• 제목/요약/키워드: extremely low frequency-magnetic field (ELF-MF)

검색결과 15건 처리시간 0.024초

Effect of a 60Hz electromagnetic field on the frequency of bleomycin-induced HPRT gene mutation and 1,2,4-benzenetriol-induced sister chromatid exchanges in CHO cell

  • Chung, Hai-Won;Kang, Su-Jin;Lee, Young-Joon;Kim, Su-Young
    • Journal of Radiation Protection and Research
    • /
    • 제27권2호
    • /
    • pp.81-87
    • /
    • 2002
  • The interaction of low density extremely low frequency magnetic field (ELF MF) in the frequency of hypoxanthine-guanine phosphoribosyltransferase (HPRT) mutation induced by bleomycin and on the frequency of sister chromatid exchanges (SCEs) induced by 1,2,4-benzenetriol(BT) was demonstrated. CHO cells pretreated with bleomycin or 1,2,4-benzenetriol were exposed for 24hrs to a sinusoidal 0.8mT magnetic field at 60Hz. Frequency of HPRT mutation and SCEs were determined. ELF MF exposure led to a two-fold increase of the frequency of HPRT mutation induced by bleomycin. No increase of mutation frequency was observed by ELF MF alone ELF MF also increased the frequency of SCEs induced by BT while no Increase of SCE frequencies were observed by ELF MF alone. These results suggest that low density ELF MF field would art as an enhancer rather than as an initiator of mutagenic effects in CHO cell.

THE EFFECT OF EXTREMELY LOW FREQUENCY MAGNETIC FIELD (ELF-MF) ON THE FREQUENCY OF MICRONUCLEI IN HUMAN LYMPHOCYTES INDUCED BY BENZO(A)PYRENE

  • Cho, Yoon-Hee;Kim, Su-Young;Chung, Hai-Won
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2001년도 International Symposium on Dietary and Medicinal Antimutgens and Anticarcinogens
    • /
    • pp.178-178
    • /
    • 2001
  • The interaction of extremely low frequency magnetic field (ELF-MF) on the frequency of micronuclei (MN) induced by benzo(a)pyrene (BP) in human lymphocytes was examined. A 60 Hz ELF-MF of 0.8 mT field strength was applied for 24 hours either alone or with the tumour initiator, BP. The frequency of MN induced by BP increased in a dose-dependent manner.(omitted)

  • PDF

직업성 극저주파 자기장 노출평가와 노출 기준에 대한 쟁점 고찰 (Brief Review on Exposure Characteristics, Monitoring Instruments and Threshold Limit Values for Extremely Low Frequency-Magnetic Field (ELF-MF))

  • 박동욱;이승희;조경이
    • 한국산업보건학회지
    • /
    • 제32권4호
    • /
    • pp.381-392
    • /
    • 2022
  • Objectives: Objective of this study is to review briefly exposure characteristics, monitoring instruments and threshold limit values for extremely low frequency-magnetic field (ELF-MF) methods. This study was undertaken through brief literature review. We performed a literature search in PubMed to identify ELF-MF studies conducted in workplaces. Initial search keywords such as 'extremely low frequency-magnetic field (ELF-MF)' and 'electromagnetic fields (EMF)' combined or singly. We limited our review to occupational rather than general nonworkplace environmental exposures. Methods: The contents we reviewed: key industry and occupations generating ELF-MF, several direct-reading instruments monitoring ELF-MF and threshold limit values (TLV) preventing health effects may be caused by the exposure to ELF-MF. Results: The industries related to the generation and supply of electricity, electrolytic installations, welding, and induction heating and more were regarded as high ELF-MF exposure industries. All jobs handling or employed performed in power cable lines, electrical wiring, and electrical equipment are found to be exposed to ELF-MF. Threshold or ceiling limit, 1,000 µT, is established to prevent acute effects of exposure to low-frequency EMFs on the nervous system: the direct stimulation of nerve and muscle tissues and the induction of retinal phosphenes. The International Agency for Research on Cancer (IARC) has classified ELF-MF as possibly carcinogenic to humans chiefly based on epidemiological studies on childhood leukemia. However, a causal relationship between magnetic fields and several types of cancer including childhood leukemia has not been established nor has any other long-term effects. Risk management using precautionary measures, has been initiated by the US and EU to prevent chronic health effects related to ELF-MF exposure in workplaces. Conclusion: This study recommends the implementation of various measures such as theestablishment of occupational exposure limit values for ELF-MF and precautionary principle to prevent potential chronic occupational health effects may be caused by ELF-MF in Korea.

