• Title/Summary/Keyword: extremely low power

Search Result 233, Processing Time 0.025 seconds

A study on vulnerability analysis and incident response methodology based on the penetration test of the power plant's main control systems (발전소 주제어시스템 모의해킹을 통한 취약점 분석 및 침해사고 대응기법 연구)

  • Ko, Ho-Jun;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.295-310
    • /
    • 2014
  • DCS (Distributed Control System), the main control system of power plants, is an automated system for enhancing operational efficiency by monitoring, tuning and real-time operation. DCS is becoming more intelligent and open systems as Information technology are evolving. In addition, there are a large amount of investment to enable proactive facility management, maintenance and risk management through the predictive diagnostics. However, new upcoming weaponized malware, such as Stuxnet designed for disrupting industrial control system(ICS), become new threat to the main control system of the power plant. Even though these systems are not connected with any other outside network. The main control systems used in the power plant usually have been used for more than 10 years. Also, this system requires the extremely high availability (rapid recovery and low failure frequency). Therefore, installing updates including security patches is not easy. Even more, in some cases, installing security updates can break the warranty by the vendor's policy. If DCS is exposed a potential vulnerability, serious concerns are to be expected. In this paper, we conduct the penetration test by using NESSUS, a general-purpose vulnerability scanner under the simulated environment configured with the Ovation version 1.5. From this result, we suggest a log analysis method to detect the security infringement and react the incident effectively.

Monitoring of grout material injected under a reservoir using electrical and electromagnetic surveys (전기비저항 및 전자탐사를 이용한 저수지 하부에 주입된 그라우트 재료의 모니터링)

  • Suzuki, Koichi;Oyama, Takahiro;Kawashima, Fumiharu;Tsukada, Tomoyuki;Jyomori, Akira
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • In order to reduce leakage from a reservoir, a large amount of cement milk (grout) was injected from boreholes drilled around the shores of the reservoir, and monitored to establish the infiltration of cement milk into the bedrock under the reservoir. From laboratory tests using rock core samples, it was revealed that the resistivity of cement milk is much lower than that of the groundwater at this location. Therefore, it was expected that the resistivity of the zones filled with cement milk would be significantly reduced. Geophysical surveys are expected to be suitable methods to check the effectiveness of grouting in improving the water-retaining performance of a reservoir. DC electrical surveys (seven in total) and two Controlled Source Audio-frequency Magneto-Telluric (CSAMT) surveys were conducted along survey lines in the reservoir to monitor the infiltration of cement milk during the grouting. Extremely low resistivity zones ($10\;{\Omega}m$ or less) were observed in resistivity sections obtained by 2D inversion. The zones are inferred to be fractured zones filled with cement milk. In sections showing the rate of change of resistivity, three zones that showed significant change showed gradual expansion to deeper parts as the grouting progressed. These zones correspond to highly permeable zones detected by Lugeon tests at grout boreholes. We have confirmed that it is possible to measure the resistivity change by DC electrical and CSAMT surveys from the surface of the reservoir. It seems that such monitoring results could be reflected in future grouting plans.

The Effect of Electromagnetic Noise on the Wireless LAN Using Direct Sequence Spread Spectrum (DSSS 방식용 무선 LAN에 대한 전파 잡음의 영향)

  • Kim, Che-Young;Park, Jeung-Keun;Park, Seng-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.6
    • /
    • pp.630-639
    • /
    • 2008
  • In this paper, we investigate the cause of throughput degradation on the wireless local area network(WLAN) and the reason of interference level change attributed to the spanned frequency in the presence of electromagnetic interference. We also measured and quantified the electric field strength of interference which yields the abrupt change of the throughput. Two units of WLAN and one unit of AP(Access Point) are configured to maintain the radio link. As the sources of interference, both the co-channel and adjacent-channel interference are considered and the critical values of electric field are provided for each case. Our experimental observations show that the signal strength generated from these interference sources is at most less than 54 dBuV/m @3 m in order to coexist between WLANs and other low power radio devices without any noticeable throughput decreases. Based on our empirical results, as far as 802.11b WLAN is concerned, we believe that the current domestic limit of the signal strength for an extremely low power radio device, 30.9 dBuV/m @3 m, can be increased as much as 23.1 dB.

