• Title/Summary/Keyword: factor level

Search Result 9,499, Processing Time 0.039 seconds

Evaluation of the Response Modification Factor for RC Wall-type Structures (철근콘크리트 벽식 구조물의 반응수정계수 평가에 관한 연구)

  • 한상환;이리형;오영훈;천영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.433-438
    • /
    • 1998
  • Design lateral strength calculated by current seismic design code is prescribed to be much lower than the force level required for a structure to respond elastically during design level earthquake ground motion. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factor known as "response modification factor, R". This factor accounts for the inherent ductility, overstrength, redundancy, and damping of a structural system. This study considers ductility and overstrength of the wall-type structure for investigating R factor. This means that R factor is determined from the product of "ductility-based R factor($R_$\mu$$) and overstrength factor($R_s$). $R_$\mu$$ factor is calibrated to attain the targer ductility ratio (system ductility capacity) and produced in the from of $R_$\mu$$ spectra considering the influence of target ductility, natural period, and hysteretic model. On the other hand, $R_s$ is more difficult to quantify, since it depends on both material and system-dependent uncertain parameters. In this study Rs factor was determined from the result of push-over analysis.-over analysis.

  • PDF

Development of the Speed Limit Model for Harbour and Waterway(I) - Considerations Discrimination for Speed Limit Decision - (항만과 수로의 제한속력 설정 모델 개발에 관한 연구(I) - 제한속력 설정을 위한 고려요소 식별 -)

  • Kim, Deug-Bong;Jeong, Jae-Yong;Park, Jin-Soo;Park, Young-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.171-178
    • /
    • 2015
  • This research is the first research on developing the speed limit select model and also it is the result of the research on the importance of each element and consideration factors when selecting the speed limit. For the consideration factor discrimination and calculation of the importance, the delphi method and AHP method was used. The delphi survey was processed through third round survey, 5 high consideration factor(Level 1) and 23 low consideration factor(Level 2) was discriminated. During the process of the third delphi survey, when the CVR cost was in the range between 0.4~1.0 it was treated as the consideration factor when selecting the speed limit and less than 0.4 cost was eliminated. In the process of the second delphi survey, 33 consideration factors were discriminated but was reordered into 23 categories through the third survey. Based on the 23 categories earned through the third delphi analysis, the AHP survey was processed. The result of the AHP survey was that out of the importance of the 5 high consideration factor(Level 1), the traffic condition was evaluated as the number one factor and the vessel condition, waterway condition, environment condition, supporting condition and etc. conditions were evaluated following the traffic condition. Out of the 23 low consideration factor(Level 2) consideration, the visibility was evaluated to be the first important and the performance of the vessel steering, objective factors within the harbor, amount of traffic and density, distance between the passing vessel, speed of the steering capacity and tidal current were the following evaluated factors.

The Impact of Corporate Capabilities on Management Performance : Focusing on the Korean Distribution Industry during the COVID-19 Pandemic

  • Kil-Yong SEONG;Byoung-Goo KIM;Chun-Su LEE
    • Journal of Distribution Science
    • /
    • v.22 no.3
    • /
    • pp.105-112
    • /
    • 2024
  • Purpose: This study analyzed the relationship between corporate capacity and management performance in the Korean distribution industry during the COVID-19 pandemic. Research design, data and methodology: The data for this study used the 2021 KOTRA GCL Test Data, and multiple regression analysis was performed using SPSS 26. As corporate competency, human capital and related capital of intellectual capital theory were utilized, and the global network level of social network theory was also utilized. As an additional analysis, corporate characteristics factors were used. Results: First, the level of global mindset of human capital acted as a positive factor in management performance, and the level of professional manpower did not achieve significant results. Second, related capital acted as a positive factor in corporate performance. Third, from the perspective of social network theory, the global network level of companies acted as a positive factor in management performance. Finally, the relationship between corporate characteristics and management performance was marginally significant. Conclusions: In order to improve the business performance of a company in a market shock such as the COVID-19 pandemic, it is required to strengthen the level of network construction with customers and increase the level of intellectual capital that a company has.

An Analysis on the Satisfaction Level of Specialty Shops for Environment-Friendly Agricultural Products (친환경농산물 전문매장의 서비스품질만족도 분석)

  • Seo, Dong-Woo;Heo, Seung-Wook
    • Korean Journal of Organic Agriculture
    • /
    • v.18 no.3
    • /
    • pp.315-329
    • /
    • 2010
  • This study focused on analysis of the satisfaction level of specialty shops for environment-friendly agricultural products (EFAP). To analyze the satisfaction level of EF AP, a series of household surveys were conducted. Questionnaire was prepared on the basis of the SERVQUAL model and the structural equation modeling was made on the basis of the contents surveyed. The main results of this study are summarized as follows. Firstly, tangibles structured with store clearance, neat uniform, information and others is the factor of service quality satisfaction. Secondly, reliability structured with service practice, problem solving, and service in accurate time is the factor of service quality satisfaction. Thirdly, assurance structured with the reliability of employees, sufficient knowledge of employees, courteous and good manner is the factor of service quality satisfaction. Fourthly, responsiveness structured with prompt service, voluntary help, customer response service and the like is the factor of service quality satisfaction. Fifthly, the sympathy structured in interest for each customer, provision of service in time convenient to use, encountering the customers with genuine feeling are the factors of service quality satisfaction. And sixthly, the service satisfaction factors would influence on the consumer behavior factors.