Extremely Low Frequency Magnetic Field Modulates the Level of Neurotransmitters

  • Chung, Yoon Hee;Lee, Young Joo;Lee, Ho Sung;Chung, Su Jin;Lim, Cheol Hee;Oh, Keon Woong;Sohn, Uy Dong;Park, Eon Sub;Jeong, Ji Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제19권1호
    • /
    • pp.15-20
    • /
    • 2015
  • This study was aimed to observe that extremely low frequency magnetic field (ELF-MF) may be relevant to changes of major neurotransmitters in rat brain. After the exposure to ELF-MF (60 Hz, 2.0 mT) for 2 or 5 days, we measured the levels of biogenic amines and their metabolites, amino acid neurotransmitters and nitric oxide (NO) in the cortex, striatum, thalamus, cerebellum and hippocampus. The exposure of ELF-MF for 2 or 5 days produced significant differences in norepinephrine and vanillyl mandelic acid in the striatum, thalamus, cerebellum and hippocampus. Significant increases in the levels of serotonin and 5-hydroxyindoleacetic acid were also observed in the striatum, thalamus or hippocampus. ELF-MF significantly increased the concentration of dopamine in the thalamus. ELF-MF tended to increase the levels of amino acid neurotransmitters such as glutamine, glycine and ${\gamma}$-aminobutyric acid in the striatum and thalamus, whereas it decreased the levels in the cortex, cerebellum and hippocampus. ELF-MF significantly increased NO concentration in the striatum, thalamus and hippocampus. The present study has demonstrated that exposure to ELF-MFs may evoke the changes in the levels of biogenic amines, amino acid and NO in the brain although the extent and property vary with the brain areas. However, the mechanisms remain further to be characterized.

휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰 (Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans)

  • 박동욱;이성진;김소연;배서연;최상준;김원;민승현;박지훈;안종주
    • 한국환경보건학회지
    • /
    • 제44권5호
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Influence of Exposure to Extremely Low Frequency Magnetic Field on Neuroendocrine Cells and Hormones in Stomach of Rats

  • Hong, Min-Eui;Yoon, Kyu-Hyun;Jung, Yoon-Yang;Lee, Tae-Jin;Park, Eon-Sub;Sohn, Uy-Dong;Jeong, Ji-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제15권3호
    • /
    • pp.137-142
    • /
    • 2011
  • Extremely low frequency magnetic fields (ELF-MF) have the ability to produce a variety of behavioral and physiological changes in animals. The stomach, as the most sensitive part of the neuroendocrine organ of the gastrointestinal tract, is crucial for the initiation of a full stress response against all harmful stress. Thus, the purpose of this study was to examine whether ELF-MF stimuli induce changes in the activity of neuroendocrine cells, considering their involvement in endocrine or paracrine effect on surrounding cells. The exposure to ELF-MF (durations of 24 h and 1 or 2 weeks, 60 Hz frequency, 0.1 mT intensity) altered the distribution and occurrence of gastrin, ghrelin and somatostatinpositive endocrine cells in the stomach of rats. The change, however, in the secretion of those hormones into blood from endocrine cells did not appear significantly with ELF-MF exposure. Comparing with sham control, ELF-MF exposure for 1 and 2 week induced an increase in $BaSO_4$ suspension propelling ratio of gastrointestinal tract, indicating that ELF-MF affects gastrointestinal motility. Our study revealed that ELF-MF exposure might influence the activity of endocrine cells, an important element of the intrinsic regulatory system in the digestive tract. The pathophysiological character of these changes and the mechanism responsible for neuroendocrine cell are still unclear and require further studies.

