• 제목/요약/키워드: facial scan

검색결과 107건 처리시간 0.021초

비골골절의 진단시 전산화단층촬영의 유용성 (The Value of Facial Bone CAT Scan in the Diagnosis of the Nasal Bone Fracture)

  • 민경희;홍성희;이종훈
    • Archives of Plastic Surgery
    • /
    • 제33권4호
    • /
    • pp.440-444
    • /
    • 2006
  • Purpose: The nasal bone fracture is the most common type of facial bone fracture. In making a diagnosis, physical findings are much more important than the simple radiologic findings. Facial bone CAT scan can provide the accurate diagnosis and the correct location of nasal bone fractures, so it can be lessoned with proper intervention. The aim of this study was to evaluate the usefulness of facial bone CAT scan in the diagnosis of nasal bone fractures. Methods: The medical records and facial bone CAT scan of 45 patients clinically suspected nasal bone fracture but was not diagnosed on simple radiologic findings were analyzed. Results: All of the 45 patients were confirmed as nasal bone fractures in the facial bone CAT scan. The most common cause of fracture was assault. The mean age was 23.2 years. Physical findings were tenderness (100%), swelling(93.3%), epistaxis(66.6%), deviation (42.2 %), external wound(17.7%) and crepitus(4.4%) in order. Conclusions: It was concluded that the simple radiologic findings can not be conclusive, where the physical findings indicate a suspected nasal bone fracture. The facial bone CAT scan was more reliable for the correct diagnosis and follow-on treatment.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

거리맵을 이용한 3차원 얼굴 스캔 데이터와 CBCT 데이터의 정확한 정합 기법 (Accurate Registration Method of 3D Facial Scan Data and CBCT Data using Distance Map)

  • 이정진
    • 한국멀티미디어학회논문지
    • /
    • 제18권10호
    • /
    • pp.1157-1163
    • /
    • 2015
  • In this paper, we propose a registration method of 3d facial scan data and CBCT data using voxelization and distance map. First, two data sets are initially aligned by exploiting the voxelization of 3D facial scan data and the information of the center of mass. Second, a skin surface is extracted from 3D CBCT data by segmenting air and skin regions. Third, the positional and rotational differences between two images are accurately aligned by performing the rigid registration for the distance minimization of two skin surfaces. Experimental results showed that proposed registration method correctly aligned 3D facial scan data and CBCT data for ten patients. Our registration method might give useful clinical information for the oral surgery planning and the diagnosis of the treatment effects after an oral surgery.

3D Facial Scanners: How to Make the Right Choice for Orthodontists

  • Young-Soo Seo;Do-Gil Kim;Gye-Hyeong Lee;Kyungmin Clara Lee
    • Journal of Korean Dental Science
    • /
    • 제17권1호
    • /
    • pp.1-13
    • /
    • 2024
  • With the advances of digital scanning technology in dentistry, the interests in facial scanning in orthodontics have increased. There are many different manufacturers of facial scanners marketing to the dental practice. How do you know which one will work best for you? What questions should you be asking? We suggest a clinical guideline which may help you make an informed decision when choosing facial scanners. The characteristics of 7 facial scanners were discussed in this article. Here are some considerations for choosing a facial scanner. *Accuracy: For facial scanners to be of real value, having an appropriate camera resolution is necessary to achieve more accurate facial image representation. For orthodontic application, the scanner must create an accurate representation of an entire face. *Ease of Use: Scanner-related issues that impact their ease of use include type of light; scan type; scan time; file type generated by the scanner; unit size and foot print; and acceptance of scans by third-party providers. *Cost: Most of the expenses associated with facial scanning involve the fixed cost of purchase and maintenance. Other expenses include technical support, warranty costs, transmission fees, and supply costs. This article suggests a clinical guideline to make the right choice for facial scanner in orthodontics.

Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석 (Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method)

  • 강수홍;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

양측 교대형 안면신경 마비의 치험 -증례 보고- (Bilateral Alternating Bell's Palsy Treated with Stellate Ganglion Block -A case report-)

  • 우영철;구길회
    • The Korean Journal of Pain
    • /
    • 제11권2호
    • /
    • pp.326-331
    • /
    • 1998
  • Facial nerve paralysis is a common pain clinical diagnosis. But ipsilateral or contralateral recurrent facial paralysis is found in about 2.6~19.5% of facial paralysis and especially bilateral facial paralysis is rare. While idiopathic facial paralysis is the most common diagnosis, a comprehensive evaluation must be completed prior to this diagnosis in patients with bilateral facial paralysis. A representative case of bilateral alternating facial paralysis treated with stellate ganglion block (SGB) is presented. A 57 years old male patient who had the onset of a right facial paralysis 7 months ago visited pain clinic. Five months after the onset of right facial paralysis, as it was improving, he developed a left facial paralysis. He had history of hypertension, diabetus mellitus and pain episode on mastoid process before facial paralysis developed. Electrical test showed incomplete neuropathy on both side and computed tomography (CT) scan was normal. He was treated with SGB, physical theraphy and aspirin medication. After 25 times SGB, he was recovered almost completely.

  • PDF

동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례 (Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports)

  • 구필준;최유성;이종혁;하승룡
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.328-343
    • /
    • 2023
  • 최근 삼차원적 안면 스캔 (facial scan) 및 악운동 (jaw motion) 등의 데이터를 통합하여 동적 교합을 나타내는 가상 환자를 형성함으로써 심미적인 전치부 고정성 보철물을 제작하는 방법이 소개되고 있다. 이를 통해 진단과정에서 환자와의 원활한 소통이 가능하며, 심미적인 보철 치료의 예지성을 높일 수 있고, 교합조정의 가능성을 낮출 수 있다. 본 증례에서는 상악 전치부 심미 보철 수복이 필요한 환자에서 구강 스캔 데이터와 삼차원 (3D) 안면 스캔데이터, 환자의 악운동 기록을 computer-aided design (CAD) 소프트웨어 상에서 통합하여 동적 교합을 나타내는 가상 환자를 형성하였다. 이를 통해 치료의 결과를 시뮬레이션하고 심미적인 상악 전치부 고정성 보철물을 제작 및 수복하였다. 또한, 안정적인 교합관계를 회복하고 적절한 전방유도가 형성되었는지 확인하기 위하여 각각 치료 단계별로 환자의 교합을 비교 평가하였으며 심미적, 기능적으로 만족스러운 결과를 보였기에 이를 보고하는 바이다.

A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device

  • Liya Ma;Fei Liu;Jiansong Mei;Jiarui Chao;Zhenyu Wang;Jiefei Shen
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권1호
    • /
    • pp.11-21
    • /
    • 2023
  • PURPOSE. To compare the sagittal condylar inclination (SCI) in dentate individuals measured by the different methods with mechanical articulator (MA), virtual articulator (VA), and a jaw tracking device (JTD) system. MATERIALS AND METHODS. A total of 22 healthy dentate participants were enrolled in this study. For MA workflow, the SCI was obtained by a semi-adjustable articulator with protrusive interocclusal records. The SCI was also set on a VA by aligning intraoral scan (IOS) with cone beam computed tomography (CBCT) and facial scan (FS), respectively. These virtual workflows were conducted in a dental design software, namely VAIOS-CBCT and VAIOS-FS. Meanwhile, a JTD system was also utilized to perform the measurement. Intraclass correlation was used to assess the repeatability within workflows. The bilateral SCI values were compared by Wilcoxon matched-pairs signed rank test for each workflow, and Kruskal-Wallis test and post hoc p-value Bonferroni correction were used to compare the differences among four workflows. The agreement of VAIOS-CBCT, VAIOS-FS, and JTD compared with MA was evaluated by Bland-Altman analysis. RESULTS. Intraclass correlation of the SCI revealed a high degree of repeatability for each workflow. There were no significant differences between the left and right sides (P > .05), except for VAIOS-CBCT (P = .028). Significant differences were not found between MA and VAIOS-FS (P > .05). Bland-Altman plots indicated VAIOS-CBCT, VAIOS-FS, and JTD were considered to substitute MA with high 95% limits of agreement. CONCLUSION. The workflow of VAIOS-FS provided an alternative approach to measure the SCI compared with MA.

