• Title/Summary/Keyword: eye size

Search Result 338, Processing Time 0.024 seconds

Skew correction of face image using eye components extraction (눈 영역 추출에 의한 얼굴 기울기 교정)

  • Yoon, Ho-Sub;Wang, Min;Min, Byung-Woo
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.71-83
    • /
    • 1996
  • This paper describes facial component detection and skew correction algorithm for face recognition. We use a priori knowledge and models about isolated regions to detect eye location from the face image captured in natural office environments. The relations between human face components are represented by several rules. We adopt an edge detection algorithm using sobel mask and 8-connected labelling algorith using array pointers. A labeled image has many isolated components. initially, the eye size rules are used. Eye size rules are not affected much by irregular input image conditions. Eye size rules size, and limited in the ratio between gorizontal and vertical sizes. By the eye size rule, 2 ~ 16 candidate eye components can be detected. Next, candidate eye parirs are verified by the information of location and shape, and one eye pair location is decided using face models about eye and eyebrow. Once we extract eye regions, we connect the center points of the two eyes and calculate the angle between them. Then we rotate the face to compensate for the angle so that the two eyes on a horizontal line. We tested 120 input images form 40 people, and achieved 91.7% success rate using eye size rules and face model. The main reasons of the 8.3% failure are due to components adjacent to eyes such as eyebrows. To detect facial components from the failed images, we are developing a mouth region processing module.

  • PDF

Development of a New Hibiscus Cultivar 'Daewangchun' with Vigorous Growth and Unique Red Eye through Interspecific Hybridization

  • Ha, Yoo-Mi;Lim, Ki-Byung;Shim, Kyung-Ku
    • Horticultural Science & Technology
    • /
    • v.33 no.3
    • /
    • pp.453-458
    • /
    • 2015
  • A new Hibiscus cultivar 'Daewangchun', having vigorous growth, uniform plant habit, upright, compact branches, and a long red eye was developed through interspecific crosses between H. syriacus 'Samchully' (♀) and H. sinosyriacus 'Seobong' (♂). The Hibiscus breeding program was initiated in 2005 and Hibiscus ${\times}$ 'Daewangchun' was preliminarily selected as '05-R-204' in 2 008 due to its vigorous growth and stable flower quality w ith rich pink flowers. The s elected line was further evaluated for different growth characteristics, leaf shape, leaf size, and flowering characteristics, as well as tested for distinctness, homogeneity, and stability during 2010-2012. The new cultivar 'Daewangchun' had violet pink flowers (RHS N80C) with a long red eye spot, medium size and fan petals. The size of flower was 12.0 cm and size of the red eye was 3.0 cm. Leaves were 8.7 cm long and 4.7 cm wide. After plant characteristic evaluation for 3 years (2010-2012), 05-R-204 was registered as cultivar 'Daewangchun' (4731, No. of plant variety protection rights) in 2013. This newly developed cultivar 'Daewangchun' has tall vigorous growth and unique flowers with a long red eye and can be used as specimen plants in landscaping.

Comparative Study on Growth Stage Aging Changes of The Right and Left Eye Size in Korean (성장기 연령 변화에 따른 좌우안 크기 변화 비교 연구)

  • Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.209-216
    • /
    • 1998
  • The purpose of this study was to compare the right and left eye size, distance between two eyes, interpupillary distance on growth stage aging changes in Korean. The author divided into 5 groups according to subject's age(group A : 7~12 years, group B : 13~15 years, group C : 16~18 years, group D : 19~24 years, group E : 25~30 years). The high values of inter outer canthal distance(T) and distance between two eyes(G) were 94.30 mm, 36.66 mm at group B respectively. The ratio of identical eye size was about 10.0% in A, B, C group but 22.7% in E group. P[T-(right eye size + left eye size) / 2] was wider than IPD. Data showed that the difference was 5.72 mm in group B and 1.13 mm in group E. The reason for this is that the pupils are displaced nasally from the center of the limbal ring. This has significant meaning in ophthalmic procedures.

