• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.032 seconds

Model Tests of Soil Nailing System under Surcharges (상재하중 하의 Soil Nailing System의 모형실험)

  • Yoo, Nam-Jae;Yoo, Kun-Sun;Kim, Jae-II
    • Journal of Industrial Technology
    • /
    • v.14
    • /
    • pp.77-87
    • /
    • 1994
  • This research is an experimental work of investigating the behavior of soil nailing system under surcharges whereas most of them were concentrated on evaluating its capacity under selfweight of excavated ground. Model tests in laboratory were performed to investigate the ultimate bearing capacity of soil nailing system under surcharges in forms of strip loading. Tests were carried out to find parameters controlling its capacity such as length of nail, vertical and horizontal spacings between nails, inclination of nail installation, and loading position of surcharges. Failure mechanism of forming failure line due to surcharge to soil nailing system was also observed by using dyed sand and monitoring its behavior. From results of these test, effects of parameters was analyzed qualitatively. Thus, this experimental results could provide meaningful data to analyze and design this system later.

  • PDF

A Study for the Prediction Method of Fault Symptoms on Distribution Feeders(I) (배전선로 고장징후 예지 시스템 개발에 관한 연구(I))

  • Shin, Jeong-Hoon;Kim, Tae-Won;Park, Seong-Taek
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1213-1216
    • /
    • 1998
  • This paper presents the result of a feasibility study for the prediction method of fault symptoms on 22.9kV distribution line. In this paper, real distribution data was collected and analyzed to isolate failure signatures or parameters which were distinct behaviors before and after failure incident. A new strategy of analysis-based (event-date concept) prediction algorithm for the distribution insulators and a developed model system were also discussed.

  • PDF

A Study on the Fault analysis of train control system by CAMS (CAMS에 의한 고속선 열차제어시스템 장애 분석에 관한 연구)

  • Kim, Yong-Kyu;Baek, Jong-Hyun;Ryu, Sang-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1436-1441
    • /
    • 2006
  • In this paper, Computer-aided Maintenance Equipments, which are being used in High Speed Line Train Control System, are applied to analyze failures in train control systems, resulting in long time delays of trains. It can be expected to extend and apply CAMS(Computer Aided Maintenance System) in the hereafter efficient operation and maintenance of high speed railway train control systems, by comparison between the analysis result of fundamental causes, from high speed railway train control system failure occurred during the operational process, and predictive result of failure causes, based on the recording data of CAMS when failures were occurred.

  • PDF

(A study failure-strength characteristics of soil layer contained Corestone) (핵석을 포함하는 토층의 파괴강도 특성연구)

  • 이수곤;금동헌
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.711-716
    • /
    • 2002
  • When judging the ground by core-logging, depth of coring might be stopped by coming into view of the moderately weathered rock and also considered as bedrock line. However, highly weathered rock may appear again, if coring more, because there are core-stones in the residual soil and highly weathered rock by the effect of hydraulic-thermal differentiation and does the irregular rock weathering or metamorphic rock region. Therefore, there are room for misunderstanding of diagnosing the moderately weathered rock. Even though the irregular ground where the corestones were come out will show clear geotechnical differences between the ground and the gradually weathered bedrock, nowadays, the construction sites do not take into account the characteristic of core-stone region. In conclusion, to study the failure-strength characteristics of soil layers containing core-stones, we made artificial core-stones and varied percentage of corestones, and measured cohesion and friction factors to adjust them to construction sites containing corestones such as slope, tunnel, and underground.

  • PDF

A Static Test of Concrete Barrier on Bridge Deck (교량 바닥판의 콘크리트 난간에 대한 정적 실험)

  • Kang, Jun-Wook;Lee, Jae-Hoon;Woo, Kwang-Sung;Ahn, Sang-Sub;Lee, Il-Gun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.33-36
    • /
    • 2004
  • The current Korea bridge design specifications have no provisions about concrete Barrier. And there are no test results of registence strength of the concrete barrier at the vehicle collision sites. This paper reports experimental results of concrete barrier on bridge deck conctructed by standard drawing of SB5 grade. Eight specimens were tested under static test. The specimens are divided by two groups (D-series and B-series). D-series is to show failure pattern of bridge deck. B-series is to show failure pattern of concrete Barrier. The test results compared with calculation results using Yield-Line theory of AASHTO LRFD Bridge Design Specifications.

  • PDF

Analysis of Insulation Condition in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.631-635
    • /
    • 2007
  • Diagnostic, surge and ac breakdown tests are widely used to evaluate the insulation condition of stator winding in traction motor. Diagnostic test included ac current, tan delta and maximum partial discharge. The result of diagnostic test indicates that five kinds of stator windings are good condition. Surge test was peformed to confirm the healthy of turn insulation in stator windings. This test is very easy to detect the turn insulation failure between normal and defect stator windings. After completing the diagnostic test, ac breakdown test has conducted gradually increasing ac voltage, until the stator winding punctured. No. 5 stator windings failed near rated voltage of 18.9 kV The breakdown voltage of No. 1 stator windings was 13.0 kV The ac breakdown voltage of normal winding is about 1.45 times higher than that of defect windings. The failure was located in a line-end coil at the exit from the core slot.

