• Title/Summary/Keyword: external rotation

Search Result 555, Processing Time 0.022 seconds

Factor Structure of a Korean-Language Version of the Patient Satisfaction with Procedural Aspects of Physical Therapy Instrument

  • Lee, Hae-Jung;Adams, Roger;Oh, Tae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The aim of the study was to survey satisfaction with physical therapy. Methods: After the physical therapy consultation, patients filled in a Korean-language version of the 20-tiem version of the MedRisk Instrument developed for measuring Patient Satisfaction with physical therapy. Items are scored on a five-point Likert scale ranging from strongly disagree to strongly agree. The last two items are general satisfaction and future return to the clinic. Age and gender information was also collected anonymously. Exploratory factor analysis based on principal components analysis with varimax rotation was performed on the first 18 items of the MedRisk Instrument using SPSS v.20. Results: Four factors emerged with eigenvalues greater than 1, and these cumulatively explained 55% of the total variance in item scores. The factors were labelled: Internal, External Positives, External Negatives, and Clinic Presentation. Correlations of the factor scores with the two global items ranged from 0.29 to 0.70 (both p<0.001). Gender differences were only found on the last factor, with male Korean patients rating Clinic Presentation significantly higher than females (p=0.001). Conclusion: Using factor analysis, the proposed factor structure was revealed using the positive and negative components of the external aspects of the physical therapy and by identifying a clinic presentation which contributes to patients' satisfaction. The largest proportion of the variance in Patient Satisfaction was related to clinicians' attention and behaviour. The results of the analysis provide guidelines as to the dimensions of professional physical therapy care and the implications for service delivery and patient experience.

Experimental Simulation of Local External Forcing of the Contained Rotating Flow (회전반 유체실험에서 국지적 외력의 실험적 모의)

  • Yi, Chang-Won;Na, Jung-Yul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.2
    • /
    • pp.77-85
    • /
    • 2000
  • Simulation of local external forcing and its response in the rotation table experiment has been investigated. Spatially-uniform external forcings have been applied in many experimental studies, however, based on the fact that the north-south distribution of the wind-stress curl and the existence of local maximum of the sea surface heat loss in the northern part of the East Sea, new method of combined effects of local forcings has been employed in separate experiments. Carefully designed local source or sink at the bottom of the cylindrical container can produce horizontal pressure gradient within the Ekman layer, and consequently the interior also attains the same pressure gradient that produces geostrophic interior circulation. In order to keep free surface during the local-surface cooling, a side-wall cooling method is suggested. For the various type of local forcing including the effects local cooling and the periodic change of local wind-stress curl, western-boundary flow in terms of its strength, position of separation from the boundary have been observed.

  • PDF

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

1.55 μm continuous tuning external cavity laser (1.55 μm 연속 가변 외부 공진기형 레이저)

  • 김강호;권오기;심은덕;이동훈;김종회;김현수;오광룡;김동유
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.321-326
    • /
    • 2003
  • We constructed grating- tuned external cavity semiconductor lasers using Littman and Littrow configuration, for which the wavelengths are tuned by rotation of the grating. This wavelength tunable semiconductor laser is one of the main devices of WDM optical communication. In Littman configuration, the wavelength range of about 60 nm (The C- and L-band range of 1,530~1,590 nm) was obtained by changing the incidence angle of the grating about $\pm$1$^{\circ}$ from the incidence angle of 70$^{\circ}$. In the 40 nm tuning range, the output power variation was less than 1.25 ㏈ and the side mode suppression ratio(SMSR) was 32 ㏈. In Littrow configuration (The incidence angle and the first order diffraction angle is the same, i.e. $\alpha$=$\delta$), the wavelength tuning range was about 80 nm for the same conditions used in Littman configuration except the incidence angle ($\alpha$=49$^{\circ}$). In 60 nm tuning range, the output power variation was less than 1.5 ㏈ and SMSR was 35 ㏈.

Effect of PNF Leg Flexion Pattern on Muscle Activity of Ipsilateral Trunk and Leg with and without Abdominal Drawing-in Maneuver (PNF 다리 굽힘 패턴 시 복부 드로잉-인 기법 동시적용이 동측 몸통과 다리의 근활성도에 미치는 효과)

  • Ahn, Su-Hong;Lee, Su-Kyong;Jo, Hyun-Dai
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the effect of the simultaneous abdominal drawing-in maneuver (ADIM) on the muscle activity of the ipsilateral trunk and leg during proprioceptive neuromuscular facilitation (PNF) leg flexion, adduction, and external rotation with knee flexion (D1) patterns. Methods: The participants were 20 healthy adult males and females (18 males and 2 females). The maneuvers were performed by a physical therapist who fully understands the PNF leg patterns (D1) and their application in clinical practice. The participants were trained and allowed to practice for 15 minutes prior to applying ADIM, to ensure adequate learning as evidenced by the pressure biofeedback unit. In this study, we measured the muscle activity of the trunk and leg when the PNF leg pattern (D1) was performed by the physical therapist either sustaining or releasing the ADIM. Muscle activity was measured on the right transverse abdominis muscle (TRA), the external abdominal oblique muscle (EO), the internal abdominal oblique muscle (IO), the erector spinae muscle (ES), the vastus medialis oblique muscle (VMO), the vastus lateralis oblique muscle (VLO), and the tibialis anterior muscle (TA) and compared using the mean values from averaging three repeated measurements. Results: The muscle activity of the transversus abdominis, the external abdominal oblique, the internal abdominal oblique, the vastus medialis oblique, and the vastus lateralis oblique was significantly greater (p < 0.05), and the muscle activity of the erector spinae was significantly less (p < 0.05) during PNF leg pattern (D1) when the ADIM contraction was sustained compared to when it was not. Conclusion: These results suggest that sustaining ADIM during PNF leg pattern (D1) training increases the trunk and leg muscle activity, resulting in more effective training.