  • PDF

Webcam-Based 2D Eye Gaze Estimation System By Means of Binary Deformable Eyeball Templates

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.575-580
    • /
    • 2010
  • Eye gaze as a form of input was primarily developed for users who are unable to use usual interaction devices such as keyboard and the mouse; however, with the increasing accuracy in eye gaze detection with decreasing cost of development, it tends to be a practical interaction method for able-bodied users in soon future as well. This paper explores a low-cost, robust, rotation and illumination independent eye gaze system for gaze enhanced user interfaces. We introduce two brand-new algorithms for fast and sub-pixel precise pupil center detection and 2D Eye Gaze estimation by means of deformable template matching methodology. In this paper, we propose a new algorithm based on the deformable angular integral search algorithm based on minimum intensity value to localize eyeball (iris outer boundary) in gray scale eye region images. Basically, it finds the center of the pupil in order to use it in our second proposed algorithm which is about 2D eye gaze tracking. First, we detect the eye regions by means of Intel OpenCV AdaBoost Haar cascade classifiers and assign the approximate size of eyeball depending on the eye region size. Secondly, using DAISMI (Deformable Angular Integral Search by Minimum Intensity) algorithm, pupil center is detected. Then, by using the percentage of black pixels over eyeball circle area, we convert the image into binary (Black and white color) for being used in the next part: DTBGE (Deformable Template based 2D Gaze Estimation) algorithm. Finally, using DTBGE algorithm, initial pupil center coordinates are assigned and DTBGE creates new pupil center coordinates and estimates the final gaze directions and eyeball size. We have performed extensive experiments and achieved very encouraging results. Finally, we discuss the effectiveness of the proposed method through several experimental results.

A Study on Lean-SMAIS Methodology for Field Work Improvement - By using ProEye Software - (현장작업 개선을 위한 Lean-SMAIS 방법론 연구 -프로아이(ProEye) 소프트웨어 활용 중심으로-)

  • Park, Chang-Do;Ree, Sang-Bok
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.2
    • /
    • pp.166-175
    • /
    • 2012
  • Enterprises are continuously trying management innovation activities for survival. Among representative management innovation activities in domestic manufacture enterprise, which are TPS, 6 sigma, Lean 6 sigma etc. Many enterprises through these reform activity have gotten good result. However, these techniques have merits and demerits according to circumstance of enterprise. Specially, there are a lot of difficulties in medium and small size enterprises. In this research, We introduce Lean-SMAIS Method for medium and small size enterprises that is consists of the merit of lean 6 sigma and software(which is called ProEye). We prove Lean-SMAIS method is useful by applying medium and small size enterprise A company.

TSV Fault Detection Technique using Eye Pattern Measurements Based on a Non-Contact Probing Method (Eye 패턴을 사용한 비접촉 형태의 TSV 고장 검출 기법)

  • Kim, Youngkyu;Han, Sang-Min;Ahn, Jin-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.592-597
    • /
    • 2015
  • 3D-IC is a novel semiconductor packaging technique stacking dies to improve the performance as well as the overall size. TSV is ideal for 3D-IC because it is convenient for stacking and excellent in electrical characteristics. However, due to high-density and micro-size of TSVs, they should be tested with a non-invasive manner. Thus, we introduce a TSV test method on test prober without a direct contact in this paper. A capacitive coupling effect between a probe tip and TSV is used to discriminate small TSV faults like voids and pin-holes. Through EM simulation, we can verify the size of eye-patterns with various frequencies is good for TSV test tools and non-contact test will be promising.

