• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.022 seconds

Ultimate Strength of branch-rotated T-joints in Cold-formed Square Hollow Sections - Chord flange failure mode - (지관이 회전된 냉간성형 각형강관 T형 접합부의 최대내력(I) - 주관 플랜지 파괴모드 -)

  • Bae, Kyu Woong;Park, Keum Sung;Kang, Chang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.657-664
    • /
    • 2002
  • This paper described the ultimate strength and deformation limit of the new uniplanar T-joints in cold-formed square hollow sections. In the configuration of the new T-joint, only a branch member is orientated to a chord member at 45 degrees in the plane of the truss. This study focused on the branch-rotated T-joints that were governed by chord flange failure in previous studies. Test results of the T-joint in cold-formed square hollow sections revealed a deformation limit of 3%B for $16.7{\leq}2{\gamma}(=B/T){\leq}33.3$ and $0.27{\leq}{\beta}(=b1/B){\leq}0.6$. The existing strength formulae for traditional T-joint were determined and a new yield-line model for the branch-rotated T-joint proposed. Finally, the strength formula on the yield-line analysis was compared with test results and the application range of the proposed formula recommended.

Failure Analysis on Localized Corrosion of Heat Transport Pipe in District Heating System (지역난방 열수송관 국부 부식 파손 분석)

  • Kim, You Sub;Chae, Hobyung;Kim, Woo Cheol;Jeong, Joon Cheol;Kim, Heesan;Kim, Jung-Gu;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.122-130
    • /
    • 2020
  • In this study, a corrosion failure analysis of a heat transport pipe was conducted, as the result of a pinhole leak. Interestingly, the corrosion damage occurred externally in the pipeline, resulting in severe thickness reduction near the seam line. Also, while a stable magnetite protective film formed on the inner surface, the manganese oxide formation occurred only on the outer surface. The interior and exterior of the pipe were composed of ferrite and pearlite. The large manganese sulfide and alumina inclusions were found near the seam line. In addition, the manganese sulfide inclusions resulted in grooving corrosion, which progressed in the seam line leading to the reduction in the thickness, followed by the exposure of the alumina in the matrix to the outer surface. To note, the corrosion was accelerated by pits generated from the boundaries separating the inclusions from the matrix, which resulted in pinhole leaks and water loss.

Communication Methodology Between Digital FRTUs Based on Wi-Fi Communication for the Smart Grid of Distribution System Area (스마트 그리드 배전 시스템을 위한 와이파이 통신에 기반한 디지털 FRTU간 통신 방법론 기초연구)

  • Woo-Kyung, Jin;Ji-Hyeon, Youn;Min-Seok, Choi;Jae-Hyun, Lee;Birek, Ohgan;Yun-Seok, Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1113-1120
    • /
    • 2022
  • In this paper, a communication methodology for the digital FRTU(: Feeder Remote Terminal Unit) required by the smart grid distribution system was studied. The digital FRTU consists of a fault handling unit and a communication unit. The fault handling unit transmits fault information to the communication unit in case of a failure, and the communication unit is designed to autonomously determine the fault section through two-way communication between surrounding digital FRTUs. For performance verification, a performance verification system consisting of 3 line sections based on 3 digital FRTUs was constructed to enable fault simulation for various failure scenarios. Various fault cases including one phase ground fault, line-to-line short-circuit fault, and three-phase short-circuit fault were experimentally simulated on the established performance verification system, and the validity of the developed methodology was confirmed by proving the accurate fault section inference results for each fault simulation case.

Research on Backup Protective Coordination for Distribution Network (네트워크 배전계통용 백업 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Kim, JuYong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.15-19
    • /
    • 2022
  • The radial distribution systems (RDS) commonly used around the world has the following disadvantages. First, when the DL is operated on a radial system, the line utilization rate is usually kept low. Second, if a fault occurs in the radial DL, a power outage of 3 to 5 minutes is occurring depending on the operator's proficiency and fault situation until the fault section is separated and the normal section is replaced. To solve this problem, Various methods have been proposed at domestic and foreign to solve this problem, and in Korea, research is underway on the advanced system of operating multiple linked DL always. A system that is electrically linked always, and that is built to enable high-speed communication during the protection coordination is named networked distribution system (NDS). Because the load shares the DL, the line utilization rate can be improved, and even if the line faults, the normal section does not need to be cut off, so the normal section does not experience a power outage. However, since it is impossible to predict in which direction the fault current will flow when a failure occurs in the NDS, a communication-based protection coordination is used, but there is no backup protection coordination method in case of communication failure. Therefore, in this paper, we propose a protective cooperation method to apply as a backup method when communication fails in NDS. The new method is to change TCC by location of CB using voltage drop in case of fault.