Current Concepts in Arthroscopic Treatment of Anterior Shoulder Instability (견관절 전방 불안정에 대한 관절경적 최신 치료 경향)

  • Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.13-27
    • /
    • 2003
  • In the past, the report of shoulder instability undergoing open shoulder stabilization had satisfactory outcomes of greater than 90%. However, the functional loss of open procedure is severe in abduction and external rotation especially. Current arthroscopic techniques for shoulder instability result in success rate equal to open surgical procedure when the labrum is properly fixed to the glenoid rim using suture anchors, the capsule is tightened, and associated bony and soft tissue pathology is addressed. The arthroscopic surgery facilitates the view within shoulder joint for more accurate diagnosis, reduces operating time, minimises postoperative pain, reduces operative morbidity, improves shoulder function, and provides the possibility to perform other procedure simultaneously. However, to accomplish a successful arthroscopic stabilization procedure and to prevent complications, numerous advanced arthroscopic skill must be mastered. Although the arthroscope provides means to visualize new lesions, the pathomechanism and biomechanical explanation is not clear yet. Further studies are necessary to develop for shoulder reconstruction.

  • PDF

A Study of the Obstacle Avoidance for a Quadruped Walking Robot Using Genetic and Fuzzy Algorithm

  • Lee, Bo-Hee;Kong, Jung-Shik;Kim, Jin-Geol
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.228-231
    • /
    • 2003
  • This paper presents the leg trajectory generation for the quadruped robot with genetic-fuzzy algorithm. To have the nobility even at uneven terrain, a robot is able to recognize obstacles, and generates moving path of body that can avoid obstacles. This robot should have its own avoidance algorithm against obstacles, forwarding to target without collision. During walking period, n robot recognizes obstacle from external environment with a PSD and some interface, and this obstacle information is converted into proper the body rotation angle by fuzzy inference engine. After this process, we can infer the walking direction and walking distance of body, and finally can generate the optimal Beg trajectory using genetic algorithm. All these methods are verified with PC simulation program, and implemented to SERO-V robot.

  • PDF

Kinematic Characteristics during of Gait in Parkinson's Disease Patients (파킨슨 질환 환자의 보행시 운동형상학 특성)

  • You, Jae-Eung;An, Chang-Sik
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.453-458
    • /
    • 2001
  • The aim of this study is to present the basic reference data of age and specific gait parameters for Parkinson's Disease Patients. The basic gait parameters were extracted from 5 patients, 5 men and 65 years of age using VICON 512 Motion Analyzer. The temporal gait parameters and kinematic parameters is data of Parkinson's Disease Patients. The results were as follows; 1. The cadence, velocity, stride length decreased and single limb support period, double limb support period increased than normal adult in the temporal parameters. 2. The mean angles of joint pelvic tilt and hip, knee, ankle joint decreased than normal adult at kinematic characteristics on sagittal plane. 3. The mean angles of joint pelvic tilt and hip, knee joint has no difference than normal adult at kinematic characteristics on coronal plane. 4. The mean angles of joint pelvic tilt, hip joint no difference and internal, external rotation in ankle joint significantly decreased than normal adult at kinematic characteristics on transverse plane.

  • PDF

What Should We Treat For Recurrent Dislocation? (재발성 탈구에서 무엇을 치료할 것인가?)

  • Tae Suk-Kee
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.1
    • /
    • pp.1-4
    • /
    • 2004
  • As the multidirection and posterior instabilities of the shoulder are not only uncommon but responds well to conservative treatment, the shoulder instabilities which requires surgical treatment are traumatic anterior type in most cases, Although various surgical procedures had been used in the past, Bankart procedure is the standard surgical method as a primary procedure in traumatic anterior instability, Nevertheless there has been changes in the techniques of Bankart procedure in order to minimize decrease of external rotation and effectively address capsular laxilty, Capsular shift might be needed if there remains excessive capsular laxity of the inferior capsule after repair of the Bankart lesion, Large bony Bankart lesion should be fixed if possible and severe glenoid rim erosion requires extracapsular bone block after repair of the capsule. Although a few surgical procedures are described for the management of Hill-Sachs lesion in special circumstances, Hill-Sachs lesion does not usually need to be addressed.

Anterior Compartment Syndrome after Surgery of Bosworth Fracture-Dislocation of the Ankle - A Case Report - (족관절의 Bosworth 골절-탈구 발생한 전방 구획 증후군 -증례 보고-)

  • Chung, Hyung-Jin;Park, Se-Jin;Choi, Yun-Seok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.221-223
    • /
    • 2004
  • Bosworth fracture-dislocation of ankle is very rare, occurred by eversion and external rotation force. It is known as irreducible fracture by closed method. Also, compartment syndrome after ankle fracture are exceedingly rare. There are only a few reported cases of compartment syndrome after ankle fracture and compartment syndrome are involved commonly deep posterior compartment. We present a case in which a patient had a Bosworth fracturedislocation of the ankle underwent open reduction with internal fixation and subsequently occurred an anterior compartment syndrome of the leg.

  • PDF