• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.026 seconds

Characteristics of Insulation Diagnostic in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연진단 특성)

  • Kim, Hee-Dong;Kim, Chung-Hyo;Park, Young;Park, Hyun-June
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.336-338
    • /
    • 2006
  • Diagnostic tests are used to evaluate the insulation condition of stator windings in traction motor. These tests included ac current, tan delta and maximum partial discharge. The insulation condition of stator windings was assessed by three test items. The stator windings of traction motor were m good condition. After completing the diagnostic tests, the stator windings of traction motors were subjected to gradually increasing ac voltage, until the insulation punctured. No.5 stator windings failed near rated voltage of 18.9 kV. The breakdown voltage of No.1 stator windings was 13.0. The failure was located m a line-end coil at the exit from the core slot.

  • PDF

The Influence of Indentation on Rolling Contact Fatigue (구름 접촉피로에 미치는 압혼의 영향)

  • 이동엽;이한영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.74-79
    • /
    • 1997
  • Most of the results of recent research for the influence of indentation on rolling contact fatigue has been carried out with high strength material under the point contact. The plastic lug around the indent also has been known as a source of stress concentration. This study is undertaken to analyze the influence of indentation on rolling contact fatigue with low strength material under the line contact. The results in this study show that the plastic flow around indentation by rolling friction has a major influence, differed from the results of high strength material. And the change of residual stress and half-value breadth measured to the failure by X-ray diffraction can be identified to predict the rolling contact fatigue life of indented materials.

  • PDF

The On-Line Fault Detection and Diagnostic Testing of Systems using Neural Network (신경회로망을 이용한 시스템의 실시간 고장감지 및 진단 방법)

  • 정진구
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.147-154
    • /
    • 1998
  • As technical systems in building are being developed, the processes and systems get more difficult for the average operator to understand. When operating a complex facility, it is beneficial in equipment management to provide the operator with tools which can help in dicision making for recovery from a failure of the system. The main object of the study is to develop real-time automatic fault detection and diagnosis system for optimal operation of IBS building.

  • PDF

A Study on Physical Behavior Property of R/C Beams Strengthened with Bonding Methods (보강재의 부착방법의 따른 물리적 거동 특성에 관한 연구)

  • 한만엽;백승덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.727-732
    • /
    • 1999
  • In this research, we made an experiment on the 10 specimen beams that we made. The specimen beams consist of 4 steel plate strengthening beams and 5 carbon fiber sheet strengthening beams. We applied the methods of notch, rounding off a edge, anchor bolt and side shear strengening to the steel plate and for the case of carbon fiber sheet, we applied the methods of anchor bolt, line anchor and shear strengthening. After all the cases were applied, the beams was measured and analyzed about the behavior property of strengthened beams, th ability of strengthening method, the relation between load and the shape of failure, the crack load, the yield load, the shape of crack pattern, the increasing rate from yield load and maximum load and the strain of rebar. All the strengthening methods resulted in almost same value until the yield load, and it wasn't quite different from the theoretical value. In comparison with existing method, the SER, SEAS for the steel plate and the CEA, CESS, CCESS for carbon fiber sheet showed the increasement of ductility with big displacement.

  • PDF

Novel Structure of 21.6 inch a-Si:H TFT Array for the Direct X-ray Detector

  • Kim, Jong-Sung;Choo, Kyo-Seop;Park, June-Ho;Chung, In-Jae;Joo, In-Su
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.29-31
    • /
    • 2000
  • A 21.6" a-Si:H TFT array for direct conversion X-ray detector with 2480 by 3072 pixels is successfully developed. To obtain X-ray image of satisfactory quality, a novel structure with a storage electrode on BCB is proposed. The structure reduces the parasitic capacitance of data line, which is one of the main sources of signal noise. Also, the structure shows greater resistance to failure than that of the conventional design.

  • PDF

Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures (절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석)

  • Kim, Chang-Jong;Lee, Heung-Jae;Sin, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF

A Proposal of On-line Management Method for Distribution Transformer using Loss-of-life Calculation (수명 손실 계산을 이용한 온라인 배전용 변압기 관리 방안 제시)

  • Kim, Dong-Hyun;Kim, Jae-Chul;Choi, Joon-Ho;Kim, Oun-Seok;Yun, Yong-Han;Min, Kyeoung-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.61-63
    • /
    • 2000
  • As increasing the failure of distribution transformers, we need to manage them efficiently. This paper proposes the method for distribution transformer's management using loss-of-life calculation. The Data Acquisition System(DAS) was developed to manage transformers and the HDLC protocol applied to the system. It will be feasible application to diagnose distribution transformers by checking load conditions such as top oil temperature, ambient temperature, load current, etc. and using loss-of-life calculation.

  • PDF

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

Speckle Interferometric Detection of Defects on the backside of steel plate (스페클 간섭계를 이용한 평판 이면결함의 검출 특성)

  • 김동한;장석원;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.195-198
    • /
    • 2001
  • Backside defect of plate structure may grow due to fatigue or overload to cause critical failure during operation, so it is important to detect this kind of defect in line. For this purpose, nondestructive, non-contact and highly sensitive method is required. ESPI and Shearography are considered as useful method to satisfy these requirements. In this paper, the possibility of application of ESPI and Shearography to detect the backside defect of steel plate and to quantify the defect size was tested. For the experiment, some steel plates with defect on the backside were prepared. Experimental results for these plates showed that location and size of defect could be detected correctly by both of ESPI and Shearography.

  • PDF

The Evaluation of Thin Pressure Vessel′s Internal Defects by Laser Shearography (레이저 전단 간섭계를 이용한 압력용기의 내부 결함 평가)

  • 장경영;장석원;현민관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.929-933
    • /
    • 2003
  • Internal defects of thin pressure vessel used in the power plants or the chemical plants may be created and grow due to corrosion or creep fatigue to reduce the strength and cause critical failure during operation. Therefore it is very important to detect this defect at the early stage. For this purpose, non-destructive, non-contact and highly sensitive method should be considered for on-line application. In this paper, a laser shearographic interferometer is applied to inspect circular defects and notch defects existed inside of thin pressure vessel under the presence of pressure up to 3 times of atmospheric pressure. The influences of the defect shape and size as well as the internal pressure to the characteristic pattern in the shearography fringe are investigated, and the quantitative evaluation of the defect size is tried. Also the experimental results are compared with the destructive test results to show the applicability of this method to the quantitative evaluation of internal defects in the thin pressure vessel.

  • PDF