• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.025 seconds

Surgical Management of Aortic Insufficiency in Behcet`s Syndrome - An Experience of 8 Cases - (Behcet 씨 증후군에 의한 대동맥판 폐쇄부전의 수술치험 -3례 보고-)

  • 원용순
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.899-904
    • /
    • 1988
  • In Behcet syndrome, cardiac involvements are rare and have been reported pericarditis, myocarditis, right heart endocardial fibrosis, right ventricle mural thrombus with pulmonary embolism, active endocarditis, granulomatous endocarditis, conduction disturbance, acute aortic insufficiency, mitral valve prolapse. Our three patients underwent AVR because of aortic insufficiency and ascending aorta enlargement combined with Behcet syndrome. Two patients had mitral regurgitation too. So one underwent MAP and the other underwent MVR concomitantly. One who underwent AVR have been well for 50 months. Another who underwent AVR+MAP and redo AVR due to aortic paravalvular leakage was died of congestive heart failure. The other who underwent AVR+MVR and repeated AVR three times because of aortic paravalvular leakage is in condition of aortic paravalvular leakage. Paravalvular leakage is considered to recur due to progressive dilatation and fragility of aortic root that is the result of pathologic change of Behcet syndrome in it. If Open heart surgery is needed in Behcet`s syndrome during inflammatory reaction is active, postoperative complications such as paravalvular leakage or suture line rupture may be prevented with pre- and postoperative anti-inflammatory management.

  • PDF

황동볼트 손상원인 분석사례

  • Jeong, Nam-Geun
    • 열병합발전
    • /
    • s.30
    • /
    • pp.21-25
    • /
    • 2002
  • According to recent Korea Electric Power Company report, yearly distribution line brass cramp bolts failure summed up to 4,400 cases emerging as one of main local break-down causes. Naturally, the need for the investigation was proposed To determine the root cause of the cramp bolt failures, mechanical and metallurgical investigation were performed for 90 samples which collected from various sites. For the understanding of the geometric characteristics, stress distribution was evaluated by CAE program and proof load of each bolts was tested. The SEM&EDS was used for metallurgical investigation. Through the investigation, the root causes of failures were confirmed. All damaged bolts showed intergrannular fracture mode and the all fractured bolt showed ß phase morphology contrast to the a&ß mixture morphology of the non-damaged samples. Additionally, EDS analysis confirmed the existence of lead rich layer on grain boundaries.

  • PDF

Nonlinear Motion Responses of a Moored Ship beside Quay (안벽에 계류된 선박의 비선형 운동응답)

  • 이호영;임춘규;유재문;전인식
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.8-15
    • /
    • 2003
  • When a typoon sets into harbour, a moored ship shows erratic motions and even mooring line failure may occur. such troubles may be caused by harbour resonance phenomena, resulting in large motion amplitudes at low frequency, which is close ti the natural frequency of th moored ship. The nonlinear motions of a ship moored to quay are simulated under external forces due to wave, current including mooring forces in time domain. The forces due to waves are obtained from source and dipole distribution method in the frequency domain. The current forces are calculated by using slow motion maneuvering equation in the horizontal plane. The wind forces are calculated from the empirical formula of ABS and the mooring forces of ropes and fenders are modeled as linear spring.

The Action of Acetylcholine on the End-Plate Potential

  • Koh, Il-Sup
    • The Korean Journal of Physiology
    • /
    • v.9 no.2
    • /
    • pp.41-48
    • /
    • 1975
  • The failure of the action potential at the end-plate membrane to reach the sodium equilibrium potential is due to the stimulating action of acetylcholine on $Na^+-K^+$ pump. This action of acetylcholine causes an enormous increase in the $K^+$ transport rate. The quantitative amount of potassium ions in the inside of the end-plate membrane prevented the permeability of sodium ions during the depolarization phase of the action potential. It would favor the changes in the shape of action potential by acetylcholine which are always toward a fixed potential slightly below the zero line. The increased $Na^+-K^+$ pump activity by acetylcholine is responsible for the hypopolarization of membrane. This reduces the membrane resistance of the end-plate during transmitter activity.

  • PDF

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.