Numerical Analysis of Heat Transfer and Fuel Conversion for MCFC Preconverter (MCFC 프리컨버터 촉매의 열전도특성과 연료전환율 해석)

  • Byun, Do-Hyun;Sohn, Chang-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.425-430
    • /
    • 2012
  • In this study, a preconverter of an MCFC for an emergency electric power supplier is numerically simulated to increase the hydrogen production from natural gas (methane). A commercial code is used to simulate a porous catalyst with a user subroutine to model three dominant chemical reactions-steam reforming, water-gas shift, and direct steam reforming. To achieve a fuel conversion rate of 10% in the preconverter, the required external heat flux is supplied from the outer wall of the preconverter. The calculated results show that the temperature distribution and chemical reaction are extremely nonuniform near the wall of the preconverter. These phenomena can be explained by the low heat conductivity of the porous catalyst and the endothermic reforming reaction. The calculated results indicate that the use of a compact-size preconverter makes the chemical reaction more uniform and provides many advantages for catalyst maintenance.

Development of a Portable ELF Electric Field Meter (휴대용 극저주파 전장측정기 개발)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • This paper dealt with the developed portable electric field meter which consisted of planar-type sensor, analog amplifier with gain controller, A/D convertor, and display unit. The principle of the planar-type sensor for detecting time-varying electric field of extremely low frequency (ELF) bandwidth was described, and a calibration system using cylindrical guard electrodes and parallel-plate electrodes was proposed. From the calibration experiment, the frequency bandwidth and the sensitivity of the developed electric field meter was $17[Hz]{\sim}7[kHz]$, and 4.45[mV/V/m], respectively. Also it can measure the electric field strength up to 10[kV/m], and the measured result was displayed on the liquid crystal display in digit. The electric field meter can be widely applied to measure electric field strength radiated from power lines, computers, and home appliances such as hair dryer, heater, etc.

  • PDF

Fabrication of Graphene Field-effect Transistors with Uniform Dirac Voltage Close to Zero (균일하고 0 V에 가까운 Dirac 전압을 갖는 그래핀 전계효과 트랜지스터 제작 공정)

  • Park, Honghwi;Choi, Muhan;Park, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.204-208
    • /
    • 2018
  • Monolayer graphene grown via chemical vapor deposition (CVD) is recognized as a promising material for sensor applications owing to its extremely large surface-to-volume ratio and outstanding electrical properties, as well as the fact that it can be easily transferred onto arbitrary substrates on a large-scale. However, the Dirac voltage of CVD-graphene devices fabricated with transferred graphene layers typically exhibit positive shifts arising from transfer and photolithography residues on the graphene surface. Furthermore, the Dirac voltage is dependent on the channel lengths because of the effect of metal-graphene contacts. Thus, large and nonuniform Dirac voltage of the transferred graphene is a critical issue in the fabrication of graphene-based sensor devices. In this work, we propose a fabrication process for graphene field-effect transistors with Dirac voltages close to zero. A vacuum annealing process at $300^{\circ}C$ was performed to eliminate the positive shift and channel-length-dependence of the Dirac voltage. In addition, the annealing process improved the carrier mobility of electrons and holes significantly by removing the residues on the graphene layer and reducing the effect of metal-graphene contacts. Uniform and close to zero Dirac voltage is crucial for the uniformity and low-power/voltage operation for sensor applications. Thus, the current study is expected to contribute significantly to the development of graphene-based practical sensor devices.

