• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.034 seconds

Optimal Routing of Distribution Network Considering Reliability Indices (신뢰도 지수를 고려한 배전계통의 최적 전력전송경로 결정)

  • 신동환;노병권;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1073-1080
    • /
    • 1999
  • Optimal routing of distribution networks can be attained by keeping the line power capacity limit to handle load requirements, acceptable voltage at customer loads, and the reliability indices such as SAIFI, SAIDI, CAIDI, and ASAI limits. This method is composed of optimal loss reduction and optimal reliability cost reduction. The former is solved relating to the conductor resistance of all alternative routes, and the latter is solved relating to the failure rate and duration of each alternative route. The routing considering optimal loss only and both optimal loss and optimal reliability cost are compared in this paper. The case studies with 10 and 24 bus distribution networks showed that reliability cost should be considered as well as loss reduction to achieve the optimal routing in the distribution networks.

  • PDF

Simulation of electromigration behavior on ULSI′s interconnect under pulsed DC stress : frequency, duty factor, temperature effect (Pulsed DC 조건에서 반도체 배선의 electromigration 시뮬레이션 : 주파수, duty factor, 온도효과)

  • 이동현;안진호;박영준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.40-42
    • /
    • 2002
  • Electromigration is atomic diffusion driven by a momentum transfer from conducting electrons. With every new generation of intergrated circuits, interconnect line widths have been reduced and current densities in the interconnect have become higher. This leads to an increase in the threat to interconnect reliability due to electromigration. In this paper, we simulated stress evolution with changing temperature, duty factor(ratio of on time and pulse time), frequency under pulsed DC condition. As a result, we predict MTF(median time to failure) and found that exponent n is affected by changing temperature, duty factor.

  • PDF

Inclined yield lines in flange outstands

  • Bambach, M.R.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.6
    • /
    • pp.623-642
    • /
    • 2008
  • While spatial plastic mechanism analysis has been widely and successfully applied to thinwalled steel structures to analyse the post-failure behaviour of sections and connections, there remains some contention in the literature as to the basic capacity of an inclined yield line. The simple inclined hinge commonly forms as part of the more complex spatial mechanism, which may involve a number of hinges perpendicular or inclined to the direction of thrust. In this paper some of the existing theories are compared with single inclined yield lines that form in flange outstands, by comparing the theories with plate tests of plates simply supported on three sides with the remaining (longitudinal) edge free. The existing mechanism theories do not account for different in-plane displacement gradients of the loaded edge, nor the slenderness of the plates, and produce conservative results. A modified theory is presented whereby uniform and non-uniform in-plane displacements of the loaded edge of the flange, and the slenderness of the flange, are accounted for. The modified theory is shown to compare well with the plate test data, and its application to flanges that are components of sections in compression and/or bending is presented.

An Accelerated Life Test of LED Lights for Aviation Taxiway (항공유도로등화용 LED 광원의 가속수명시험)

  • Min, Kyong-Chan;Yun, Yang-Gi;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.2
    • /
    • pp.127-140
    • /
    • 2011
  • This paper presents an accelerated life test of aviation taxiway lights installed in the airport to help safe navigation of airplanes at night or in bad weather. Recently halogen lamps of taxiway lights are replaced by LED ones and their reliability needs yet to be verified. Thus, effective test conditions are designed reflecting the failure modes and mechanisms from the previous studies on LED, which include the accelerated degradation process. The test is performed under the temperature $70^{\circ}C$ and $90^{\circ}C$ for two types of LED lights, taxiway center line lights(TCLL) and taxiway edge lights (TEDL). The failure time data were analyzed using lognormal distribution and Arrhenius model to find the life-stress relationship, acceleration factor and life characteristics under the normal condition temperature $30^{\circ}C$.

Assessment of Internal Leak on RCS Pressure Boundary Valves (원자로냉각재계통 압력경계밸브 내부누설 평가)

  • Park, Jun-Hyun;Moonn, Ho-Rim;Jeong, Ill-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.322-327
    • /
    • 2001
  • The internal leaks of RCS pressure boundary valves may cause thermal fatigue crack because of the TASCS in RCS branch line. After experienced unisolable piping failures in several PWR plants, many studies have peformed to understand these phenomena and various methods were applied to ensure the structural integrity of piping. In this paper, the cause of unisolable piping failures and the alternatives to prevent recurrence of failure were reviewed. Also, the severity of piping failure including susceptibility of valve leaks was evaluated for the Westinghouse 2-loop plant. The length of turbulent penetration on RHR inlet piping was measured and, thermal fluid analysis and fatigue analysis was performed for this piping. As a means of ensuring the structural integrity, temperature monitoring and specialized UT and other alternatives were compared for the further application.

