• 제목/요약/키워드: facility condition monitoring

검색결과 67건 처리시간 0.026초

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

화학설비 시스템의 이상고장진단을 위한 Expert System의 개발 (Development of Expert System for the Fault Diagnosis of Chemical Facility System)

  • 오재응;신준;신기홍;김두환;김우택;이충휘
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.639-642
    • /
    • 2000
  • Chemical facility system have dangerous elements that can injure the human like an explosion and a fire, gas poisoning by a leakage of the harmful chemical material. In addition to a vibration of the machine occurs the leakage. Therefore, the chemical factory requires for periodic monitoring of the vibration. But, until now, the operator has executed a monitoring of the machine by the senses. So, the diagnostic expert system by which the operator can judge easily and expertly a condition of the machine is developed. This paper describes the structure of diagnostic system and the diagnostic algorithm using fuzzy inference

  • PDF

Deep-learning-based system-scale diagnosis of a nuclear power plant with multiple infrared cameras

  • Ik Jae Jin;Do Yeong Lim;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.493-505
    • /
    • 2023
  • Comprehensive condition monitoring of large industry systems such as nuclear power plants (NPPs) is essential for safety and maintenance. In this study, we developed novel system-scale diagnostic technology based on deep-learning and IR thermography that can efficiently and cost-effectively classify system conditions using compact Raspberry Pi and IR sensors. This diagnostic technology can identify the presence of an abnormality or accident in whole system, and when an accident occurs, the type of accident and the location of the abnormality can be identified in real-time. For technology development, the experiment for the thermal image measurement and performance validation of major components at each accident condition of NPPs was conducted using a thermal-hydraulic integral effect test facility with compact infrared sensor modules. These thermal images were used for training of deep-learning model, convolutional neural networks (CNN), which is effective for image processing. As a result, a proposed novel diagnostic was developed that can perform diagnosis of components, whole system and accident classification using thermal images. The optimal model was derived based on the modern CNN model and performed prompt and accurate condition monitoring of component and whole system diagnosis, and accident classification. This diagnostic technology is expected to be applied to comprehensive condition monitoring of nuclear power plants for safety.

국립공원 시설모니터링 변화추이 분석 (Trend Analysis on Facility Monitoring of Korea National Parks)

  • 이주희;배민기;심규원
    • 한국산림과학회지
    • /
    • 제99권4호
    • /
    • pp.487-500
    • /
    • 2010
  • 본 연구의 목적은 3회에 걸쳐 국립공원 시설 모니터링 결과에 대한 변화 추이를 분석하여 국립공원 시설 관리정책 방향을 제시하는 것이였다. 분석결과, 산악형 국립공원은 대부분의 시설에서 중요도와 성취도 평가값 모두가 지속적으로 증가하는 추세를 나타내고 있었다. 연도별 중요도-성취도 분석결과 추이를 볼 때, 우선시정이 필요한 시설물은 주차장의 위치와 수용능력, 화장실의 수로 나타났다. 해상해안형 국립공원의 야영장, 해안 시설의 성취도가 지속적으로 증가한 것으로 나타났다. 연도별 중요도-성취도 분석결과 추이를 볼 때, 우선시정이 필요한 시설물은 화장실의 위치, 수, 청결도, 탐방로의 안전성과 노면상태, 난간 및 주의 안내판 설치, 안내정보 제공, 음수대 및 샤워장 관리상태로 나타났다. 본 연구결과는 각 국립공원별로 공원시설과 관련된 탐방객의 요구사항 및 경향을 지속적으로 파악하여 공원시설 설치 및 유지관리를 통한 탐방만족도 증진과 국립공원의 시설업무 정책방향을 설정하는데 도움을 줄 수 있을 것이다.

대형 풍력터빈을 위한 무인 원격감시시스템 개발 (Development of Unmanned Remote Monitoring System for MW Class Wind Turbines)

  • 박준영;김범주;이재경
    • 제어로봇시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.412-418
    • /
    • 2011
  • The scale of wind turbines has continuously increased over the last decade. Especially, the rapid growth of the rotor diameter has brought about the increase of the tower height and the load on the rotor blade, as can be seen in the case of a 5MW class wind turbine with 126m rotor diameter. This trend means the increasing possibility of system failure. In addition to that, it is impossible for human operators to stay and manage all the turbines in the case of a large-scale wind farm. For these reasons, the operation and maintenance technology is getting more importance. In this paper, we present an unmanned remote monitoring system for MW class wind turbines and its application to YeungHeung wind test bed.

