• Title/Summary/Keyword: failure testing

Search Result 1,208, Processing Time 0.029 seconds

XA and Non-XA Interface Methodology of an X/Open DTP-based Trading System in Finance Industry (X/Open DTP 기반 증권사 트레이딩 시스템에서의 XA/Non-XA 인터페이스 방법)

  • Kim, Yong-Tae;Byun, Chang-Woo;Park, Seog
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.5
    • /
    • pp.498-508
    • /
    • 2003
  • In the field of finance, Trading System of Securities is a very vulnerable application when it faces any small problems just for one minute. Since Trading System changes its environment from mainframes to client/server, its safety becomes the most important factor. Even though most If systems are configured by general guidelines currently, Trading System is an exception that it is configured by specific and rather ad hoc guidelines in order to ensure its safe management. In this thesis, I will prove the validity of specific and ad hoc configuration in the environment of Trading Systems where I use both XA interface system and Non-XA interface to configure its system based on 3-Tier Client/server computing environment through middleware, TP-Monitor, in the X/Open DTP Model. In order to validate the Trading System, I will compare and analyze the error of data of an order and ability to restore using both XA and Non-XA interfaces while testing take-over scenario on the assumption of the system's failure.

Effectiveness Analysis and Profile Design Automation Tool Implementation for The Mass Production Weapon System Environmental Stress Screening Test (양산 무기체계 환경 부하 선별 시험 효과도 분석 및 프로파일 설계 자동화 도구 구현)

  • Kim, Jang-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.379-388
    • /
    • 2016
  • There are various system defects from weapons manufacturing due to the numerous production processes and various production environments. The first kind of defect is patent defects, which can be detected by visual inspection, functional testing, and existing quality control procedures during the manufacturing process. The second kind is latent defects, which cannot be detected though existing quality management approaches because of the complexity of the system and manufacturing process. To minimize the initial defect problems, environmental stress screening (ESS) is needed to detect the defects, remove them, and improve the product conditions based on the environmental stress conditions of temperature and vibration. We implemented a tool for quantitative ESS effectiveness analysis and profile design automation based on MIL-HDBK-344 and verified it using six scenarios with different temperature stress, vibration stress, and test designs.

A Case of Influenza-associated Encephalopathy (인플루엔자 관련 뇌증 1례)

  • Song, Yeoni;Choi, Chang Hwan;Choi, Jong Woon;Kim, Se Young;Kim, Hyun Soo;Kim, Yeol;Im, Dong Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.1024-1028
    • /
    • 2003
  • Influenza-associated encephalopathy is regarded as one of the major neurologic disease entities along with those of Reye syndrome, acute necrotizing encephalopathy, and myelitis which are known to be related to influenza virus, mostly type A. And it is being actively researched in Japan as it has caused a tremendous increase in the number of deaths from 1997 to 2002, but it has not been yet reported in the Korean pediatric medical community. It attacks those previously healthy children, who have not been vaccinated. Patients start with such symptoms as fever and common respiratory problems, but within 24 to 48 hours they suffer from seizures with acute mental deterioration, become worse, and suffer multiple organ failures including marked elevated transaminase levels as well as coagulopathy. It induces deaths in a couple of days after the symptoms appear or remains a serious neurologic sequelae. Confirmative diagnosis is used to demonstrate influenza viral infection. We report here a 37 month aged boy who was admitted to our hospital during the last influenza season under the diagnosis of influenza associated encephalopathy on the basis of serologic testing by hemagglutinin inhibition(HI). This is the first report confirmed by increased antibody titer of the influenza A virus in Korea.

A STUDY ON FRACTURE STRENGTH OF CONVENTIONAL AND COPY-MILLED IN-CERAM CROWNS (Copy-milled Celay In-Ceram 전부도재관의 파절강도에 관한 연구)

