• Title/Summary/Keyword: external magnetic field

Search Result 450, Processing Time 0.03 seconds

Coouping Losses of the Round HTS Wires with Stacked Filaments and Radial Filaments (적층형 필라멘트와 방사형 필라멘트 구조를 갖는 원형 초전도선의 결합손실)

  • 신정욱;차귀수;이지광;한송엽
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.40-44
    • /
    • 2000
  • The round HTS wire is easier to handle than the rectangular HTS tape. This paper describes the coupling losses of the round HTS wires by finite element method. Effect of the round HTS wire are considered. Two types of Filaments arrangement, stacked filament and radial filaments, are considered. Calculation results show that coupling losses of the round HTS wire vary only a little with the direction of external magnetic field.

  • PDF

The Characteristics of Magnetized Planar type Inductively Coupled Plasma and its Application to a Dry Etching Process (자화된 평판형 유도 결합 플라즈마의 특성 및 건식 식각에의 응용)

  • Lee, Soo-Boo;Park, Hun-Gun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1364-1366
    • /
    • 1997
  • Planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF

Hall Effect on Unsteady Hartmann Flow with Heat Transfer Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1302-1308
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer taking the Hall effect into consideration. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to an exponential decaying pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the ion slip and the uniform suction and injection on both the velocity and temperature distributions is examined.

3-Port Circulator for X-Band Radar (X-Band 레이더를 위한 3-포트 서큘레이터)

  • Yoon, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.355-362
    • /
    • 2015
  • In this study, we have fabricated 9.385[GHz] circulator that is composed of WR112 waveguide and Ferrite for X-band radar. For designing Ferrite, B/R mode(Below Resonance mode) was used and calculated the condition of 120 degree rotation of the electric field in Ferrite and calculated internal DC magnetic field and external DC magnetic field. Also, dielectric materials of the same shape with Ferrite was filled between two Ferrite for improving the performance of the circulator, including impedance matching, bandwidth, quality factor, insertion loss. To obtain optimum shape of the Ferrite and dielectric material, we used CST MWS. Simulation result of the circulator is that 1.02 : 1 VSWR, -40dB isolation, 0.2dB insertion loss and measurement result is that 1.03 : 1, -38dB, 1.2dB at 9.385[GHz]. We can get good agreement at isolation and VSWR, but insertion loss was 1 dB great than simulation result.

Investigations on the Magneto-optical Properties of Bilayered Co/Ni Micro-patterned Anti-dot Arrays

  • Deshpande, N.G.;Zheng, H.Y.;Hwang, J.S.;Lee, S.J.;Lee, Y.P.;Rhee, J.Y.;Kim, K.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.251-251
    • /
    • 2012
  • A lot of studies are undergoing on the magneto-optical (MO) properties of patterned magnetic systems for the reason that they have potential application to information technology such as ultrahigh-speed computing. Moreover, they can be considered as the future candidates for high-density MO storage devices. Not only the technical aspects, but there have been also tremendous interests in studying their properties related to the fundamental physics. The MO Kerr-rotation effects (both in reflected and the diffracted modes) and the magnetic force microscopy (MFM) are very useful techniques to investigate the micromagnetic properties of such periodic structures. Hence, in this study, we report on the MO properties of bilayered Cobalt (Co)/ nickel (Ni) micro-patterned anti-dot arrays. Such a ferromagnetic structure was made by sequentially depositing co (40 nm)/Ni (5 nm) bilayer on a Si substrate. The anti-dot patterning with hole diameter of $1{\mu}m$ was done only on the upper Co layer using photolithography technique, while the Ni underlayer was kept uniform. The longitudinal Kerr rotation (LKR) of the zeroth- and the first-order diffracted beams were measured at an incidence of $30^{\circ}$ by using a photoelastic modulator method. The external magnetic field was applied perpendicularly to the reflected and the diffracted beams using an electromagnet capable of a maximum field of ${\pm}5$ kOe. Significantly, it was observed that the LKR of the first-order diffracted beam is nearly 4 times larger than that of the zeroth-order beam. The simulated results for the hysteresis loops matched qualitatively well with the experimentally obtained ones. In conjunction with the LKR, we also investigated the magnetic-domain structure by using a MFM system, which were analyzed to elucidate the origin of the enhanced MO rotation.

