• Title/Summary/Keyword: factors affecting concrete strength

Search Result 57, Processing Time 0.023 seconds

Correction of Various Testing Factors Affecting Measured Compressive Strength of Concrete Core (콘크리트 코어 압축강도의 각종 영향인자 보정)

  • Park, Seok-kyun;Choi, Ook;Oh, Kwang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.973-978
    • /
    • 2002
  • This study was performed to verify the effect of various testing conditions affecting measured compressive strength of concrete core and to compute the correction coefficients for it. Conditions of specimens affecting test results include size(diameter), height-diameter ratio, humidity of specimen, amount and arrangement of bar, core direction from structure and method of end preparation. In testing core strength of concrete, special cares should be taken on various testing conditions whose effects have been latent in conventional concrete.

  • PDF

Experimental Study to Investigate the Factors Affecting Durability of Spalled Cement Concrete Pavements (스폴링이 발생한 콘크리트 포장의 내구성 영향인자 조사를 위한 실험적 연구)

  • Yoo, Tae Seok;Ryu, SungWoo;Kim, Jin Cheol
    • International Journal of Highway Engineering
    • /
    • v.20 no.2
    • /
    • pp.27-34
    • /
    • 2018
  • PURPOSES : It is necessary to prevent premature failure of concrete pavements caused by durability problems. The purpose of this study was to find factors affecting the durability of concrete pavements, and suggest improvement methods for existing concrete mix design. METHODS : Factors influencing durability were derived from laboratory test data for common field failure conditions and main properties of concrete cores taken from the field. The improvement of concrete properties was investigated by evaluating the performance of existing and proposed mix proportion designs and curing methods. RESULTS : The compressive strength and the absorbing performance of the low Blaine cement and the high-strength mixture were better than those of the Type I cement. Wet curing showed better compressive strength, elastic modulus, coefficient of thermal expansion, and absorption performance than air curing or compound curing. As a result of comparing concrete cores collected in the field, the sections with good durability showed good performance in terms of resistance to chloride ion penetration, absorption, and initial absorption rate. CONCLUSIONS : The absorption performance was considered as a possible foactor affecting durability of cement concrete pavements as a result of field core tests. In order to improve the durability of the pavement concrete, it is necessary to improve the existing mixtures and curing methods.

Comparison on the Failure Mechanism of Punching Shear in the Reinforced Concrete (철근 콘크리트의 뚫림전단 파괴메카니즘에 과한 비교)

  • 이주나;연규원;이호준;박찬수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.533-538
    • /
    • 2000
  • In R.C. flat slab system, a brittle punching failure is a very fatal problem. But there is no generally well-defined answer to the problem and there are wide differences in current practical design codes. therefore, in this study, the factors affecting to punching failure mechanism have been studied to find out the punching shear behavior in R.C. flat slabs by comparing other investigations and practical design codes. Therefore, In this study, the factors affecting to punching failure mechanism have been studied to find out the punching shear behavior in R.C. flat slabs by comparing other investigations and practical design codes. The conclusions in this study are summarized as follows; 1) The factors affecting to punching shear are concrete strength ($f_\alpha$), ratio of column side length to slab depth (c/d), ratio of distance from column center to radial contraflexure (l/d), yield strength of steel ($f_y$), flexural reinforcement ratio ($\rho$) and size effects. 2) It is shown that th use of $\surd{f_{ck}}$in applying($f_\alpha$ to punching shear strength estimation may be more sensitive in high concrete strength. 3) The effects of l/d, ($f_y$, size are no clear in the punching failure mechanism, so in the future, it should be investigated with the effects of various composed load.

  • PDF

An Experimental Study on the Influence of Bonding Material Content Affecting on the Engineering Properties of High Strength Flowing Concrete (Part II) properties of hardened concrete (고강도유동화 콘크리트의 공학적특성에 미치는 단위결합재량의 영향에 관한 실험적 연구 (제 2보 경화콘크리트의 공학적 특성))

  • 김진만;이상수;최진성;박정일;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.35-38
    • /
    • 1993
  • Although bonding material content of the high strength flowing concrete is very important in engineering properties, in rich mix concrete increasing the bonding material content may not follow more good properties. This study is to investigate the influence of the bonding material content affecting on the engineering properties of high strength flowing concrete, and this paper is to analyze the properties of hardened concrete. The results reveal that the strength of concrete having loss bonding material content is higher than that of concrete having more bonding material content, and that in proportion to increasing of concrete strength brittleness factors decrease, and that the static modulus of elasticity in this study is less than that in specification.

  • PDF

Potential of adaptive neuro fuzzy inference system for evaluating the factors affecting steel-concrete composite beam's shear strength

  • Safa, M.;Shariati, M.;Ibrahim, Z.;Toghroli, A.;Baharom, Shahrizan Bin;Nor, Norazman M.;Petkovic, Dalibor
    • Steel and Composite Structures
    • /
    • v.21 no.3
    • /
    • pp.679-688
    • /
    • 2016
  • Structural design of a composite beam is influenced by two main factors, strength and ductility. For the design to be effective for a composite beam, say an RC slab and a steel I beam, the shear strength of the composite beam and ductility have to carefully estimate with the help of displacements between the two members. In this investigation the shear strengths of steel-concrete composite beams was analyzed based on the respective variable parameters. The methodology used by ANFIS (Adaptive Neuro Fuzzy Inference System) has been adopted for this purpose. The detection of the predominant factors affecting the shear strength steel-concrete composite beam was achieved by use of ANFIS process for variable selection. The results show that concrete compression strength has the highest influence on the shear strength capacity of composite beam.

