• Title/Summary/Keyword: facility standard

Search Result 930, Processing Time 0.026 seconds

Best Measurement Capability and Standard Test Facility for the Water-level Gauges (수위계 표준시험장치 개발 및 최고측정능력에 관한 연구)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.10
    • /
    • pp.1012-1017
    • /
    • 2007
  • Rain data and water-level data are importantly used for dam operation at flood period. Because dams are directly controlled by the water-level data, the characteristic of the water-level gauges is necessary to be managed. Thus, we developed the standard test facility and method for testing the water-level gauges which are a float type, a supersonic type and a radar type. And we calculated the uncertainty of the standard test facility to maintain the accuracy of water-level gauges. Through development of this facility, we could obtain the characteristics and the calibration factor of the water-level gauges. And, this study showed that the standard test facility can be widely used for dam operation and basin management.

Standardization for receive and supply of electric power facility of airport (공항 수.배전 설비 표준화)

  • 최홍규;원진희;송영주;조계술
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.349-354
    • /
    • 2003
  • Airport facility is infrastructure that become external creditworthiness and linear measure of country competitive power. Among them, receive and supply of electric power facility of airport is very important in peculiarity, trustability, safety side of airport. In this parer, sorted domestic airline as 4 classes by code to accomplish standardization for receive and supply of electric power facility of airport. And established justice and coverage about receive and supply of electric power facility using without any standard present and analyze problem for receive and supply of electric power facility of existing airport and presents standard. Finally, present standard single-line diagram by airport grade and system grade standard of receive and supply of electric power facility of airport.

  • PDF

A Study on the Application of Facility Standard of Rural Public Health Center to city Public Health Center with a Focus on Area Ratio (면적구성을 중심으로 한 농어촌 보건소 표준시설 기준의 도시 보건소 적용에 관한 연구 - 대구광역시 보건소를 중심으로 -)

  • 이용광
    • Korean Institute of Interior Design Journal
    • /
    • no.40
    • /
    • pp.102-108
    • /
    • 2003
  • Currently, there is no facility standard for a city public health center. The facility standard of rural public health center is referred to architectural plan of city public health center. This study is about architectural plan of the city public health center and have been in 7 public health centers in Daegu investigated. Conclusions can be summarized as follows: 1) The Mother and child hygienic section, area ratio which is presented by the facility standard of rural public health center must be increased in case of city public health center since function-reinforcement of the mother and child hygienic section is required. 2) Business section, the area ratio which is presented by the facility standard of rural public health center must be diminished for city public health center because it has been excessively allocated.

The global standard realizing process of the Automobile Assembly Facility

  • Nashimoto, Tomoo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.24-25
    • /
    • 2015
  • To realize the global standard of the assembly facility, one of key point is an influence of local characteristic. The global standardized information could be a useful input, especially at the beginning stage of the project. The content should be carefully checked against local requirements, in order to develop an Assembly Facility design to meet local regulations & characteristics. The level of input information required in each step is different depend on regions & countries. At an execution stage of the project, the global standard input needs to be updated as customized final input for the construction. There will be many issues to be clarified and coordinated so that the Assembly facilities meet the final requirements for the production technology. As a result, it is important to understand the timing to use the global standard information and the contents what is needed to adapt to the local characteristics. And close collaboration between production technology team and facility team is always required.

  • PDF

Design of Standard Facility Interface for Efficient Building Control (효율적인 빌딩 관제를 위한 표준설비 인터페이스 설계)

  • Moon, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.334-337
    • /
    • 2021
  • Recently, the necessity of rapid response to social problems such as disasters and quarantine arising from the complex and diverse social structures has emerged. As the number of large buildings increases, large-scale human damage is expected in the event of a disaster such as fire. To solve this problem, efficient control must be achieved through interfacing with various equipment and facilities installed inside the building. In this paper, we intend to study the interface method for various facilities in the building for efficient control. In detail, the facility standard model is defined by examining the status and specification of building. In addition, we intend to design and propose a standard facility communication data frame to support the protocol applicable to this model.

