권2호
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.