The influence of extremely low frequency magnetic field on cardiovascular response

  • Kim, Jeong-Soo;Jeong, Ji-Hoon;Sung, Ji-Hyun;Bae, Ki-Lyong;Kum, Chan;Kang, Hee-Yun;Sohn, Uy-Dong
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.274.1-274.1
    • /
    • 2002
  • There have been some reports showing that cardiovascular response is affected by exposure to extremely low frequency magnetic field (ELF-MF). In this experiment. we intended to observe if ELF-MF affects the basal level of cardiovascular response and effect of drugs acting on sympathetic nervous system. Rats exposed to MF (60 Hz. 20 G) for 1 or 5 days and sham were anesthetized with pentobarbital-Na. Carotid artery and jugular vein were intubated to measure blood pressure (BP) and inject drug respectively. (omitted)

  • PDF

The effects of extremely low frequency magnetic field on bicuculline, picrotoxin, NMDA-induced seizures in mice

  • Sung, Ji-Hyun;Jeong, Ji-Hoon;Kim, Jeong-Soo;Kum, Chan;Park, Sun-Young;Sohn, Uy-Dong
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.274.2-274.2
    • /
    • 2002
  • Some experiments have been reported that magnetic fields can cause the change of numerous neurotransmitters including excitatory and inhibitory transmitters, which are involved in seizures. In this study we aimed to examine the effect of extremely low frequency magnetic field (ELF-MF) on the sensitivity of seizure response to bicuculline, picrotoxin and NMDA in mice. Mouse were exposed to sham or 20 G ELF-MF for 24 hours and then convulsants were administered i.p. at various doses. (omitted)

  • PDF

고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구 (Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines)

  • 박성애;정준식;최태봉;정민주;김부경;이종천
    • 환경영향평가
    • /
    • 제27권6호
    • /
    • pp.658-673
    • /
    • 2018
  • 극저주파자기장 노출에 대한 사회적 갈등은 계속되는 전력 수요의 증가와 고압송전선로의 증설로 심화될 것으로 예상되고 있다. 그러나 현행 환경영향평가법상 이에 대한 구체적 작성규정이나 지침이 마련되어 있지 않은 실정이다. 따라서 본 연구는 극저주파자기장의 주요 발생원이라 할 수 있는 고압 가공 송전선로를 대상으로 환경영향평가 사례분석, 현장측정 및 전문가 자문을 통하여 환경영향평가 방법에 대한 표준화 연구를 수행하였다. 극저주파자기장의 환경영향평가의 문제점과 개선해야 할 사항을 도출하고, 이를 반영하여 환경영향평가 방법을 제안하였다. 주요내용으로는 환경영향평가의 현황조사-영향예측-저감방안마련-사후환경영향평가계획의 각 단계에서 거리와 전류량에 영향을 받는 극저주파자기장의 물리적 특성을 고려한 계획수립 및 결과분석 과정을 제안하였다. 본 연구 내용을 기반으로 환경영향평가 실무에 적용시킬 수 있는 '전력선에 대한 극저주파자기장 공정시험방법(안)'과 '전력선에서의 극저주파자기장 측정기록표'를 마련하였고, 29개 항목의 극저주파자기장 점검표를 작성하였다. 이러한 연구결과는 극저주파자기장의 장기적 노출에 대한 인체유해성이 불명확한 현 시점에서 송전선로 피해와 갈등을 최소화하고 합리적 방안을 도출하는 환경영향평가에 활용될 수 있을 것이다.