The Experimental Study of Safety and Efficacy in Using Bovis Calculus Pharmacopuncture Solution as Eye Drop (점안용 우황약침액의 안전성 및 유효성 평가)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.12 no.3
    • /
    • pp.61-72
    • /
    • 2009
  • Objectives : This experimental study was performed to investigate the safety and efficacy of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. To identify the use of it as eye drop, the eye irritation test of rabbits and the antibacterial test of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans were performed. Methods : 1. The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 2. After administering Bovis Calculus pharmacopuncture solution on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis, MIC(Minimum Inhibition Concentration) and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : 1. After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, it was found that none of nine rabbits have abnormal signs and weight changes. 2. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, no eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 3. There was no response to MIC on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) after Bovis Calculus pharmacopuncture solution was medicated. Conclusions : The present study suggests that Bovis Calculus pharmacopuncture solution is a nontoxic and non-irritant medicine, which does not cause eye irritation in rabbits, but dosen't have antibacterial effects on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

Development of Obstacle Database Management Module for Obstacle Estimation and Clustering: G-eye Management System (장애물 추정 및 클러스터링을 위한 장애물 데이터베이스 관리 모듈 개발: G-eye 관리 시스템)

  • Min, Seonghee;Oh, Yoosoo
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.344-351
    • /
    • 2017
  • In this paper, we propose the obstacle database management module for obstacle estimation and clustering. The proposed G-eye manager system can create customized walking route for blind people using the UI manager and verify the coordinates of the path. Especially, G-eye management system designed a regional information module. The regional information module can improve the loading speed of the obstacle data by classifying the local information by clustering the coordinates of the obstacle. In this paper, we evaluate the reliability of the walking route generated from the obstacle map. We obtain the coordinate value of the path avoiding the virtual obstacle from the proposed system and analyze the error rate of the path avoiding the obstacle according to the size of the obstacle. And we analyze the correlation between obstacle size and route by classifying virtual obstacles into sizes.

Testing of the Safety and the Effectiveness of Using Samjeong Pharmacopuncture Solution as Eye drops

  • Seo, Hyung-Sik;Lee, Dong-Jin
    • Journal of Pharmacopuncture
    • /
    • v.15 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • Objective: This experimental study was designed to investigate the safety and the effectiveness of Samjeong pharmacopuncture solution (SPS) manufactured by using a the lowtemperature extract on process. Methods: To identify the safety and the effectiveness of using SPS as eye drops, we performed applied eye irritation tests on rabbits and antibacterial tests for Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans. The eye irritation test was performed according to the toxicity testing regulation of the Korea Food & Drug Administration (2009. 8. 24, KFDA 2009-116). After SPS had been applied on the left eye of the rabbits, eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. After SPS had been dropped on bacterial species that cause keratitis, the minimum inhibition concentration and the size of the inhibition zone were measured. The anti-bacterial potency was also measured by taking the size of inhibition zone. Results: After SPS had been administered on the left eye of the rabbits, none of nine rabbits were found to show abnormal signs or weight changes. After SPS had been administered on the left eye of the rabbits, no eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. No specific response was detected in MIC for bacterial species Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans after SPS had been applied. Conclusions: This study suggests that SPS is a non-toxic and non-irritant medicine that does not cause any of eye irritation in rabbits, but it has no antibacterial effects on bacterial species that are well known to cause keratitis. These results suggest that more research is required on extracts from herbal medicines for treating keratitis.

Generation of Visual Field Considering 8 Meridians and Background Conditions of Visual Tasks (시각작업의 배경 조건과 8개 Meridian을 고려한 시각영역의 생성)

  • Kee, Do-Hyung;Kim, Hyung-Su;Jung, Eui-S.;Kang, Dong-Seok
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.3
    • /
    • pp.533-544
    • /
    • 1997
  • Among numerous factors that have an effect on visual field, the effects of background condition on the size of the visual field were investigated to obtain more practical visual field that can be readily applicable to industrial settings. A visual experiment was conducted, in which the subject was instructed to search a target with distinct orientations. Size contrast, meridian, nontarget density, and subject's gender showed a significant effect on the size of the visual field at $\alpha=0.01$. The size of the visual field was linearly proportional to size contrast, and inversely proportional to density. Female's visual fields were found to be significantly larger than male subjects', The size of the visual field on horizontal axis was larger than that on vertical axis, and the size of the head & eye field on right meridian was also larger than that on left meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. The regression equations to predict the visual fields on the given background condition were suggested. The visual fields suggested in this study would be valuable to the design of visual displays and the panel layout of various displays and controls.

  • PDF