• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.026 seconds

Analysis of Interrelationship between Undrained Static and Cyclic Shear Behavior for Nak-Dong River Sand (낙동강 모래의 비배수 정적 및 반복 전단거동 상호관계 분석)

  • Kim, Dae-Man;Kim, Byung-Tak
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.151-163
    • /
    • 2006
  • This paper presents the interrelationship between undrained static and cyclic shear behavior. Laboratory works were performed through the undralned static and cyclic triaxial test using Nak-Dong River sand. And static triaxial test involved the triaxial extension test for comparison with cyclic shear behavior Cyclic triaxial test was performed with a variety of combination conditions of initial static shear stress $(q_{st})$ and cyclic stress $(q_{cy})$. In this result, the stress path of cyclic shear behavior was correspondent with static shear behavior passing the critical stress ratio (CSR) line because of the development of flow deformation. After that, a failure occurred according to failure line (FL) of static shear behavior. The stress path of cyclic shear behavior showed essentially the same with static shear behavior, although it appears a little different in test method.

Ground Behavior and Reinforcing Methods of NATM Tunnel through Deep Weathered Zone (대심도 풍화대층에서 NATM 터널의 지반거동 및 보강방법)

  • Chun, Byung-Sik;Song, Seung-Hoon;An, Jung-Whan
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.87-95
    • /
    • 2007
  • This study analyzed ground settlement and ground stress depending on tunnel excavation and the ground reinforcing grouting methods for double line road tunnel through deep weathered zone. Diameter of double line road tunnel was approximately 12m and umbrella arch method and side wall reinforcing grouting were applied. The ring-cut split excavation method and CD-cut excavation method for excavation method were applied. Analyses of failure rate and vertical stress ratio show that the tunnel for which the height of the cover (H) was higher than four times the diameter, can be considered a deep tunnel. Comparisons of various excavation and ground reinforcement methods showed that CD-cut method results in lower surface and crown settlement, and lower failure rate than that obtained by Ring-cut split method. In addition, the side wall reinforcing grouting resulted in reduction of tunnel displacement and settlement.

Effect of internal stability on the failure properties of gravel-sand mixtures

  • Zhongsen Li;Hanene Souli;Jean-Marie Fleureau;Jean-Jacques Fry;Tariq Ouahbi;Said Taibi
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.395-403
    • /
    • 2023
  • The paper investigates the effect of two parameters - sand content (SC) and grain migration during shearing - on the mechanical properties of gravel-sand mixtures. Consolidated undrained (CU) triaxial tests were carried out on eight series of mixtures containing gravel (1<d<16 mm) and sand (0.1<d<1 mm). The prepared mixtures have sand contents of 0, 10, 15, 20, 40, 54, 94 and 100%, and a relative density of 60%. The transition sand content (TSC) is experimentally defined and marks the transition from gravel-driven to sand-driven behavior. For SC<TSC, the dry density of the mixture increases with SC. This induces an increase in undrained peak strength and dilative trend. The slope and position of the critical state line (CSL) are also deeply dependent on SC. At SC=TSC, the mixtures exhibit the largest dry density and yield the highest undrained peak strength and the largest dilative trend. During shearing, large internal migration of grains was observed at the TSC, causing heterogeneity in the sample. Analysis of the CSL deduced from the final points of the triaxial tests shows that, at the TSC, failure appears to correspond to the behavior of the coarsest fraction of the soil. This fraction is located in the upper part of the sample, where the sand particles had been eliminated by suffusion. On the other hand, in the more stable materials, the CSL is consistent with the bulk grain size distribution of the soil.

LINE-1 and Alu Methylation Patterns in Lymph Node Metastases of Head and Neck Cancers

  • Kitkumthorn, Nakarin;Keelawat, Somboon;Rattanatanyong, Prakasit;Mutirangura, Apiwat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4469-4475
    • /
    • 2012
  • Background: The potential use of hypomethylation of Long INterspersed Element 1 (LINE-1) and Alu elements (Alu) as a biomarker has been comprehensively assessed in several cancers, including head and neck squamous cell carcinoma (HNSCC). Failure to detect occult metastatic head and neck tumors on radical neck lymph node dissection can affect the therapeutic measures taken. Objective: The aim of this study was to investigate the LINE-1 and Alu methylation status and determine whether it can be applied for detection of occult metastatic tumors in HNSCC cases. Methods: We used the Combine Bisulfite Restriction Analysis (COBRA) technique to analyse LINE-1 and Alu methylation status. In addition to the methylation level, LINE-1 and Alu loci were classified based on the methylation statuses of two CpG dinucleotides in each allele as follows: hypermethylation ($^mC^mC$), hypomethylation ($^uC^uC$), and 2 forms of partial methylation ($^mC^uC$ and $^uC^mC$). Sixty-one lymph nodes were divided into 3 groups: 1) non-metastatic head and neck cancer (NM), 2) histologically negative for tumor cells of cases with metastatic head and neck cancer (LN), and 3) histologically positive for tumor cells (LP). Results: Alu methylation change was not significant. However, LINE-1 methylation of both LN and LP was altered, as demonstrated by the lower LINE-1 methylation levels (p<0.001), higher percentage of $^mC^uC$ (p<0.01), lower percentage of $^uC^mC$ (p<0.001) and higher percentage of $^uC^uC$ (p<0.001). Using receiver operating characteristic (ROC) curve analysis, $%^uC^mC$ and $%^mC^uC$ values revealed a high level of AUC at 0.806 and 0.716, respectively, in distinguishing LN from NM. Conclusion: The LINE-1 methylation changes in LN have the same pattern as that in LP. This epigenomic change may be due to the presence of occult metastatic tumor in LN cases.