Implementation of a Condition Monitoring System for Mold Transformers in DC Substations (DC 변전소 몰드변압기 온라인 상태 감시 시스템 구현)

  • Park, Young;Jung, Ho-Sung;Park, Chul-Min;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1788-1794
    • /
    • 2011
  • The mold transformer is a complex and critical component of DC substations in Metro system. In this paper, a cost effective and intelligent condition monitoring system for mold transformers in DC substations was developed. This paper also provides an overview of the management program using PD (partial discharge) data on mold transformers. Prior to application of the proposed system to Metro DC substations, experiments were performed at the metro line substation located in Seoul and presented case studies for the use of the intelligent condition monitoring system for mold transformer in DC substations. The experiment results indicated that the developing system can be need in helping mange the risk of unexpected failure of mold type transformers.

Reliability Assessment Considering PLOC and Unified Evaluation via Analytic Network Process (PLOC를 고려한 배전계통의 신뢰도 계산 및 ANP에 의한 종합적 평가)

  • Lee, Buhm;Kim, Yong-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.59-67
    • /
    • 2000
  • This paper describes the unified reliability evaluation with partial loss of continuity for Inchon international airport distribution system which is complex and difficult system to implement. To evaluate reliability considering line limitation and voltage drop of the system, PLOC technique which is based on deterministic evaluation technique and failure mode & effective analysis method is employed. And reliability indices calculation method is used. Finally, to evaluate the system performance and to improve the reliability of the system, Analytic network process method is employed. As a result, calculating accurate reliability, finding weak points, and expansion scheduling of the system is possible.

  • PDF

A Policy on Efficient Load-Balancing Using Contents-Based Game Servers

  • Myung, Won-Shig
    • International Journal of Contents
    • /
    • v.3 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • This paper proposes a policy on efficient load balancing that can reduce the network game server load burdened by surging number of users. The study adopted a contents-based clustering technique. Recently, skyrocketing number of clients in on-line games causes overloads on specific game servers, and the consequent server-instability brings the worst situation: a server failure. To cope with this problem, one can install more high-powered servers or be equipped with back-up servers, which is often inefficient in terms of cost performance. To solve this problem, the present study examined the technology enhancing the performance and efficiency of game servers by reducing the loads of specific game servers. In doing this, this study used the clustering technology to compose game servers classified by their contents and carried out appropriate load balancing to numerous clients with load balancers in each region.

Development of the Protocol for the Power Management Agent System with IEEE 1344 (IEEE 1344를 이용한 Agent형 전력 관리 시스템 프로토콜 설계)

  • Lee, Jong-Eun;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.105-107
    • /
    • 2005
  • The Power system is one of the biggest and complicated non-linear systems. It is necessary to develop the power defense system to manage the power system efficiently and to prevent from the power failure, black out in nationwide, that is caused by a specific bus or power transmission line. In this paper, the power system developed here is called 'Power Management Agent System' in which a protocol to communicate for this system is developed. The protocol is designed based on the IEEE 1344 for synchronized system with GPS. Also we developed a simulation system to demonstrate how to implement the protocol.

  • PDF

Field Tests on the Lightning Shielding Failure of Overhead Distribution Line (가공배전선로의 직격뢰 차폐실패 실증)

  • Ryoo, Hee-Suk;Kim, Dae-Kyung;Nam, Kee-Young;Lee, Jae-Duck;Park, Sang-Man;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.650-652
    • /
    • 2005
  • 우리나라 가공배전선로는 가능한 한 직격뢰의 침입을 방지하기 위하여 차폐각이 $45^{\circ}$가 되도록 가공 지선을 설치하고 있으며, 이 경우에도 흡인공간이론에 따르면 수[kA] 정도의 뇌격은 차폐실패로 인하여 상도체에 직접 침입(직격)할 수 있으므로, 직격뢰에 의해 발생할 수 있는 뇌과전압의 실제 크기를 파악하는 것은 절연 설계나 절연협조에 있어 매우 중요하다. 본 논문에서는 차폐실패에 의해 가공배전선로의 상도체에 직격뢰가 침입한 경우에 발생하는 뇌과전압에 대하여, 실제의 선로와 동일한 구성과 규모의 실증선로를 이용하여 실증에 의해 고찰하였다.

  • PDF