A Study on the Trolley Sliding Condition Inspection System

  • Chang, ChinYoung;Kim, ChanSam;Jung, NoGeon;Na, YeonIl;Kim, YangSu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.109-112
    • /
    • 2015
  • The Korean electric railway is growing rapidly such as speed of 300km/h in high speed section and 230km/h in the conventional railway section. But, power supply failure occurs because of loss of contact, defective catenary system and high speed vehicle. Therefore preventive maintenance way based reliability has been applied. Typical example is the facility inspection method using trolley inspection system. But it is required differentiated inspection method to prevent problem such as inspection errors. In this paper, a study on the trolley sliding condition inspection system using monitoring techniques is performed for performance enhancement of inspection system. It proposed the efficient maintenance method through monitoring the deviation and height of contact wire after installing inspection system on the top of train which operates in the metropolitan area. Inspection errors were decreased by virtually monitoring the video of faulty facilities. Also those facilities were identified through the impact sound analysis and tests at the main catenary section.

수력발전소 정비변수 및 회전체 통합관리 시스템 개발 (Development of an Integrated Management System for Maintenance Parameters and Rotary Machine of Hydro-power Plant)

  • 신성환;박진호;윤두병
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.263-269
    • /
    • 2012
  • Condition-based maintenance (CBM) has been used as a useful concept for optimizing maintenance plan and decreasing maintenance cost in several kinds of plant sites. This study introduced an example that developed an integrated management system for maintenance parameters and hydraulic turbine of hydro-power plant in order to improve its maintenance system as applying CBM techinique. The integrated management system consists of three parts. One is a hardware part including PDA inspection system and several kind of precision measuring instruments. Another is a vibration monitoring system on hydraulic turbine. The other is a software part that takes charge of making hierarchy tree of maintenance parameters and their inspection route, managing accumulated database, assessing health condition of components, and supporting interface with other enterprise management system. The system has been installed at Chuncheon Hydro-power plant for test and demonstration. It is expected that the system can contribute database construction for diagnostics and prognostics on facility health condition and systematic accumulation of know-how on operation and maintenance of plant.

  • PDF

수력발전소 정비변수 및 회전체 통합관리시스템 개발 (Development of an Integrated Management System for Maintenance Parameters and Rotary Machine of Hydro-power Plant)

  • 신성환;박진호;윤두병;손기성
    • 한국소음진동공학회논문집
    • /
    • 제22권6호
    • /
    • pp.574-581
    • /
    • 2012
  • Condition-based maintenance(CBM) has been used as a useful concept for optimizing maintenance plan and decreasing maintenance cost in several kinds of plant sites. This study introduced an example that developed an integrated management system for maintenance parameters and hydraulic turbine of hydro-power plant in order to improve its maintenance strategy as applying CBM techinique. The integrated management system consists of three parts. One is a hardware part including PDA inspection system and several kind of precision measuring instruments. Another is a vibration monitoring system on hydraulic turbine. The other is a software part that takes charge of making hierarchy tree of maintenance parameters and their inspection route, managing accumulated database, assessing health condition of components, and supporting interface with other enterprise management system. The system has been installed at Chuncheon hydro-power plant for test and demonstration. It is expected that the system can contribute database construction for diagnostics and prognostics on facility health condition and systematic accumulation of know-how on operation and maintenance of plant.

음식물쓰레기 단독 퇴비화 및 음식물쓰레기와 하수 슬러지의 혼합 퇴비화에 따른 퇴비화시설의 운전특성 (Operating Characteristics of Composting Facility during Composting of Food Waste and Co-composting of Food Waste and Sewage Sludge)

  • 남궁완;이노섭;박준석;인병훈;허준무;박종안
    • 한국환경보건학회지
    • /
    • 제28권5호
    • /
    • pp.86-92
    • /
    • 2002
  • This study was performed to assets the operating characteristics of food waste composting and co-composting (food waste + sewage sludge) at a compelling facility. The facility was being operated successfully without being affected by kind of composting feed materials. Partial anaerobic condition was detected during food waste composting and co-com-posting, but these two composting systems were proven to be operated successfully under aerobic condition from the monitoring results of $O_2$, volatile solids reduction rate, temperature, and other parameters. The conductivity and chloride concentrations of compost were gradually increased during two composting periods, but the conductivity and chloride concentrations of co-compelling indicated lower values than those of food waste composting at final point(40 m). As a result, co-composting was turned out to be more desirable than food waste composting, considering salt problem. High correlations ($R^2$= 0.9265 for food waste composting and $R^2$= 0.9685 for co-composting) between CEC and volatile organic matter were found. Quality of composts produced from two composting process satisfied Korean heavy metal standard.

Check Valve 상태감시를 위한 통신 및 센서신호처리 기능 구현 (Realization of Communication and Sensor Signal Processing Technique for Condition Monitoring of Check Valve)

  • 전정섭;조재근;김정수;유준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.223-226
    • /
    • 2003
  • This paper presents a realization of sensor signal processing(noise filtering) and Fieldbus based communication for condition monitoring of check valve. we first acquired the AE(Acoustic Emission) sensor data at the KAERI check valve test loop, and their frequencies were analyzed to find the informative band. To reject background noises, bandpass filters have been designed. Also, to send the processed data to a remote site, wired communication facility has been realized via DeviceNet.

  • PDF