  • Hwang, Jung-Won;Yang, Jae-Ho;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.417-430
    • /
    • 1997
  • The purpose of this study was to compare the fracture resistance of copy-milled and conventional In-Ceram crown. Four groups of ten uniform sized all-ceramic crowns were fabricated. In-Ceram Spinell and In-Ceram Alumina crowns were fabricated as control group, Celay In-Ceram Spinell and Celay In-Ceram Alumina crowns were fabricated as test group. All specimen were cemented on stainless steel master die with resin cement, and stored in $37^{\circ}C$ water for 1 day prior to loading in Instron testing machine. Using a steel ball at a crosshead surfed of 0.5mm/min, the crowns were loaded at $30^{\circ}C$ angle until catastrophic failure occurred. The results obtained were as follows : 1. With the value of $984.8N{\pm}103.67N$, the strength of Celay In-Ceram Alumina crowns had a significantly higher fracture strength than conventional In-Ceram Alumina crowns ($876.2N{\pm}92.20N$) (P<0.05) 2. The fracture strength of Celay In-Ceram Spinell crowns($706.3{\pm}70.59N$) was greater than that of conventional In-Ceram Spinell crowns($687.4{\pm}90.26N$), but there was no significant difference(P>0.05). 3. The In-Ceram Alumina crowns had a significantly higher fracture strength than In-Ceram Spinell crowns in both methods(P<0.05). 4. Ther order of fracture strength was as followed : Celay In-Ceram Alumina, In-Ceram Alumina, Celay In-Ceram Spinell and In-Ceram Spinell crowns

  • PDF

THE STUDY ON THE PHYSICAL PROPERTY OF THE PERMANENT SOFT DENTURE LINERS (영구 연성 의치상 이장재의 물리적 성질에 관한 연구)

  • Kim, Yeon-Mi;Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.809-818
    • /
    • 1999
  • This study was performed to evaluate the tensile bond strength and modulus of elasticity of three permanent soft denture liners (Molloplast $B^{(R)}$, Ufi Gel $C^{(R)},\;Tokuyama^{(R)}$) before and after thermocycling. And their water sorption were also evaluated. Each soft denture liner was bonded to PMMA denture base resin blocks and the tensile bond strength and modulus of elasticity were measured by using universal testing machine. For the water sorption, weight measured after immersion of sea denture liners in $37{\pm}1^{\circ}C$ water bath for 4 weeks. The results were as follows : 1. Molloplast $B^{(R)}$ had the highest tensile bond strength, while Tokuyama had the lowest tensile bond strength. There was no significant difference between $Tokuyama^{(R)}$ and Molloplast $B^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in tensile strength of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 2. For the modulus of elasticity, there was no significant difference between Ufi Gel $C^{(R)}\;and\;Tokuyama^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in modulus of elasticity of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 3 The failure modes of Molloplast $B^{(R)}$ and Ufi Gel $C^{(R)}$ were mainley adhesive type and that of $Tokuyama^{(R)}$ was mainly mixed type in case of nonthermocycling and cohesive type after thermocycling. 4. The water sorption of each soft liners was within ${\pm}2%$ in times (p<0.05) but. there was no significant difference among the soft liners in times.

  • PDF

Sensitivity analysis of serological tests for detection of disease in cattle (소 질병 검출을 위한 혈청학적 검사의 민감도 평가)

  • Lee, Sang-Jin;Moon, Oun-Kyong;Pak, Son-Il
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Animal disease surveillance system, defined as the continuous investigation of a given population to detect the occurrence of disease or infection for control purposes, has been key roles to assess the health status of an animal population and, more recently, in international trade of animal and animal products with regard to risk assessment. Especially, for a system aiming to determine whether or not a disease is present in a population sensitivity of the system should be maintained high enough not to miss an infected animal. Therefore, when planning the implementation of surveillance system a number of factors that affecting surveillance sensitivity should be taken into account. Of these parameters sample size is of important, and different approaches are used to calculate sample size, usually depending on the objective of surveillance systems. The purpose of this study was to evaluate the sensitivity of the current national serological surveillance programs for four selected bovine diseases assuming a specified sampling plan, to examine factors affecting the probability of detection, and to provide sample sizes required for achieving surveillance goal of detecting at least an infection in a given population. Our results showed that, for example, detecting low level of prevalence (0.2% for bovine tuberculosis) requires selection of all animals per typical Korean cattle farm (n = 17), and thus risk-based target surveillance for high risk groups can be an alternative strategy to increase sensitivity while not increasing overall sampling efforts. The minimum sample size required for detecting at least one positive animal was sharply increased as the disease prevalence is low. More importantly, high reliability of prevalence estimation was expected with increased sampling fraction even when zero-infected animal was identified. The effect of sample size is also discussed in terms of the maximum prevalence when zero-infected animals were identified and on the probability of failure to detect an infection. We suggest that for many serological surveillance systems, diagnostic performance of the testing method, sample size, prevalence, population size, and statistical confidence need to be considered to correctly interpret results of the system.