Influence of Autologous and Homologous Blood Transfusion on Interleukins and Tumor Necrosis Factor-α in Peri-operative Patients with Esophageal Cancer

  • Xing, Yue-Li;Wang, Yan-Chun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7831-7834
    • /
    • 2014
  • Objective: To explore the influence of different ways of blood transfusion on the expression levels of interleukins (IL) and tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) inperi-operative patients with esophageal cancer. Materials and Methods: A total of 80 patients with esophageal cancer who underwent radical operations were selected as study patients and randomly divided into an observation group (treated with autologous blood transfusion) and control group (with homologous blood transfusion). Changes of intra-operative indexes and peri-operative blood indexes, from hemoglobin (Hb) and hematocrit value (Hct), to levels of inflammatory factors like interleukins-6 (IL-6), IL-8, IL-10 and tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) were compared. Results: Operations for patients in both groups were successfully conducted, and no significant differences in mean surgical duration and intra-operative hemorrhage volume, fluid infusion volume and blood transfusion volume were detected (p>0.05). Compared with values before surgery, Hb and Hct levels decreased significantly while white blood cell count (WBC) increased 1, 5 and 7 d after operation (p<0.05, p<0.01). In addition, WBC was apparently higher in observation group than in control group 5 and 7 d after operation (p<0.01). Compared with before surgery, in the observation group, levels of IL-6, IL-8 and IL-10 had no significant differences after operation (P>0.05), but TNF-${\alpha}$ level increased y (p<0.01), whereas in control group, IL-6 level had no significant difference (p>0.05), IL-8 level decreased obviously (p<0.05), IL-10 level increased markedly first and then decreased gradually as time passed but its level remained elevated (p<0.01), and TNF-${\alpha}$ level increased first and then decreased, and there was no significant difference 7 d after operation (p>0.05). Conclusions: Decreased IL-8 and increased IL-10 levels are two important reasons for immunosuppression after homologous blood transfusion, whereas autologous blood transfusion can alleviate this while increasing the TNF-${\alpha}$ level, which also has potential to improve anti-tumor immunity in the human body.

Comparison and The Evaluation of Criteria for Arousal Level Control (SIC에 의한 각성도 제어를 위한 평가기준의 설정 및 비교)

  • Ko, H.W.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.372-376
    • /
    • 1996
  • This paper describes the criterias to evaluate arousal states of subject and these are applied to contort arousal level. Correction factor was introdued to compensate under or over evaluated Nz due to the different initial basal skin impedance. These criteria and correction factor were worked well to increase the arousal level.

  • PDF

Streptomyces griseus HH1, An A-factor Deficient Mutant Produces Diminished Level of Trypsin and Increased Level of Metalloproteases

  • Kim, Jung-Mee;Hong, Soon-Kwang
    • Journal of Microbiology
    • /
    • v.38 no.3
    • /
    • pp.160-168
    • /
    • 2000
  • A-factor I a microbial hormone that can positively control cell differentiation leading to spore formation and secondary metabolite formation in Streptomyces griseus. to identify a protease that is deeply involved in the morphological and physiological differentiation of Streptomyces, the proteases produced by Streptomyces griseus IFO 13350 and its A-factor deficient mutant strain, Streptomyces griseus HH1, as well as Streptomyces griseus HH1 transformed with the afsA gene were sturdied. In general Streptomyces griseus showed a higher degree of cell growth and protease activity in proportion to its ability to produce a higher amount of A-factor. In particular, the specific activity of the trypsin of Streptomyces griseus IFO 13350 was greatly enhanced more than twice compared with that of Streptomyces griseus HH1 in the later stage of growth. The specific activity of the metalloprotease of Streptomyces griseus HH1 was greatly enhanced more than twice compared with that of Streptomyces griseus IFO 13350, and this observation was reversed in the presence of thiostreptione, However, Streptomyces griseus HH1 transformed with the afsA gene showed a significantly decreased level of trypsin and metalloprotease activity compared with that of the HH1 strain. There was no significant difference between Streptomyces griseus IFO 13350 and HH1 strain in their chymotrypsin and thiol protease activity, yet the level of leu-amionpeptidase activity was 2 times higher in Streptomyces griseus HH1 than in strain IFO 13350 . Streptomyces griseus HH1 harboring afsA showed a similar level of enzyme activity , however, all the three protease activities sharply increased and the thiol protease activity was critically increased at the end of the fermentation. When a serine protease inhibitor, pefabloc SC, and metalloprotease inhibitor, EDTA, were applied to strain IFO 13350 to examine the in vivo effects of the protease inhibitors on the morpholofical differentiation, the formation of aerial meycelium and spores was delayed by two or three days.