A Case of Metastatic Pancreatic Cancer Treated with FOLFIRINOX as Second-Line Chemotherapy after Gemcitabine Failure (FOLFIRINOX 병합요법을 통한 이차 항암화학요법으로 완전 관해를 획득한 진행성 췌장암 증례)

  • Jae Min Lee;Kwang Hyun Chung;Jin Myung Park;Sang Hyub Lee;Ji Kon Ryu;Yong-Tae Kim
    • Journal of Digestive Cancer Research
    • /
    • v.2 no.1
    • /
    • pp.28-31
    • /
    • 2014
  • Pancreatic cancer is a highly aggressive cancer with poor prognosis. Although, gemcitabine is the current standard regimen as first-line chemotherapy for advanced pancreatic cancer, effective regimens of second-line chemotherapy after gemcitabine failure have not been established yet. We report a case of gemcitabine refractory pancreatic cancer treated with second-line chemotherapy with FOLFIRINOX regimen. A 57-year-old-woman visited our hospital for pancreatic body mass detected by computed tomography (CT). The patient underwent distal pancreatectomy and splenectomy and the pathologic results after surgery demonstrated adenocarcinoma. Follow-up was performed after surgery and CT and positron emission tomography (PET) 4 months after surgery revealed multiple hepatic metastases. The patient underwent first-line chemotherapy with gemcitabine and erlotinib for recurred pancreatic cancer. However, CT after 7 cycles of the chemotherapy showed the progression of multiple hepatic metastases and switch to second-line chemotherapy with FOLFIRINOX was initiated. CT after 16 cycles of the FOLFIRINOX showed the complete remission of multiple hepatic metastases. The patient was admitted for infective endocarditis with septic pneumonia 17 months after the initiation of FOLFIRINOX. However, the patients died from the progression of septic embolism and acute respiratory distress syndrome.

  • PDF

Improving the Accuracy of the Mohr Failure Envelope Approximating the Generalized Hoek-Brown Failure Criterion (일반화된 Hoek-Brown 파괴기준식의 근사 Mohr 파괴포락선 정확도 개선)

  • Youn-Kyou Lee
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.355-373
    • /
    • 2024
  • The Generalized Hoek-Brown (GHB) criterion is a nonlinear failure criterion specialized for rock engineering applications and has recently seen increased usage. However, the GHB criterion expresses the relationship between minimum and maximum principal stresses at failure, and when GSI≠100, it has disadvantage of being difficult to express as an explicit relationship between the normal and shear stresses acting on the failure plane, i.e., as a Mohr failure envelope. This disadvantage makes it challenging to apply the GHB criterion in numerical analysis techniques such as limit equilibrium analysis, upper-bound limit analysis, and the critical plane approach. Consequently, recent studies have attempted to express the GHB Mohr failure envelope as an approximate analytical formula, and there is still a need for continued interest in related research. This study presents improved formulations for the approximate GHB Mohr failure envelope, offering higher accuracy in predicting shear strength compared to existing formulas. The improved formulation process employs a method to enhance the approximation accuracy of the tangential friction angle and utilizes the tangent line equation of the nonlinear GHB failure envelope to improve the accuracy of shear strength approximation. In the latter part of this paper, the advantages and limitations of the proposed approximate GHB failure envelopes in terms of shear strength prediction accuracy and calculation time are discussed.