A Study on the Facility Standard of Herbal Dispensaries (탕전실의 시설 기준에 대한 연구)

  • Kim, Ji-Hoon;Kim, Yun-Kyung
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.81-92
    • /
    • 2017
  • Objectives: Herbal dispensaries can be installed separately from medical institutions. This study was done to suggest directions of regulation on management of externally installed herbal dispensaries. Methods: In this study, we visited and investrigated 7 representative herbal dispensaries to understand current status of herbal dispensaries. After comprehending current domestic regulations on herbal dispensaries, we referred "Management Practice on Dispensary Facility of Traditional Chinese Medicine in Medical Institution", "Enforcement Rule of Decree on Institution Standard of Manufacturing and Importation for Drugs, etc." and "Enforcement Rule of Food Sanitation Act" to suggest improved regulations for herbal dispensaries. Results: We suggested reasonable regulations for facility standards including location of building, dispensary room, water supply facility, lavatory and storage facility, etc.. Conclusions: We hope that results of this study could be baseline data for developing regulations on facility standards of herbal dispensaries.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

A Study on Management System for Improving of Equipment Productivity in Injection Machining Process (사출가공공정에서 설비생산성 향상을 위한 관리체계에 대한 연구)

  • Park, Jun-Byung;Bae, Young-Ju
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.219-226
    • /
    • 2017
  • This study investigates application cases of facility management system model for enhancing facility productivity of industry filed around medium and small facility processing companies and finds the inefficiency of the existing management model. Following items are researched to seek out methods and measures to maximize facility productivity through empirical analysis by exploring and establishing a new management model. First, the empirical analysis, it is found that the overall equipment efficiency index used for facility productivity management in the companies has a difficulty being used as the index for it in actual medium-small processing companies. Second, a new facility management system model applying standard cycle time is suggested among facility management index system to measure facility productivity. Third, the empirical analysis is used to verify that developed facility management system model is a useful method to manage the facility productivity by applying the model to actual medium-small processing companies. Finally, it is necessary to implement comparison analysis on whether actual productivity enhancement induces a distinctly different result by using a new facility management index system model to be inhibited in this study.

Standard Classification System of Marine Research Facility and Equipment for an Integrated Management (통합관리를 위한 해양연구시설·장비 표준분류체계)

  • RHO, TAEKEUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.25 no.4
    • /
    • pp.132-159
    • /
    • 2020
  • As multidisciplinary marine research is actively conducted, various types of marine research facilities and equipment are purchased every year. However, among marine research facilities and equipment, it is difficult to classify and manage various types of field observation equipment used for environmental data collection and sample collection under the current national research facility and equipment standard classification system. In the case of Korea Institute of Ocean Science and Technology, about 30% of research facilities and equipment are unclassified and not properly managed. In this study, marine research facilities and equipment are classified into 7 middle and 36 sub-classes according to their characteristics. It is proposed to add a large classification group called 'Environmental Observation/Analysis Equipment', to the national research facility equipment standard classification system. In addition, it is proposed to classify the equipment operated in the laboratory among marine research facilities and equipment according to the existing national research facility equipment standard classification system. Through this, it is expected that all of Korea's marine-related research facilities and equipment can be systematically classified and managed effectively.

Analysis of Facility Standard for Elderly Welfare Facility by Universal Design Principle and Guideline: Focusing on Legal Regulations (유니버설 디자인의 원리와 지침에 의한 노인복지시설 기준 분석: 법률 규정을 중심으로)

  • Kim, Soo-Jung
    • Journal of Industrial Convergence
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • The purpose of this study is to analyze the facility standards of the elderly welfare facilities applying the seven principles of the universal design. The facility standards of the elderly welfare facilities were limited to the provisions of the "Enforcement Regulation of the Elderly Welfare Act". There are few legal regulations applying the universal design in the construction of the elderly welfare facilities. The facility standards are set only with the minimum requirements such as securing the safety of the user, securing the space area, functional convenience, and risk prevention. However, the contents of the regulations are limited to the minimum standards for functional convenience and safety required for living. In conclusion, in the elderly welfare facilities, the notion of universal design, which considers not only the elderly, but also service providers, employees, and general visitors, should be considered.

  • PDF