Estimation of Probability Density Function of Tidal Elevation Data using the Double Truncation Method (이중 절단 기법을 이용한 조위자료의 확률밀도함수 추정)

  • Jeong, Shin-Taek;Cho, Hong-Yeon;Kim, Jeong-Dae;Hui, Ko-Dong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.3
    • /
    • pp.247-254
    • /
    • 2008
  • The double-peak normal distribution function (DPDF) suggested by Cho et al.(2004) has the problems that the extremely high and low tidal elevations are frequently generated in the Monte-Carlo simulation processes because the upper and lower limits of the DPDF are unbounded in spite of the excellent goodness-offit results. In this study, the modified DPDF is suggested by introducing the upper and lower value parameters and re-scale parameters in order to remove these problems. These new parameters of the DPDF are optimally estimated by the non-linear optimization problem solver using the Levenberg-Marquardt scheme. This modified DPDF can remove completely the unrealistically generated tidal levations and give a slightly better fit than the existing DRDF. Based on the DPDF's characteristic power, the over- and under estimation problems of the design factors are also automatically intercepted, too.

A New Multi-Beam MVDR Technique for Removing Interference Signals in Array Antenna Based GPS Receivers (GPS 수신기에서 간섭신호 제거를 위한 배열 안테나 기반 다중 빔 MVDR 기법)

  • Jeong, Eui-Rim;Won, Hyun-Hee;Yang, Gi-Jung;Ahn, Byoung-Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.491-498
    • /
    • 2017
  • GPS (global positioning system) is a popular system that provides location information by measuring arrival time difference at the receiver between several GPS satellite signals. GPS is widely used in commercial area as well as military systems. Reliable GPS signal reception is more important in the military applications such as guided missiles. However, since the carrier frequencies of the GPS signals are well known and the received power is extremely low, the GPS systems are vulnerable to intentional jamming attacks. To remove jammers while maintaining GPS signals at the received signals, a popular technique is an adaptive beam steering method based on array antenna. Among adaptive beam steering techniques, this paper considers MVDR (minimum variance distortionless response) algorithm, and proposes a new adaptive technique that preserves the received signals at desired directions, but removes the unknown jamming signals adaptively. The performance of the proposed method is verified through computer simulation.

Separation and Recovery of F-gases (불화 온실 가스 저감 및 분리회수 기술의 연구개발 동향)

  • Nam, Seung-Eun;Park, Ahrumi;Park, You-In
    • Membrane Journal
    • /
    • v.23 no.3
    • /
    • pp.189-203
    • /
    • 2013
  • F-gases, gases containing fluorine such as perfluorocarbons (PFCs), sulfurhexafluoride ($SF_6$), nitrogen trifluoride ($NF_3$) are known to have green house effects. Although the net emission rates of gases containing fluorine are much lower than those of $CO_2$, their contribution to global warming cannot be ignored because of their extremely high global warming potential (GWP). F-gases mainly have been used for a variaty of applications in the semiconductor/LCD processes and in the electric power distribution industry of the national key industry. One of practical solutions of controlling the emission rates of F-gases is to reuse by separation and recovery of F-gases of low concentration from the gases mixtures with nitrogen or air. This work investigates some methods for F-gases recovery and separation around the membrane-based process.

A Constant-gm Global Rail-to-Rail Operational Amplifier with Linear Relationship of Currents (전영역에서 선형 전류 관계를 갖는 일정 트랜스컨덕턴스 연산 증폭기의 설계)

  • Jang, Il-Gwon;Gwak, Gye-Dal;Park, Jang-U
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.2
    • /
    • pp.29-36
    • /
    • 2000
  • The principle and design of two-stage CMOS operational amplifier with rail-to-rail input and class-AB output stage is presented. The rail-to-rail input stage shows almost constant transconductance independent of the common mode input voltage range in global transistor operation region. This new technique does not make use of accurate current-voltage relationship of MOS transistors. Hence it was achieved by using simple linear relationship of currents. The simulated transconductance variation using SPICE is less the 4.3%. The proposed global two-stage opamp can operate both in strong inversion and in weak inversion. Class AB output stage proposed also has a full output voltage swing and a well-defined quiescent current that does not depend on power supply voltage. Since feedback class- AB control is used, it is expected that this output stage can be operating in extremely low voltage. The variation of DC-gain and unity-gain frequency is each 4.2% and 12%, respectively.

  • PDF