• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.034 seconds

Application of Slip-line Method to the Evaluation of Plastic Zone around a Circular Tunnel (원형터널 주변의 소성영역 평가를 위한 slip-line 해석법 활용)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.32 no.5
    • /
    • pp.312-326
    • /
    • 2022
  • The generalized Hoek-Brown (GHB) criterion, which is recognized as one of the standard failure conditions for rock mass, is specialized for rock engineering applications and covers a wide range of rock mass conditions. Accordingly, many research efforts have been devoted to the incorporation of this criterion into the stability analysis of rock structures. In this study, the slip-line analysis method, which is a kind of elastoplastic analysis method, is combined with the GHB failure criterion to derive analytical equations that can easily calculate the plastic radius and stress distribution in the vicinity of the circular tunnel. In the process of derivation of related formulas, it is assumed that the behavior of rock mass after failure is perfectly plastic and the in-situ stress condition is hydrostatic. In the formulation, it is revealed that the plastic radius can be calculated analytically using the two respective tangential friction angles corresponding to the stress conditions at tunnel wall and elastic-plastic boundary. It is also shown that the plastic radius and stress distribution calculated using the derived analytical equations coincide with the results of Lee & Pietruszczak's numerical method published in 2008. In the latter part of this paper, the influence of the quality of the rock mass on the size of the plastic zone, the stress distribution, and the change of the tangential friction angle was investigated using the derived analytical equations.

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

An embedded crack model for failure analysis of concrete solids

  • Dujc, Jaka;Brank, Bostjan;Ibrahimbegovic, Adnan;Brancherie, Delphine
    • Computers and Concrete
    • /
    • v.7 no.4
    • /
    • pp.331-346
    • /
    • 2010
  • We present a quadrilateral finite element with an embedded crack that can be used to model tensile fracture in two-dimensional concrete solids and the crack growth. The element has kinematics that can represent linear jumps in both normal and tangential displacements along the crack line. The cohesive law in the crack is based on rigid-plasticity with softening. The required material data for the concrete failure analysis are the constants of isotropic elasticity and the mode I softening curve. The results of two well known tests are presented in order to illustrate very satisfying performance of the presented approach to simulate failure of concrete solids.

Failure Mode Analysis of Mo-tip EFA Cold-Cathode in CRT Spot-knocking Process (CRT의 Spot-knocking 공정에 있어서 몰리브텐 팁 전계 방출 소자 냉응극의 고장 형태 분석)

  • Ju, Byeong-Kwon;Kim, Hoon;Park, Jong-Won;Kim, Nam-Soo;Kim, Dong-Ho;Lee, Yun-Hi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.414-418
    • /
    • 2001
  • Failure modes of Mo-tip FEA were investigated in detail as a preliminary study for the application of Mo-tip FEA to the CRT electron-gun as a cold cathode. It was identified that the destruction of Mo-tip FEA was originated from reflowing of arc-current during the spot-knocking process followed by secondary arc between gate electrode and cathode substrate. In order to prevent Mo-tip FEA from destruction due to arc-current, two kinds of methods were suggested, that is one is to provide the by-pass of the reflow current and the other is to install a current limiter in the path of gate connection line.

  • PDF

A Study on Auto synchronization failure of a Generator (수력발전기 자동동기투입 실패에 관한 고찰)

  • Jeon, Kyu-Nam;Chang, Moon-Soung;Lee, Jae-Hoon;Jeong, Jae-Won;Ahn, Ju-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.268-269
    • /
    • 2006
  • Auto-synchonizer is important device to match the voltage, frequency, phase of the generating system to those factors of the transmission line, when the synchronous generator is operated. There were few or no incidents by Synchronization failure at Hapcheon hydraulic power plant, since it was built in 1989. but incidents by Synchronization failure have often happend lately. From now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem by comparing with the set point of each device of synchronizing system.