두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정 (Effective Dose Determination From CT Head & Neck Region)

  • 윤재혁;이광원;조영기;최지원;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권2호
    • /
    • pp.105-116
    • /
    • 2011
  • 두경부(Head & Neck) CT(Computed Tomography)검사에서 환자가 받는 피폭선량 측정을 위하여 인체등가물질로 만든 Rando phantom과 유리선량계를 이용하여 두경부 검사에 따른 환자의 흡수선량의 변화를 실험을 통하여 연구하였다. 인체두부모형을 안와신경(optic nerve), 교뇌(pons), 소뇌(cerebellum), 갑상선(thyroid)으로 나누어, 두경부(Head & Neck) 부위의 검사를 단독검사(Brain, 3D Facial, Temporal, Brain Angiography, 3D Cervical Spine)와 복합검사(Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spin+Angiography)로 구분하여 유효선량의 변화를 실험한 후 결과를 측정하였다. 단순 Brain검사와 Brain Angio검사에는 optic nerve에 유효 선량이 높게 분석되었으며, 또한 Temporal검사에는 Pons에, 3D facial 검사와 3D Cervical Spin검사에는 thyroid의 유효선량 값이 높게 나타났다. 복합적으로 이루어는 검사 중 두경부의 Brain+Brain Angio의 검사는 cerebellum의 부위, Brain+3D facial 검사와 Brain+3D Cervical Spin의 복합검사는 thyroid의 부위, Brain+Temporal의 검사에는 pon's 부위 유효 선량 값이 높게 나타났다. Brain +3D facial +Temporal의 복합검사와 Brain+3D Cervical Spin+Angio의 복합검사는 thyroid의 부위에 유효 선량 값이 높게 분석 되었다. 본 연구 결과 Brain+3D Cervical Spin+Brain Angio 복합검사인 경우의 유효 선량은 2.51858 mSv로 일반인의 연간 유효선량한도 1 mSv의 피폭을 초과하는 결과가 나왔다. 또한, Brain 단순 검사 시 optic nerve는 0.31312 mSv의 유효선량으로 향후 방사선학 검사가 이루어질 경우, 두경부의 일반인의 연간 유효선량을 훨씬 초과할 것이라 사료된다. 따라서 진료의 필요성에 의해서 시행되는 CT검사일지라도 질환 병변의 특성에 맞게 CT촬영조건 변화를 주면서 환자의 피폭선량을 최소한으로 할 수 있는 다양한 검사방법의 연구가 필요하다고 사료된다.

탈모 환자의 적외선 체열 진단상 안면부 체열 특성 (Infrared Thermographic Imaging in Patients with Alopecia)

  • 이태후;문정배;안경애;이혜정
    • 대한한의학회지
    • /
    • 제27권2호
    • /
    • pp.244-252
    • /
    • 2006
  • Objectives : To examine any potential relationships between the types of alopecia and the facial heat distribution in patients with alopecia. Methods : 183 patients with alopecia participated in this study to provide facial heat distribution measured by the Infrared Thermography Scanner (ITS, Nec San-ei Instruments Ltd, Japan). The thermography scan was used in a light- and heat-protected room after 20 minutes' of rest. 1.5m of distance was maintained between the patients and the scanner. Results : Specificity in the type of facial heat distribution was found as follow. 1. Types of facial heat distribution can be classified as T-type and diffused patterns. 2. There was a significant difference in the pattern of facial heat distribution among different types of alopecia (p=0.002): facial heat distribution appeared T-type in androgenic alopecia, alopecia areata, and telogen effluvium (71.3%, 85.7%, 70.4%), whereas diffused pattern was dominant in seborrheic alopecia (55.6%). 3. There was a significant difference in the pattern of facial heat distribution between men and women (p<0.001) : While the T-type and diffused type appeared equally in men (50.6% : 49.4%), T-type was dominant in women (88.0% vs. 12.0%). Conclusions : We conclude that the pattern of facial heat distribution differs depending on the types of alopecia and gender. These differences may provide useful information for diagnosis and clinical therapy for this population.

  • PDF