• Title/Summary/Keyword: failure zone

Search Result 577, Processing Time 0.036 seconds

A Study on Glass-Infiltrated Alumina and Spinel Composite I. Effect of Microstructure and Glass Content on Contant Damage and Strength (유리침윤 알루미나 및 스핀넬 복합체에 관한 연구 I. 미세구조 및 유리함량이 접촉손상 및 강동에 미치는 영향)

  • 정연길;최성철
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.7
    • /
    • pp.671-678
    • /
    • 1998
  • Hertzian indentation tests with sphere indenters were used to study the mechanical properties of glass-in-filtrated alumina and spinel composites and evaluated the effect of preform microstructure and evaluated the effect of preform microstructure and glass con-tents on contanct damage and strength. The spinel composite showed more brittle behavior than the alumina composite which is verified from indentation stress-strain curve cone cracks and quasi-plastic deformation developed at subsurface. Failure originated from either cone cracks(brittle mode) or deformation zone(quasi-plastic mode) above critical load for cracking(Pc) and yield ({{{{ {P }_{Y } }}) with the brittle mode more dominant in the spinels and the quasi-plastic mode more dominant in the aluminas. Even though brittle mode was dominant in the spinel composites the strength degradation from accumulation of damage above these critical loads was conspicuously small suggesting that the glass-infiltrated composites should be highly damage tolerant to the blunt contacts.

  • PDF

Effect Evaluation of Hole Defects in Adhesive on SIF of Interface Crack (접착층내 결함이 계면균열의 응력확대계수에 미치는 영향 평가)

  • Hyun, Cheol-Seung;Heo, Sung-Pil;Yang, Won-Ho;Ryu, Myung-Hae
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.299-303
    • /
    • 2001
  • Adherend-adhesive interface failure will occur on a macroscale when surface preparation or material quality are poor. It is well known that the stress singularity occurs at the edges of interface between the adhernds and the adhesive, and that crack will initiate from these positions. Also if bubbles are created and remained in the adhesive layer during the bonding process, the stress concentrates around these hole defects. In this paper, the effects of the hole defects on the SIF of interface crack were examined. From results, SIF increased with the hole defects near the interface crack and increased with an decreae in the upper adherend thickness, an increase in the center adhesive thickness.

  • PDF

A study of ballistic impact energy absorbing mechanism of composites (복합재료의 방탄충격에너지 흡수에 관한 연구)

  • 강은영;윤영기;황도인;윤희석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.773-776
    • /
    • 1997
  • This paper presents an investigation of the energy absorption of composite laminates during ballistic impact. Three components are responsible for the absorption of energy-the tensile failure of fiber, the elastic deformation of the composite, the delamination of composite laminates. The ballistic limit, V/sub 0/, of the laminates is determined using a previous model implemented to determine the energy absorption of the three components listed above. The size of the deformed zone during impact was estimated by an approximate solution for impacts on plates. The carbon/epoxy plates were examined for this research.

  • PDF

A Fundamental Study on the Workability of High Strength Concrete according to Kinds of Aggregate (골재의 종류에 따른 고강도 콘크리트의 시공 특성에 관한 기초적 연구)

  • 최희용;김규용;최민수;김진만;심옥진;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.12-17
    • /
    • 1996
  • It is true that aggregate strength is usually not a factor in normal concrete strength because, the aggregate particle is several times stronger than the matrix and the transition zone in concrete. In other words, with most natural aggregates the strength of the aggregate is hardly utilized because the failure is determined by the other two phases. But aggregate characteristics that are significant to concrete technology include porosity, grading or size distribution, moisture absorption, shape and surface texture, crushing strength, elastic modulus, and the type of deleterious substances present. Therefore, in the area of high strength concrete, concrete is much more influenced by properties of aggregate. This experiment is performed to investigate how kinds of aggregare influence on the workability of high strength concrete. In this experiment, four types of aggregate is used, that is crushed river aggregate, crushed stone, recycled aggregate of low strength and recycled aggregate of high strength. In this study, we scrutinize a fundmental study on the workability of high strength concrete according to kinds of aggregate.

