• Title/Summary/Keyword: fan coil unit

Search Result 36, Processing Time 0.034 seconds

Performance Test of a Fan Coil with an Oval-Type Heat Exchanger (타원관 열교환기를 적용한 팬코일 성능 시험)

  • Yoon, Jeadong;Lee, Seunghyun;Sung, Jeayong;Lee, Myeong Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • In this study, a fan coil unit with an oval-type heat exchanger has been developed. The performance of the present fan coil unit has been investigated, by comparison with the previous fan coil unit with a circular-type heat exchanger. For the fan coil unit with circular- and oval-type heat exchangers, the heat flux and pressure loss through the heat exchangers were measured at standard operating conditions. In addition, the wind speeds exhausted from the fan coil units were compared, for the same fan motor operation. The experimental results show that the average wind speed of the oval-type heat exchanger is 20 percent higher than that of the circular-type heat exchanger. The heat flux in the oval-type heat exchanger is enhanced by 40% or more, over the circular-type heat exchanger.

Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit (환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가)

  • Han Chang-Woo;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.

A Study on Performance Enhancement of AHU with a Pressure Type Fan (압입식 송풍방식을 적용한 AHU의 성능 향상을 위한 연구)

  • Jang, H.S.;Kim, E.P.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1164-1169
    • /
    • 2008
  • The miniaturization of the Air Handling Unit (AHU) has become an actual need because of the restriction of the using space on the vessel. In modern AHU’s construction, in which the fan section is at the end part of the ship, it’s very difficult to select a suitable capacity of evaporators, because the fan motor emits heat. Thus, the AHU structure has been changed as the fan section has been set before the cooling coil to get temperature values similar to the designed amount. Also, the air guider is installed in order to maintain equal air distribution after it passed the fan section. So, it is possible for air to equally pass the cooling coil. It is investigated three different geometries to find the best performance. Also, It is compared with the numerical and experimental results. The study found the case 3 gives the best results. The results of this study show the possible application of the new design.

A Study on the Flow Characteristics around Cooling Tubes of Fan Coil Unit for Ship (선박용 팬코일장치 냉각관 주위의 유동특성에 관한 연구)

  • Bae, Bong-Gap;Choi, Keom-Ran;Ro, Byeong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.151-156
    • /
    • 2009
  • This experimental study investigated in to the flow characteristics around staggered cooling tube arrays of fan coil unit for ship. A particle image velocimetry technique was employed to obtain detailed measurements at inlet-velocity-based Reynolds numbers of $Re=1.5{\times}10^3{\sim}Re=2.5{\times}10^3$. As for the results, the flow evolves rapidly and becomes spatially periodic in the streamwise direction after a relatively short distance. The flow exhibits strong Reynolds number dependence in developing region but no significant Reynolds number effects are observed in spatially periodic region.

  • PDF

Experimental Study on Heat Transfer and Pressure Drop of Heat Exchangers for Cooling Fan Coil Unit (냉방용 팬코일 유닛 열교환기의 열전달 및 압력강하 특성 실험연구)

  • Kwon, Young-Chul;Ko, Kuk-Won;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.599-604
    • /
    • 2008
  • An experimental study has been performed to investigate the air-side capacity and pressure drop of the fin-tube heat exchanger for a fan coil unit under a cooling condition. The experimental data of five kinds of slit fin-tube heat exchangers were measured using an air-enthalpy calorimeter and a constant temperature water bath. Cooling capacities at the air and water rating flow rates were larger at the lower inlet water temperature. With increasing the water flow rate, the cooling capacity increased at the constant rate. Under the lower inlet water temperature, since the condensate was generated more on the fin-tube surface, the air-side pressure drop of the heat exchanger was larger.

Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient (타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향)

  • Yoon, Jaedong;Lee, Younghoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.

A study on the design of air conditioning system in the mushroom cultivation greenhouse (버섯재배사의 공조시스템 설계에 대한 연구)

  • Ryu, Kyung-Jin;Son, Jae-Hwan;Han, Chang-Woo;Nah, Kyu-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.743-750
    • /
    • 2017
  • It is important to ensure a uniform temperature distribution in greenhouses for the mushroom cultivation. The air temperature of the mushroom cultivation greenhouse is made uniform by supplying a constant air temperature with the underground air. The mushroom cultivation array in a greenhouse in seven columns and four rows can make smooth air flows between the rows and prevent air differences between the top and bottom. The buoyancy effect in the entering air of 0.5m/s based on following density difference depending on initial internal temperature needs to be considered. The locations of the Fan Coil Unit (FCU) and fan were defined through flow analysis in a greenhouse to distribute the optimal uniform temperature. In this study, the air conditioning system of a greenhouse with a sandwich heat insulting panel shape which is composed of a FCU and fan was designed by flow analysis. A relatively uniform temperature distribution can be formed because the circulation path of air becomes longer in the different locations of the FCU (inlet) and fan (outlet) through the internal temperature and flow analysis. The cultivation and quality uniformity of the mushrooms could be promoted through these environmental improvements.

Control Characteristics with Flow Rate Control Methods in Central Heating System (중앙난방시스템의 유량제어방식에 따른 제어특성 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

항균처리를 한 공조기기의 항균성능 평가방법과 평가결과

  • Miura, Kunio;Takatsuka, Takesi;Yanagi, U;Yamazaki, Shoji
    • Air Cleaning Technology
    • /
    • v.22 no.2
    • /
    • pp.40-49
    • /
    • 2009
  • Aluminum thin plate coated with epoxy resin containing about 20wt% brass powder, was applied to fins of heat exchanger. We carried out a series of detailed examinations to evaluate the anti-bacterial performance of the plate and heat exchanger (fan coil unit). In the presence of water or moisture, copper ions which have an anti-bacterial ability eluted from brass powder and showed sufficient effects on many kinds of bacteria. We also evaluated the anti-bacterial performance quantitatively by use of the index API (Anti-bacterial Performance Index) which has already been proposed by authors.

  • PDF