Earth Pressure Analysis of Tunnel Ceiling according to Tunnel Plastic Zone (터널 소성영역에 따른 터널 천단토압 해석)

  • Park, Shin-Young;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.753-764
    • /
    • 2020
  • In this study, the plastic zone and internal earth pressure of the tunnel were calculated using the following three methods: metal plasticity to analyze the deformation of metal during plastic processing, Terzaghi's earth pressure theory from the geotechnical perspective and modified Terzaghi's earth pressure theory, and slip line theory using Mohr-Coulomb yield conditions. All three methods are two-dimensional mathematical analysis models for analyzing the plane strain conditions of isotropic materials. Using the theory of metallurgical plastics, the plastic zone and the internal earth pressure of the ground were obtained by assuming that the internal pressure acts on the tunnel, so different results were derived that did not match the actual tunnel site, where only gravity was applied. An analysis of the plasticity zone and earth pressure via the slip-line method showed that a failure line is formed in a log-spiral, which was found to be similar to the real failure line by comparing the results of previous studies. The earth pressure was calculated using a theoretical method. Terzaghi's earth pressure was calculated to be larger than the earth pressure considering the dilatancy effect.

Proposed Landslide Warning System Based on Real-time Rainfall Data (급경사지 붕괴위험 판단을 위한 강우기반의 한계영역 설정 기법 연구)

  • Kim, Hong Gyun;Park, Sung Wook;Yeo, Kang Dong;Lee, Moon Se;Park, Hyuck Jin;Lee, Jung Hyun;Hong, Sung Jin
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.197-205
    • /
    • 2016
  • Rainfall-induced landslide disaster case histories are typically required to establish critical lines based on the decrease coefficient for judging the likelihood of slope collapse or failure; however, reliably setting critical lines is difficult because the number of nationwide disaster case histories is insufficient and not well distributed across the region. In this study, we propose a method for setting the critical area to judge the risk of slope collapse without disaster case history information. Past 10 years rainfall data based on decrease coefficient are plotted as points, and a reference line is established by connecting the outermost points. When realtime working rainfall cross the reference line, warning system is operating and this system can be utilized nationwide through setting of reference line for each AWS (Automatic Weather Station). Warnings were effectively predicted at 10 of the sites, and warnings could have been issued 30 min prior to the landslide movement at eight of the sites. These results indicate a reliability of about 67%. To more fully utilize this model, it is necessary to establish nationwide rainfall databases and conduct further studies to develop regional critical areas for landslide disaster prevention.

Comparing Effectiveness Rituximab (Mabthera®) to Other Second-line Biologics for Rheumatoid Arthritis Treatment in Patients Refractory to or Intolerant of First-line Anti-tumor Necrosis Factor Agent: An Observational Study

  • Park, Yong-Wook;Kim, Ki-Jo;Yang, Hyung-In;Yoon, Bo Young;Kim, Sang Hyon;Kim, Seong-Ho;Kim, Jinseok;Oh, Ji Seon;Kim, Wan-Uk;Lee, Yeon-Ah;Choe, Jung-Yoon;Park, Min-Chan;Lee, Sang-Heon
    • Journal of Rheumatic Diseases
    • /
    • v.24 no.4
    • /
    • pp.227-235
    • /
    • 2017
  • Objective. Failure of first-line anti-tumor necrosis factor (TNF) agents in in rheumatoid arthritis patients leads to decisions among second-line biologic agents. To better inform these decisions, the therapeutic effectiveness of rituximab is compared with other second-line biologic agents in this observational study. Methods. Between November 2011 and December 2014, study subjects were observed for 12 month periods. Patients with an inadequate response to initial anti-TNF agent received either rituximab or alternative anti-TNF agents (adalimumab/etanercept/infliximab) based on the preference of patients and physicians. The efficacy end point of this study was the change in 28-joint count Disease Activity Score (DAS28) at six and 12 months from baseline. Safety data were also collected. Results. Ninety patients were enrolled in the study. DAS28 at six months did not change significantly whether the patients were treated with rituximab or alternative anti-TNF agents in intention-to-treat analysis (n=34, $-1.63{\pm}0.30$ vs. n=31, $-2.05{\pm}0.34$) and standard population set analysis (n=31, $-1.51{\pm}0.29$ vs. n=24, $-2.21{\pm}0.34$). Similarly, the change in DAS28 at 12 months did not reach statistical significance ($-1.82{\pm}0.35$ in the rituximab vs. $-2.34{\pm}0.44$ in the alternative anti-TNF agents, p=0.2390). Furthermore, the incidences of adverse events were similar between two groups (23.5% for rituximab group vs. 25.8% for alternative anti-TNF agents group, p=0.7851). Conclusion. Despite the limitations of our study, switching to rituximab or alternative anti-TNF agents after failure of the initial TNF antagonist showed no significant therapeutic difference in DAS28 reduction.

Development of a Pulley-type Tensioning Device (도르래식 장력조정장치 개발)

  • Lee, Ki-Won;Cho, Yong-Hyeon;Park, Young
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.663-669
    • /
    • 2009
  • In the electrical railway, the increase of tensions in an overhead contact lines is essential to speed-up of train, because current collection quality largely depends on the ratio of a wave propagation speed to a train speed. For Kyungbu high-speed line, a pulley-type tensioning device is required to have a tension variation of maximum 3%. Therefore we developed a pulley-type tensioning device in order to meet tension variation requirement of the high-speed tensioning device. To verify the performance of the developed device, a performance test, overload test and failure test were carried out according to the factory test procedure of the Kyung-Bu High-speed line. Furthermore, we also performed reliability performance through not only a fatigue test in a factory, but also on-line verification test in Chungbuk line for over 1 year. These tests verified that the tensioning device had applicability to a main line.