Treatment Outcome of Locally Advanced Non-small Cell Lung Cancer Patients Who Received Concurrent Chemoradiotherapy with Weekly Paclitaxel (Paclitaxel 매주 투여 및 방사선치료 동시요법을 받은 국소진행성 비소세포폐암 환자들의 치료 결과)

  • Kim, Su-Zy;Shim, Byoung-Yong;Kim, Chi-Hong;Song, So-Hyang;Ahn, Meyung-Im;Cho, Deog-Gon;Cho, Kyu-Do;Yoo, Jin-Young;Kim, Hoon-Kyo;Kim, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.230-236
    • /
    • 2006
  • $\underline{Purpose}$: To analyze the response, toxicity, patterns of failure and survival rate of patients with locally advanced non-small cell lung cancer who were treated with concurrent chemoradiotherapy with weekly paclitaxel. $\underline{Materials\;and\;Methods}$: Twenty-three patients with locally advanced non-small cell lung cancer patients who received radical chemoradiotherapy from October 1999 to September 2004 were included in this retrospective study. Patients received total $55.4{\sim}64.8$ (median 64.8) Gy (daily 1.8 Gy per fraction, 5 days per weeks) over $7{\sim}8$ weeks. 50 or $60\;mg/m^2$ of paclitaxel was administered on day 1, 8, 15, 22, 29 and 36 of radiotherapy. Four weeks after the concurrent chemoradiotherapy, three cycles of consolidation chemotherapy consisted of paclitaxel $135\;mg/m^2$ and cisplatin $75\;mg/m^2$ was administered every 3 weeks. $\underline{Results}$: Of the 23 patients, 3 patients refused to receive the treatment during the concurrent chemoradiotherapy. One patient died of bacterial pneumonia during the concurrent chemoradiotherapy. Grade 2 radiation esophagitis was observed in 4 patients (17%). Sixteen patients received consolidation chemotherapy. During the consolidation chemotherapy, 8 patients (50%) experienced grade 3 or 4 neutropenia and one of those patients died of neutropenic sepsis. Overall response rate for 20 evaluable patients was 90% including 4 complete responses (20%) and 14 partial responses (70%). Among 18 responders, 9 had local failure, 3 had local and distant failure and 2 had distant failure only. Median progression-free survival time was 9.5 months and 2-year progression-free survival rate was 19%. Eleven patients received second-line or third-line chemotherapy after the treatment failure. The median overall survival time was 21 months. 2-year and 5-year survival rate were 43% and 33%, respectively. Age, performance status, tumor size were significant prognostic factors for progression-free survival. $\underline{Conclusion}$: Concurrent chemoradiotherapy with weekly paclitaxel revealed high response rate and low toxicity rate. But local failure occurred frequently after the remission and large tumor size was a poor prognostic factor. Further investigations are needed to improve the local control.

Dielectric passivation effects on the electromigration phenomena in Al-1%Si thin film interconnections (A1-1%Si 박막배선에서 엘렉트로마이그레이션 현상에 미치는 절연보호막 효과)

  • 김경수;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.27-30
    • /
    • 2001
  • Electromigration Phenomena in Al-1%Si thin film interconnections under DC and PDC conditions were investigated. Thin film interconnections with $SiO_2$ and PSG/$SiO_2$ dielectric passivation layer were formed by a standard photolithography process method and test line lengths were 100, 400, 800, 1200, and 1600 $\mu\textrm{m}$. The current density of $1.19\times10^7\textrm{A/cm}^2$ was stressed in Al-1%Si thin film interconnections under DC condition. The current density of $1.19\times10^7\textrm{A/cm}^2$ was also applied under PDC condition at the frequency of 1 Hz with the duty factor of 0.5. The electromigration resistance of PSG/SiO2 dielectric passivation test line was stronger than $SiO_2$ dielectric passivation test line. The lifetime under PDC was 2-4 times longer than DC condition. As the thin film interconnection line increased, the lifetime decreased and saturated over the critical length. Failure patterns by an electromigration were dominated by void-induced electrical open and hillock-induced electrical short.