Application limit of Yield Line Analysis on Welded T-joints in Cold-Formed SHS Sections (냉간성형 각형강관 T형 접합부의 항복선해석 전용한계)

  • Kang, Chang Hoon;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.315-324
    • /
    • 2004
  • This study performs a yield line analysis of welded T-joints in cold-formed Square Hollow Sections (SHS) with the branch in axial compression. The existing yield line models proposed by Koto, Packer, Zhao, and CIDECT and the proposed yield line model of the previous study are compared, using the existing test results of welded T-joints in cold-formed SHS. The yield line model suggested in the previous paper, which is based on the simplified yield line analysis, is reviewed to evaluate its application limit on cold-formed SHS T-joints. In the proposed model, the round corner of the cold-formed SHS section and weld size are taken into account. Finally, the validity range of yield line analysis is determined by observing the actual failure modes and comparing the test value with the analysis value, set as ${\beta}^{\prime}{\leq}0.8$ where ${\beta}^{\prime}=0.8$, ${\beta}^{\prime}=b_1^{\prime}/b_0^{\prime}$, $b_1{^{\prime}}=b_1+t_0$ and $b_0{^{\prime}}=b_0-t_0$.

Analysis of Different 500kV HVAC Transmission Lines Lightning Shielding

  • Nayel, Mohamed
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.4
    • /
    • pp.49-57
    • /
    • 2013
  • The lightning shielding of different 500 kV HVAC-TL high voltage AC transmission lines was analyzed. The studied transmission lines were horizontal flat single circuit and double circuit transmission lines. The lightning attractive areas were drawn around power conductors and shielding wires. To draw the attractive areas of the high voltage transmission lines, transmission line power conductors, shielding wires and lightning leader were modeled. Different parameters were considered such as lightningslope, ground slope and wind on lightning attractive areas. From the calculated results, the power conductors voltages affected on attractive areas around power conductors and shielding wires. For negative lightning leader, the attractive area around the transmission line power conductor increased around power conductors stressed by positives voltage and decreased around power conductors stressed by negative voltage. In spite of this, the attractivearea of the transmission line shielding wire increasedaround the shielding wire above the power conductor stressed by the positive voltage and decreased around the shielding wire above the power conductor stressed by negative voltage. The attractive areas around power conductors and shielding wires were affected by the surrounding conditions, such as lightning leader slope, ground slope. The AC voltage of the transmission lines made the shielding areas changing with time.

The Study for Optimal Layout of the Eleutherococcus Senticosus Sap Production Line Analyzed by Simulation Model (시뮬레이션 모델 구축과 분석을 통한 가시오가피 액즙 가공 라인의 최적 배치에 관한 연구)

  • Kim, Young-Jin;Park, Hyun-Joon;Mun, Joung-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.461-466
    • /
    • 2011
  • The purpose of this study is basically for the use of simulations to enhance productivity. In this paper, the optimal number of allocation in a small and medium industry which produces eleutherococcus senticosus sap, is performed using simulations. The simulation model was developed under considerations of production layout, process & operation, process time, total work time, work in process (WIP), utilization, failure rate, and operation efficient as inputs, and was validated with careful comparisons between real behaviors and outputs of the production line. Therefore, we can evaluate effects and changes in productivity when some strategies and/or crucial factors are changed. Although too many workers and machines could decrease productivity, the eleutherococcus senticosus sap production line in this paper has been maintained many machines. To solve this problem, we determined the optimal number of workers and machines that could not cause any interrupt in productions using simulations. This simulation model considers diverse input variables which could influence productivity, and it is very useful not only for the production line of Eleutherococcus Senticosus Sap, but also for other production lines with various purposes, especially, in the small and medium industries.

Joule Heating Effects and Initial Resistance in Electromigration Test (EM시험에서의 Joule Heating 영향 및 초기저항값)

  • Ju, Cheol-Won;Gang, Hyeong-Gon;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.436-441
    • /
    • 1999
  • Joule heating effect in EM(Electromigration) test were performed on a bend test structure. EM test is done under high current densities(1.0-2.5MA/cm2), which leads to joule heating. Since joule heating is added to the controlled oven(stress) temperature, themetal line temperature is higher than the stress temperature. The increase in the stress temperature due to joule heating is important because EM phenomena and metal line failure are related to the stress temperature. In this paper, metal line was stressed with a current density of 1.0 MA/$cm^2$, 1.5MA/$cm^2$, 2.0MA/$cm^2$, 2.5MA/$cm^2$, for 1200 sec and temperature increase due to joule heating was less than $10^{\circ}C$. Also it took 30 minutes for the metal line to equalized with oven temperature. Recommendations are given for the EM test to determine the initial resistance of EM test structure under stress temperature and current density.

  • PDF