Low Cycle Fatigue Behavior of Alloy617 Weldment at 850℃ (850℃에서의 Alloy 617 용접재의 저사이클 피로 특성)

  • Hwang, Jeong Jun;Kim, Seon Jin;Kim, Woo Gon;Kim, Eung-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.193-198
    • /
    • 2017
  • Alloy 617 is one of the primary candidate materials to be used in a very high temperature reactor (VHTR) system as an intermediate heat exchanger (IHX). To investigate the low cycle fatigue behavior of Alloy 617 weldments at a high temperature of $850^{\circ}C$, fully reversed strain-controlled fatigue tests were conducted with the total strain values ranging from 0.6~1.5%. The weldment specimens were machined using the weld pads fabricated with a single V-grove configuration by gas tungsten arc welding (GTAW) process. The fatigue life is reduced as the total strain range increases. For all testing conditions, the cyclic stress response behavior of the Alloy 617 weldments exhibited the initial cyclic strain hardening phenomenon during the initial small number of cycles. Furthermore, the overall fatigue cracking and the propagation or cracks showed a transgranular failure mode.

Environmental Exposure Performance of a Panel-Type Glass-Fiber-Reinforced Polymer Composite Clamping Plate for an Improved Moveable Weir (개량형 가동보에 적용하기 위한 패널형 유리섬유보강 폴리머 복합재료 클램핑 플레이트의 환경노출 성능)

  • Yoo, Seong-Yeoul;Jeon, Jong-Chan;Shin, Hyung-Jin;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.73-81
    • /
    • 2017
  • The improved movable weir supplements the advantages and disadvantages of the rubber weir and the conduction gate. It consists of a stainless steel gate, air bags, and a steel clamping plate. The stainless steel gate is the main body of the weir, and the inflatable rubber sheet serves to support the steel gate. The steel clamping plate is typically in direct continuous contact with water, but this leads to corrosion issues that can reduce the life of the entire movable weir. In this study, a panel-type glass-fiber-reinforced polymer (GFRP) clamping plate was designed and fabricated. The test results showed that the flexural load of the panel-type GFRP composite clamping plate was over twice that of the wings type GFRP clamping plate. The lowest moisture absorption value was obtained upon exposure to tap water, and exposure to other solutions showed similar values. Additionally, flexural load testing after exposure to an accelerated environment found the lowest residual loads of 80.51 % and 78.50 % at 50 and 100 days, respectively, for exposure to a $CaCl_2$ solution, while exposure to other environments showed residual failure loads of over 80 % at both 50 and 100 days.

The Study for ENHPP Software Reliability Growth Model based on Burr Coverage Function (Burr 커버리지 함수에 기초한 ENHPP소프트웨어 신뢰성장모형에 관한 연구)

  • Kim, Hee-Cheul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.4
    • /
    • pp.33-42
    • /
    • 2007
  • Accurate predictions of software release times, and estimation of the reliability and availability of a software product require quantification of a critical element of the software testing process : test coverage. This model called Enhanced non-homogeneous poission process(ENHPP). In this paper, exponential coverage and S-shaped model was reviewed, proposes the Kappa coverage model, which maked out efficiency application for software reliability. Algorithm to estimate the parameters used to maximum likelihood estimator and bisection method, model selection based on SSE statistics and Kolmogorov distance, for the sake of efficient model, was employed. From the analysis of mission time, the result of this comparative study shows the excellent performance of Burr coverage model rather than exponential coverage and S-shaped model using NTDS data. This analysis of failure data compared with the Kappa coverage model and the existing model(using arithmetic and Laplace trend tests, bias tests) is presented.

  • PDF

Effect of Temperature and Thickness on Fracture Toughness of Solid Propellant (고체추진제의 파괴인성에 대한 온도 및 두께의 영향)

  • Seo, Bo Hwi;Kim, Jae Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1355-1360
    • /
    • 2013
  • A cracked solid propellant would have failure or fracture of rocket because of excessive combustion according to increase of burning area, therefore it is important to evaluate the fracture toughness of solid propellant. A procedure is used to investigate the material under a range of test temperatures between -60 and $60^{\circ}C$, three kind of specimen thickness, 4, 12.5 and 24.5 mm to determine the effect of two parameters on the fracture toughness. A center cracked tension (CCT) specimen is used in these tests, which were conducted using INSTRON 5567 testing machine and environmental chamber to evaluate the fracture toughness. The experimental results show that the fracture toughness tends to decreases with an increase in the temperature, and the effect of thickness indicates that the fracture toughness is highest at 12.5 mm under various temperatures except $-60^{\circ}C$. It is found that the fracture toughness of solid propellant is changed due to glass transition behavior around $-60^{\circ}C$.