• 제목/요약/키워드: external validity

검색결과 355건 처리시간 0.029초

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

Comparative Systematic Review of Korea Domestic and International Studies on Sensory Integration Therapy in Patients with Autism Spectrum Disorder

  • Cha, Sumin;Park, Sookyoung;Choi, Jeonghyun;Park, Juhyung;Jin, Yunho;Hong, Yonggeun
    • International Journal of Contents
    • /
    • 제15권3호
    • /
    • pp.13-20
    • /
    • 2019
  • This systematic review compared Korean and international researches on sensory integration therapy in patients with autism spectrum disorder (ASD). We targeted studies on sensory integration therapy for patients with ASD published from January 2000 through July 2016. Specifically, we analyzed the papers that used the phrase 'sensory integration, autism' as keywords. There were fewer Korean studies of sensory integration therapy, and the diversity of research topics were limited, focusing mainly on case studies. There was no difference between the internal/external validity of Korean and those of international studies targeting the clinical environment and patients. Further study of a variety of aspects of sensory integration therapy is needed to gain high internal/external validity.

The Validity and Reliability of the Second Korean Working Conditions Survey

  • Kim, Young Sun;Rhee, Kyung Yong;Oh, Min Jung;Park, Jungsun
    • Safety and Health at Work
    • /
    • 제4권2호
    • /
    • pp.111-116
    • /
    • 2013
  • Background: The aim of this study was to evaluate the quality of the Second Korean Working Conditions Survey (KWCS), focusing on its validity and reliability. Methods: The external validity was evaluated by the assessment of sampling procedures and the response rate, in order to investigate the representativeness of the sample. The content validity was evaluated by the assessment of the development of the questionnaire, and the consistency of questions for the selected construct. The test-retest method was used to evaluate the reliability by means of a phone call survey of 30% of the respondents, who were randomly selected. The respondents' satisfaction regarding the survey procedures and interview time were analyzed to evaluate the quality of survey data. Results: The external validity was assured by an acceptable sampling procedure, rigid multi-stage stratified cluster random sampling. The content validity was also guaranteed by a reasonable procedure for the development of the questionnaire with a pretest. The internal consistency of the questions for work autonomy was maintained, with 0.738 of Cronbach's alpha. The response rate of 36% was lower than that of the European Working Conditions Survey (EWCS), with a contact rate of 66%, compared to 76% for the EWCS. The matching rates of the five retested questions were more than 98% reliable. Conclusion: The quality of the second KWCS was assured by the high external and content validity and reliability. The rigid sampling procedure and development of the questionnaire contributed to quality assurance. The high level of reliability may be guaranteed by the sophisticated field survey procedures and the development of a technical manual for interviewers. The technical strategies for a high response rate should be developed for future surveys.

클러스터 평가 외부기준 척도 $F_n$-Measure ($F_n$-Measure : An External Cluster Evaluation Measure)

  • 김경택
    • 산업경영시스템학회지
    • /
    • 제35권4호
    • /
    • pp.244-248
    • /
    • 2012
  • F-Measure is one of the external measures for evaluating the validity of clustering results. Though it has clear advantages over other widely used external measures such as Purity and Entropy, F-Measure has inherently been less sensitive than other validity measures. This insensitivity owes to the definition of F-Measure that counts only most influential portions. In this research, we present $F_n$-Measure, an external cluster evaluation measure based on F-Measure. $F_n$-Measure is so sensitive that it can detect their difference in the cases that F-Measure cannot detect the difference in clustering results. We compare $F_n$-Measure to F-Measure for a few clustering results and show which measure draws better result based upon homogeneity and completeness.

A Study on Controlling the External Effect in Student Evaluation of Teaching

  • Lee S. W.;Lee K. H.
    • Communications for Statistical Applications and Methods
    • /
    • 제12권3호
    • /
    • pp.589-601
    • /
    • 2005
  • Student evaluation of university teaching is a common tool for measuring the educational contribution of a professor and improving the quality of classes. There, however, exist external factors in the beyond of control of a instructor, which affect the result of Student's rating to prevent practical use of evaluation for administrative purpose. This paper investigates the factors that spoil the validity and the reliability of student evaluation and proposes a method to control the effect by the statistical analysis of evaluation data of Jeonju University for two years.