  • PDF

Flexural Behavior of Slab Repaired and Rehabilitated with Strand and Polymer Mortar (강연선과 폴리머 모르터에 의해 보수ㆍ보강된 슬래브의 휨거동 특성)

  • 황정호;양동석;박선규;엄준식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1007-1012
    • /
    • 2003
  • With deterioration of the nation's infrastructure comes the growing, need for effective means of rehabilitating structures. Possibly one for the most challenging tasks is to upgrade the overall capacity of concrete structure. This study focused on the flexural behavior of reinforced concrete slabs strengthened by PS strand and polymer mortar in the tension zone. The properties of slabs are 70×12㎝ rectangular and over a 220㎝ span. Test parameters in this experimental study were placing thickness, chipping, the number of strand, the kind of mortar. Attention is concentrated upon overall bending capacity, deflection, ductility index, failure mode and crack development of repaired and rehabilitated slabs.

  • PDF

Behavior of Steel Beam-High Strength Concrete Column Joint Subjected to Cyclic Loadings (철골보-고강도 콘크리트 기둥 접합부의 거동에 관한 연구)

  • Shin, Sung-Woo;Lee, Kwang-Soo;Seo, Seon-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.205-210
    • /
    • 2000
  • The objective of this study is to investigate the structural behavior of steel beam-high strength concrete column joints subjected to reversed cyclic loadings. The variables of the experimental study is amount of steel plates at the beam-to-column joint panel zone. Three specimens were prepared and tested under constant uniaxial load($0.2f_{ck}A_g$) to reinforced high strength concrete column, and the reversed cyclic loads were applied to end of steel beams, The failure modes, hysteresis loop, stiffness degradations and energy dissipation capacities were analyzed and compared for test variables.

  • PDF

Seismic Response of Haunch Repaired Steel MRFs: A Case Study (헌치로 보강된 철골모멘트 골조의 지진 응답: 사례연구)

  • 이철호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.173-181
    • /
    • 1997
  • To investigate the effects of haunch repair on the system seismic performance of steel moment-resisting frames (steel MRFs), a case study was conducted for a 13-story frame damaged during the 1994 Northridge earthquake. It was assumed that only those locations with reported damage would be repaired with haunches. A new analytical modeling technique for the dual panel zone developed by the author was incorporated in the analysis. Both the inelastic static and dynamic analyses did not indicate detrimental side effects resulting from the repair. As a result of the increased strength in dual panel zones, yielding in these locations were eliminated and larger plastic rotation demand occurred in the beams next to the shallow end of the haunches. Nevertheless, the beam plastic rotation demand produced by the Sylmar record of 1994 Northridge earthquake was still limited to 1.7% radians. The repair resulted in a minor increase in earthquake energy input. In the original structure, the panel zones should dissipate about 80%(for the Oxnard record) and 70%(for the Sylmar record) of the absorbed energy, assuming no brittle failure of moment connections. After repair, the energy dissipated in the panel zones and beams were about equal.

  • PDF

DESIGN CONSIDERATION OF MULTIPACTOR PHENOMENA BASED ON S-BAND DIPLEXER FOR SATELLITE APPLICATIONS

  • Choi Seung-Woon;Kim Day-Young;Kwon Ki-Ho;Chae Tae-Byeong;Lee Jong-In
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.360-363
    • /
    • 2004
  • This review is concerned with the MP (multipactor) phenomena of the diplexer for RFDU DM of next generation satellite. The MP discharge is serious problems to design RF components in space applications such ase damage of physical structure, performance degradation, and mission failure of the satellite. In this work, we employed the 3D finite element method (FEM) to calculate the critical gap points and adopted ESTEC curve, MP susceptibility zone, to analyze the maximum handling RF power in the diplexer. And this work also recommends that one should design the tx filter of the diplexer which is more wider bandwidth upto the points to escape the ears of the group delay especially the cavity type of RF components in space applications.

  • PDF

A Study on Tube-to-Tube Similar Friction Welding of Rocket Motor Nozzle Material and its AE Evaluation (로켓모터용 노즐재의 관대관 마찰용접과 AE평가에 관한 연구)

  • Gong, Yu-Sik;O, Se-Gyu;Lee, Bae-Seop
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.66-73
    • /
    • 1999
  • This paper presents the experimental examinations and statistical quantitative analysis of the correlation between the cumulative counts of acoustic emission(AE) during plastic deformation periods of the welding and the tensile strength and other properties of the tube-to-tube welded joints of O.D. 30mm (I.D 18mm) nozzle steel. This is a new approach which attempts finally to develop real-time quality monitoring system for friction welding. And this study results in practical possiblility of real-time quality control more than 100% joint efficiency showing good weld no micro structural defects.

  • PDF

Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test (실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.