  • PDF

An Analysis of the Image Factor and Combination of Xi'an Castle Park in China (중국 서안시 성곽공원의 이미지 요인 및 조화도 분석)

  • Kim, Dong-Chan;Ma, Yuan
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.105-111
    • /
    • 2010
  • This research aims to grasp the main factors of the image of Xi'an Ming City Wall Park and the harmony level with city walls and moat based on citizen's consciousness to improve the future design, field survey and the POE method are employed to analyze the image factor and harmony level of the Xi'an Ming City Wall Park. In the literature survey, the related materials were collected to obtain the most useful information for references, POE study of the Xi'an Ming City Wall Park were conducted. The instrument for survey is a questionnaire that includes a portion of questions regarding Xi'an Ming City Wall Park and the design intention of the surroundings of city wall. Data were analyzed using the Statistical Package for the Social Science (SPSS17.0 for Windows). Multiple regression analysis, and correlation analysis were employed along with the use of general descriptive data analysis. The factor analysis of the image of Xi'an Ming City Wall Park identified three factors, "environment" factor, "convenience" factor, "cultural aesthetics" factor, and the most important factor is "environment" factor. Among 14 landscape elements, paving, garden architectures and entrance spaces were identified as important variables which significantly affect the overall level of harmony with the city wall, and the space for rest; waterscape and paving were identified as important variables which significantly affect the overall level of harmony with the moat.

Effects of Extracellular Signaling on the Endogenous Expression of Self-Renewal-Stimulating Factor Genes in Mouse Embryonic Stem Cells

  • Gong, Seung-Pyo;Lee, Seung-Tae
    • Reproductive and Developmental Biology
    • /
    • v.36 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • In order to provide the basis for developing practical mouse embryonic stem cells (mESCs) culture method, how the endogenous level of self-renewal-stimulating factor genes was altered in the mESCs by different extracellular signaling was investigated in this study. For different extracellular signaling, mESCs were cultured in 2 dimension (D), 3D and integrin-stimulating 3D culture system in the presence or absence of leukemia inhibitory factor (LIF) and transcriptional level of $Lif$, $Bmp4$ and $Wnt3a$ was evaluated in the mESCs cultured in each system. The expression of three genes was significantly increased in 3D system relative to 2D system under LIF-containing condition, while only $Wnt3a$ expression was increased by 3D culture under LIF-free condition. Stimulation of integrin signaling in mESCs within 3D system with exogenous LIF significantly up-regulated transcriptional level of $Bmp4$, but did not induce transcriptional regulation of $Lif$ and $Wnt3a$. In the absence of LIF inside 3D system, the expression of $Lif$ and $Bmp4$ was significantly increased by integrin signaling, while it significantly decreased $Wnt3a$ expression. Finally, the signal from exogenous LIF significantly caused increased expression of $Lif$ in 2D system, decreased expression of $Bmp4$ in both 2D and 3D system, and decreased expression of $Wnt3a$ in integrin-stimulating 3D system. From these results, we identified that endogenous expression level of self-renewal-stimulating factor genes in mESCs could be effectively regulated through artificial and proper manipulation of extracellular signaling. Moreover, synthetic 3D niche stimulating endogenous secretion of self-renewal-stimulating factors will be able to help develop growth factor-free maintenance system of mESCs.

Structural safety factor for small unmanned aircraft (소형 무인기 구조 안전계수)

  • Kim, Sung-Joon;Lee, Seung-gyu;Kim, Tae-Uk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.25 no.2
    • /
    • pp.12-17
    • /
    • 2017
  • Manned aircraft structural design is based on structural safety factor of 1.5, and this safety factor is equivalent to a probability of failure of between 10-2 and 10-3. The target failure probability of FARs is between 10-6 and 10-9 per flight according to aircraft type. NATO released STANAG 4703 to established the airworthiness requirements for small UAV which is less than 150kg. STANAG 4703 requires the Target Level of Safety according to MTOW. The requirements of failure probability for small UAV is between 10-4 and 10-5. In this paper, requirements of airworthiness certification for small UAV were investigated and the relationship of safety factors to the probability of structural failure is analyzed to reduce measure of safety factor and structural weight of unmanned aircraft.