고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성 (Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement)

  • 김용욱
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

한국판 청소년용 음식중독도구의 타당도와 신뢰도 (Validity and Reliability of a Korean Version of Yale Food Addiction Scale for Children (YFAS-C))

  • 김정호;송지현;김란;장미영;홍현주;김현지;신성희
    • 대한간호학회지
    • /
    • 제49권1호
    • /
    • pp.59-68
    • /
    • 2019
  • Purpose: This study evaluated the psychometric properties of the Korean version of Yale Food Addiction Scale for Children (YFAS-C). Methods: Participants were 419 young adolescent students (11~15 years old). The content validity of the expert group was calculated as the content validity index (CVI) after the translation and reverse translation process of the 25 items of the YFAS-C. The multitrait-multimethod matrix (MTMM) method was used to verify the construct validity; the generalized linear model (GLM) was used to evaluate the concurrent and incremental validity. Reliability was calculated as Kuder-Richardson-20 (KR-20) and Spearman-Brown coefficients. Results: The CVI of the 25 items was greater than the item-level CVI .80 and the scale-level CVI .90. The Korean version of YFAS-C had verified convergent validity in emotional eating and external eating and discriminant validity in restrained eating. In addition, it had verified concurrent validity in emotional eating and external eating. Finally the incremental validity of the Korean version of YFAS-C was statistically significant on BMI. Reliability was KR-20 ${\alpha}=.69$ and the Spearman-Brown coefficient was .64. Conclusion: The Korean version of YFAS-C is a valid and reliable scale for measuring the severity of food addiction; it can be a useful scale for preventing obesity by predicting food addiction early.

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.

초등학교 과학과 5, 6학년 서술형 평가문항의 행동영역 내용타당도 및 이에 영향을 미치는 요인 분석 (An Analysis of Content Validity of Behavioral Domain of Descriptive Tests and Factors that Affect Content Validity: Focus on the Fifth and Sixth Grade Science)

  • 최정인;백성혜
    • 한국과학교육학회지
    • /
    • 제36권1호
    • /
    • pp.87-101
    • /
    • 2016
  • 본 연구의 목적은 초등학교에서 개발 시행된 서술형 평가 문항의 내용타당도를 분석하는데 있으며, 이 평가 문항들의 개선을 위한 기초자료를 제시하는데 연구의 의의가 있다. 이를 위하여 여러 초등학교의 서술형 평가문항을 수집하고, 이원분류표의 평가목표와 문항의 평가목표가 요구하는 행동소를 비율차 검정하였다. 분석의 결과 교사가 제작한 서술형 평가문항은 '지식', '이해'를 주로 측정하고 있으며, 행동영역의 내용타당도가 낮음을 확인하였다. 내용타당도가 낮은 결과를 설명하기 위해 9명의 초등 교사를 대상으로 면담을 실시하였다. 면담의 결과 초등학교 과학과 서술형 평가문항의 내용타당도 확보를 저해하는 요인으로 교사내적요인과 교사외적요인을 추출하였다. 교사내적요인에는 바르지 않은 이원분류표의 작성법, 초등학생의 발달 단계 고려, 난이도, 채점의 용이성, 경로의존성 등이 포함되었다. 그리고 교사외적으로는 교육과정 및 학부모 그리고 행정적 요소 등이었다. 이상의 결과를 바탕으로 과학교사의 서술형 평가전문성을 위한 요인들을 제언하였다.

간호사가 지각하는 직장 내 괴롭힘 측정도구 개발 (Development and Validity of Workplace Bullying in Nursing-Type Inventory (WPBN-TI))

  • 이윤주;이미형
    • 대한간호학회지
    • /
    • 제44권2호
    • /
    • pp.209-218
    • /
    • 2014
  • Purpose: The purpose of this study was to develop an instrument to assess bullying of nurses, and test the validity and reliability of the instrument. Methods: The initial thirty items of WPBN-TI were identified through a review of the literature on types bullying related to nursing and in-depth interviews with 14 nurses who experienced bullying at work. Sixteen items were developed through 2 content validity tests by 9 experts and 10 nurses. The final WPBN-TI instrument was evaluated by 458 nurses from five general hospitals in the Incheon metropolitan area. SPSS 18.0 program was used to assess the instrument based on internal consistency reliability, construct validity, and criterion validity. Results: WPBN-TI consisted of 16 items with three distinct factors (verbal and nonverbal bullying, work-related bullying, and external threats), which explained 60.3% of the total variance. The convergent validity and determinant validity for WPBN-TI were 100.0%, 89.7%, respectively. Known-groups validity of WPBN-TI was proven through the mean difference between subjective perception of bullying. The satisfied criterion validity for WPBN-TI was more than .70. The reliability of WPBN-TI was Cronbach's ${\alpha}$ of .91. Conclusions: WPBN-TI with high validity and reliability is suitable to determine types of bullying in nursing workplace.