  • PDF

A Study on the Failure Behavior of Carbon Fiber Sheet Reinforced Mortar Using Acoustic Emission Technique (AE를 이용한 탄소섬유시트 강화 모르타르의 파괴거동에 관한 연구)

  • 이진경;이준현;장일영
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.67-75
    • /
    • 2000
  • It was well recognized that the damages associated mainly with the aging of civil infrastructures were one of very serious problems for assurance of safety and reliability. Recently carbon fiber sheet(CFS) has been widely used for reinforcement and rehabilitation of damaged concrete beam. However, the fundamental mechanism of load transfer and its load-resistant for carbon fiber sheet reinforced concrete are not fully understood. In this study, three point bending test has been carried out to understand the damage progress and the micro-failure mechanism of CFS reinforced mortars. For this purpose, four different types of specimens are used, that is, mortar, steel bar reinforced mortar, CFS reinforced mortar, and steel bar and CFS reinforced morter. Acoustic Emission(AE) technique was used to evaluate the characteristics of damage progress and the failure mechanism of specimens. in addition, two-dimensional AE source location was also performed to monitor crack initiation and propagation processes for these specimens.

Study on defect of ERW weldment of carbon steel pipes (탄소강관의 ERW 용접부 손상에 관한 연구)

  • Lee, Bo-Young;Lee, Jea-Yun;Lee, Seong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.666-669
    • /
    • 2003
  • Electrical resistance welded steel pipes showed leakage failure within 5 years usage. Microstructural analysis and hardness test were carried out, whose results gave no evidences about the reason of failure. For the analysis, 3 kinds of ERW pipes with different heat inputs were produced. Microstructural differences according to the different heat inputs were detected. Differences of the amount of inclusion in the weld line were observed. It is concluded that the difference of heat input during ERW pipe production caused the microstructural changes which resulted in the leakage failure.

  • PDF

A Predication of Failure in the Stamping Line by Using the Plane Strain Stretch Test (평면 변형 장출 시헙법(PSST)을 이용한 프레스라인에서의 성형 불량 예측)

  • 한수식;박기철;진조관
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.15-18
    • /
    • 1997
  • The plane strain stretch test (PSST) developed by POSCO as an activity of customer service was applied to the establishment of the formability criteria and the prediction of failure during the stamping processes. The PSST was applied to the actual parts such as oil pan and shock mount and the criteria of PSST value for each forming parts were established. These value can provide the possibility of prediction of failure before the stamping process. These results show that the PSST can precisely predict the stamping formability of steel sheets.

  • PDF

Seoulmetro Power Cable's Obstacle situation analysis (서울메트로 전력케이블 장애현황 분석)

  • Wi, Sam-Bok;Jung, No-Geon;Kim, Jae-Moon;Kim, Yang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1611-1612
    • /
    • 2015
  • This research paper is to analyze the specific situation for the 157 failure cases of Seoul Metro power cable since 1990 and to consider the countermeasures. This is, also, to prevent accidents by analyzing the current state of each Line, the failure of causes, railroad tracks, installation year, opening year, and monthly failure conditions and by presenting the countermeasures. In addition, this research is to discuss the present installation situation of Seoul Metro power cable, the types of power cable, symptoms, causes and the countermeasures.

  • PDF

Lifetime Estimation of Amplifier IC due to Electromigration failure (Electromigration 고장에 의한 Amplifier IC의 수명 예측)

  • Lee, Ho-Young;Chang, Mi-Soon;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1265-1270
    • /
    • 2008
  • Electromigration is a one of a critical failure mechanism in microelectronic devices. Minimizing the thin film interconnections in microelectronic devices make high current densities at electrrical line. Under high current densities, an electromigration becomes critical problems in a microelectronic device. This phenomena under DC conditions was investigated with high temperature. The current density of 1.5MA/cm2 was stressed in interconnections under DC condition, and temperature condition $150^{\circ}C,\;175^{\circ}C,\;200^{\circ}C$. By increasing of thin film interconections, microelectronic devices durability is decreased and it gets more restriction by temperature. Electromigration makes electronic open by void induced, and hillock induced makes electronic short state.

  • PDF