  • PDF

A Study on the Reliability Analysis for a Linear Type Pneumatic Actuator with Cross Roller Guide (리니어 타입 크로스 롤러 가이드 공압 액추에이터의 신뢰성 평가에 관한 연구)

  • Shin Bong-Cheol;Cho Myeong-Woo;Kang Sung-Min;Lee Soo-Jin;Choi Jin-Hwa
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.184-189
    • /
    • 2006
  • This research presents the performance analysis of the linear type pneumatic actuators that are used in semi-conductor assembly line to transfer some product with high accuracy. To increase positioning and repetitive accuracies, a cross roller guide is implemented inside the pneumatic actuator. The finite element method is used to verify the force against working moments, and reliability analysis is performed to classify the breakdown cases. Also, reliability, failure rate, probability density function, and $B_{10}$ to life are estimated under the boundary of thrust or air leakage conditions. In this study, the failure probabilistic function of the pneumatic actuators is analyzed using Weibull distribution.

Operation characteristics of a fault current limiter by high speed interrupter and a superconducting element

  • Im, I.G.;Jung, I.S.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.3
    • /
    • pp.10-14
    • /
    • 2014
  • Due to continuous increase of electric power consumption, couple of resolutions for improving accuracy in power system like line separation are being studied. The increase of the power demand can cause problems such as supply difficulties of the electricity and broadband outages, failure, etc. When a fault occurs in the power system, a fault current also increases. Fault current creates problems like reduction of lifespan and failure on the power system. In order to resolve these problems, the reduction of initial fault current using the characteristics of superconducting element was applied to fault current limiter. We applied the system to high speed fault current limiter. We found that the superconducting element effectively reduced initial fault current and the fault current was limited by changing operation of high speed interrupter.

The Cause of CCPU's failure and Improved Configuration Method in Combined Transmission Lines (실 계통의 혼합송전선로에서 CCPU파괴 원인과 그 대책)

  • Ha, C.W.;Kim, J.N.;Lee, S.K.;Heo, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.210-212
    • /
    • 2001
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-tine which is connected with overhead line and underground cable. This paper investigates the failure of CCPU(Cable covering Protection Unit) and presents improved configuration method of CCPU in underground cable system EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as overhead lines, underground cables, CCPUs and towers in presented.

  • PDF

The Calculation of Unbalanced Voltage on the tertiary bus of a single phase auto transformer in case of Parallel Operation with Different Manufacturer (제작소가 상이한 단상 주변압기 병행 운전시 불평형전압의 검토)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Joe, S.H.;Hur, Y.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.458-460
    • /
    • 2001
  • This paper described the unbalanced voltage on the tertiary bus of a single Phase auto transformer in the case of parallel operation with different manufacturer at each Phase. The unbalanced capacitances between primary to secondary winding, secondary to tertiary winding and primary to tertiary winding makes unbalanced bus voltage in the tertiary bus side. The unbalanced voltage let the surge arrester to operate in the power frequency range, and it causes the arrester to burn out. The failure of the arrester at one phase makes line to ground fault, which lead to the surge arrester failure of the other two phase on the tertiary bus.

  • PDF

Failure Analysis of Train Control System for Hign Speed Line by CAMS (CAMS에 의한 고속선 열차제어시스템의 장애 분석)

  • Kim, Yong-Kyu;Baek, Jong-Hyun;Kim, Jong-Ki;Shin, Duck-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.973-974
    • /
    • 2006
  • In this paper, Computer-aided Maintenance Equipments, which are being used in maintenance, are applied to analyze failures in train control systems, resulting in long time delays of trains. It can be expected to extend and apply CAMS (Computer Aided Maintenance System) in the hereafter efficient operation and maintenance of high-speed railway train control systems, by comparison between the analysis result of fundamental causes, from high-speed railway train control system failures occurred during the operational process, and predictive result of failure causes, based on the recording data of CAMS when failures were occurred.

  • PDF