Factors affecting the properties of recycled concrete by using neural networks

  • Duan, Zhen-Hua;Poon, Chi-Sun
    • Computers and Concrete
    • /
    • v.14 no.5
    • /
    • pp.547-561
    • /
    • 2014
  • Artificial neural networks (ANN) has been proven to be able to predict the compressive strength and elastic modulus of recycled aggregate concrete (RAC) made with recycled aggregates (RAs) from different sources. However, ANN is itself like a black box and the output from the model cannot generate an exact mathematical model that can be used for detailed analysis. So in this study, sensitivity analysis is conducted to further examine the influence of each selected factor on the output value of the models. This is not only conducive to the determination and selection of the more important factors affecting the results, but also can provide guidance for researchers in adjusting mix proportions appropriately when designing RAC based on the variation of these factors.

A Study on the Pull-out test for Non-Destructive Evaluation of Concrete Strength (콘크리트 비파괴강도 추정을 위한 인발시험법에 대한 연구)

  • 한만엽;김동욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.639-642
    • /
    • 1999
  • Pullout test known as Lok test among the test methods to evaluate concrete strength strength is a test method which is used to decide the form removal time by assessing the early strength of concrete in a new construction, or to control the quality of newly placed concrete. This method has inconvenience to place inserts on the form work in advance, however, the placing work is quite simple and it has advantage that the strength can be measured at field as long as the inserts are placed. In this study, the first step is to investigate the properties of test method itself, by performing the laboratory test which covers deviation of the method and factors affecting the results, etc. The second step is to correlate the result with cylinder strength and other NDT methods such as rebound hammer, ultrasonic method, etc. And that, the results are compared with foreign results to find the differences between the two. In this research, new factors such as moisture content, area of aggregate failure cross section and area of aggregate separation cross section, etc as well as wate-cement ratio and age are investigated.

  • PDF

An Experimental Study on the Effect of Capping Type of Cylindrical Concrete Specimen on Compressive Strength (원주형 콘크리트 공시체의 캡핑종류별 압축강도 영향)

  • 이상완;김수만;백승종;김광돈;이평석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.167-172
    • /
    • 2000
  • There are a variety of factors affecting measured compressive strength of hardened concrete. One of them is the end surface condition of concrete specimen. So, many capping methods have been developed for the specimen to meet the end condition requirement of ASTM C 39. A series of experimental strength comparison study was carried out using several representative capping methods, including pad capping method which is one of unbonded elastomeric capping system and was newly adopted in the ASTM standard. A comparison was also focused on their economy, convenience, harmfulness, etc.

  • PDF

Study on Compressive Strength of Field-Cast Concrete (현장타설 콘크리트의 압축강도에 관한 연구)

  • 김상효;배규웅
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1989.10a
    • /
    • pp.69-72
    • /
    • 1989
  • It is widely recognized that the strength of reinforced concrete members has characteristics of random variations due to the variability of the mechanical properties of concrete and steel, the dimensional error as well as incorrect placement of reinforcing bars. In those sources of randomness, variations in concrete strength may be the one affecting the strength of R.C. members most. The concrete strength is usually assumed to have large uncertainty due to the variations in many factors, such as material properties, proportions of the concrete mix, methods of mixing, transporting, placing and curing, etc. In this study, the random characteristics inherent in the strength of field-cast concrete have been examined based on the data collected by testing standard cylinders made of field-cast concrete and cured under in-situ condition.

  • PDF

Optimization of mineral admixtures and retarding admixture for high-performance concrete by the Taguchi method

  • Chao-Wei Tang
    • Computers and Concrete
    • /
    • v.32 no.2
    • /
    • pp.185-206
    • /
    • 2023
  • This article aimed to explore the optimization of mineral admixtures and retarding admixture for high-performance concrete. In essence, fresh concrete can be regarded as a mixture in which both coarse and fine aggregates are suspended in a cement-based matrix paste. Based on this view, the test procedure was divided into three progressive stages of binder paste, mortar, and concrete to explore their rheological behavior and mechanical properties respectively. At each stage, there were four experimental control factors, and each factor had three levels. In order to reduce the workload of the experiment, the Taguchi method with an L9(34) orthogonal array and four controllable three-level factors was adopted. The test results show that the use of the Taguchi method effectively optimized the composition of high-performance concrete. The slump of the prepared concrete was above 18 cm, and the slump flow was above 50 cm, indicating that it had good workability. On the other hand, the 28-day compressive strength of the hardened concretes was between 31.3-59.8 MPa. Furthermore, the analysis of variance (ANOVA) results showed that the most significant factor affecting the initial setting time of the fresh concretes was the retarder dosage, and its contribution percentage was 62.66%. On the other hand, the ANOVA results show that the most significant factor affecting the 28-day compressive strength of the hardened concretes was the water to binder ratio, and its contribution percentage was 79.05%.