  • PDF

Development of Bypass Unit for Ship Area Network Based on Legacy-line Communication (무배선 통신을 위한 선박 네트워크용 바이패스 장치 개발)

  • Jun, Ho-Ik;Kim, Hyun-Sik;Jung, Kyun Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.292-297
    • /
    • 2015
  • In this paper, we reported the bypass unit for ship area networks in order to detour the communication failure regions and poor communication links. The device was composed of three parts of circuits for power cut-off, protection, and coupling transformer. Since the coupling transformer exerts a dominant influence on the performance of the by-pass unit, we have tried to find the optimal magnetic core materials and its dimensions. The prototype was passed through the performance test of insertion loss, temperature, and vibration characteristics. The insertion loss was around -2 dB in the range of 90 kHz ~ 30 MHz and the average communication speed was 59.2 Mbps in the laboratory. A pilot communication test using the developed tool was conducted in the training ship of the Korea Maritime and Ocean University. As a results of experiment, we showed that the wired communication among the heterogeneous-links in the ship area networks are possible by the bypass unit and also a high speed communication services are available in ~ Mbps by using a power-line.

3DImmersion Type Virtual Environment System : Training Interruption-free Live-Line Workers (무정전 활선작업 피교육자를 위한 3차원 몰입형 가상환경 교육시스템의 개발)

  • 정영범;박창현;김기현;장길수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.22-30
    • /
    • 2004
  • As an information-oriented society comes, many people use PC and depend on database that network server has. However, the online data can be missed when a blackout happens and also a power failure effects on standard of judgment on Power Quality. Thus, it is reason of a trend using interruption-free live-line work when a trouble happens to power system. However, the 83% among the number of people who receive an electric shock experience when a laborer is doing interruption-free live-line works. In interruption-free method, the education and the training problem has been issued. However, we have a few instructors for that training. Furthermore, the trainees have short training period, just 4 weeks. In this paper, to develope the method that has no restriction of a time and place and reduce the wasteful materials, immersion type virtual reality(or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by doing same action in the real safe environment. Thus, it can be valuable to apply this training system to a dangerous work like as "Interruption-free live-line work exchanging COS(Cut-Out-Switch)". In this program, the user works with a instruction on the window and speaker and can't work other tasks until each part of the task completed. The workers using this system can use their hands and viewpoint movement as he is in a real environment but the trainee can't use all parts and senses of a real body with the current VR technology. Despite of this weak point, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has a high potentiality.

Optimal buffer allocation of the solenoid production line using simulation (시뮬레이션 모델 구축과 분석을 통한 솔레노이드 생산라인의 최적 버퍼 할당)

  • Kim, Young-Jin;Noh, Sang-Do;Mun, Joung-H.
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.4
    • /
    • pp.51-60
    • /
    • 2008
  • The purpose of this study is the use of simulation modelling to enhance productivity. In this paper, the optimal buffer allocation of small and medium size industries which produce solenoid valves for automobiles, is performed using simulations. The simulation model was developed under considerations of production layout, process & operation, process time, total work time, WIP, utilization, failure rate, and operation efficiency as inputs, and it was validated with careful comparisons between real behaviors and simulation outputs of the production line. Therefore, we can evaluate effects and changes in productivity when some strategies and/or crucial factors are changed. Although too large buffer could decrease productivity, the solenoid production line in this paper has been maintained large buffer. It is because reducing the size of buffer could result in the termination of the process. We determined the optimal number of buffers that could not cause any interrupt in productions using simulations. This simulation model considers diverse input variables which could influence productivity, and it is very useful not only for the production line of solenoid valves, but also for other production lines with various purposes, especially, small and medium size industries.

  • PDF

Development of a 3-D Immersion Type Training Simulator

  • Jung, Young-Beom;Park, Chang-Hyun;Jang, Gil-Soo
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.171-177
    • /
    • 2004
  • In the current age of the information oriented society in which we live, many people use PCs and are dependant on the databases provided by the network server. However, online data can be missed during the occurrence of a blackout and furthermore, power failure can greatly effect Power Quality. This has resulted in the trend of using interruption-free live-line work when trouble occurs in a power system. However, 83% of the population receives an electric shock experience when a laborer is performing interruption-free live-line work. In the interruption-free method, education and training problems have been pinpointed. However, there are few instructors to implement the necessary training. Furthermore, the trainees undergo only a short training period of just 4 weeks. In this paper, to develop a method with no restrictions on time and place and to ensure a reduction in the misuse of materials, immersion type virtual reality (or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by performing the equivalent action in a safe environment. Thus, it can be valuable to apply this training system to such dangerous work as 'Interruption-free live-line work exchanging COS (Cut-Out-Switch)'. In this program, the user carries out work according to instructions displayed through the window and speaker and cannot perform other tasks until each part of the task is completed in the proper sequence. The workers using this system can utilize their hands and viewpoint movement since they are in a real environment but the trainee cannot use all parts and senses of a real body with the current VR technology. Despite these weak points, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has high potentiality.