  • PDF

A Study on the Site analysis of Jongmyo area -With Feng-shui theory and Geomagnetic Field

  • Han, Jong-Koo;Park, Tong-So
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.41-47
    • /
    • 2002
  • East Asian explain the changes of substance happened on earth and those of human life with the conceptual frame of "Gi-ki"(地氣; earth vital energy) and organize them by the system of "Feng-shui(風水) theory. The core of Feng-shui theory is reading the expression of the nature and feeling the Gi-ki from the expression. One of the properties of the earth is that the earth has a magnetic field associated with it- the Geomagnetic field. The geomagnetic field is produced by a combination of the effects of electric currents in the earth's liquid core, the magnetization of crustal rocks, external electric current systems that surround the earth and currents induced in the outer layers of the earth by magnetic field variations. The sameness of logic between Feng-shui and geopathic zones is that both are concerned with the discrimination of site and the energy of places, in other words both disciplines are concerned with how the environment can influence people. In this context the operation of Gj-ki can be related with the effect caused by geomagnetic field on site. In this study Jongmyo(宗廟), one of the representative traditional architecture in Korea is selected because the site selection and building layout follows Feng-shui faithfully according to Taejo silok (太祖實錄, Annals of King Taejo). Observing the landforms surrounding Jongmyo, Jongmyo is apparently located in auspicious places named Gumge Poranhyoeng(金鷄抱卵形, a Feng-shui landscape of golden hen sitting on eggs). The geomagnetic investigation of Jongmyo shows that the geomagnetic values of Toekan(the space near Hyeol) are relatively high and uniform and those of Sangweoldae and Haweoldae are decreased in accordance with the distance. The result shows that there is possibility that Feng-shui has scientific basis related with geomagnetic field. Feng-shui theory can suggest a direction for designing the sustainable building for living with nature.

Synthesis of the Multifunctional Core/Intermediate/Shell Nanoparticles: Tunable Magnetic and Photoluminescence Properties (자성 및 발광 특성이 조절 가능한 다기능 코어/중간체/쉘 나노 입자 합성)

  • Kim, Mun-Kyoung;Kim, Seyun;Moon, Kyoung-Seok;Shin, Weon Ho;Jeong, Hyung Mo
    • Journal of Powder Materials
    • /
    • v.26 no.6
    • /
    • pp.463-470
    • /
    • 2019
  • Fe3O4/SiO2/YVO4:Eu3+ multifunctional nanoparticles are successfully synthesized by facile stepwise sol-gel processes. The multifunctional nanoparticles show a spherical shape with narrow size distribution (approximately 40 nm) and the phosphor shells are well crystallized. The Eu3+ shows strong photoluminescence (red emission at 619 nm, absorbance at 290 nm) due to an effective energy transfer from the vanadate group to Eu. Core-shell structured multifunctional nanoparticles have superparamagnetic properties at 300 K. Furthermore, the core-shell nanoparticles have a quick response time for the external magnetic field. These results suggest that the photoluminescence and magnetic properties could be easily tuned by either varying the number of coating processes or changing the phosphor elements. The nanoparticles may have potential applications for appropriate fields such as laser systems, optical amplifiers, security systems, and drug delivery materials.

The Motion of Plasma in an Excited Quiescent Filament

  • Song, Dong-Uk;Chae, Jong-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.48.2-48.2
    • /
    • 2010
  • Quiescent filaments are bigger, more stable, and longer lived than active region filaments. So, the shape of a quiescent filament changes little during its lifetime and a fast motion of plasma rarely occurs. But when it is dynamically influenced by external phenomena, a rapid motion of plasma may temporarily occur. By analyzing the motion of plasma we can infer some of the magnetic structure permeating such an excited quiescent filament. We analyzed the H$\alpha$ images of a quiescent filament in the northern hemisphere that was observed at Big Bear Solar Observatory on 2004 August 2, and found that: 1) the filament was excited by a flare that occurred in a remote active region located in the southern hemisphere, 2) By this excitation, a part of the filament moved vertically upward and horizontally out of main body, and then it stayed there without much motion. Then after it moved vertically downward and horizontally to the main body, 3) the final position of plasma, however, was not the same as the initial position, being about 14Mm above it. We suggest that the filament was initially in a more or less static equilibrium. The excitation of the filament broke the initial equilibrium, and then brought about a new one that is different from the original one. Since the filament should have magnetic field, it is likely that both the equilibria may have been maintained by diplike magnetic structures. Furthermore, the transition from one equilibrium to another as we inferred should have accompanied a permanent change of magnetic configuration as well.

  • PDF

Effects of 00 Hz Horizontally Polarized Magnetic Fields on Embryo-fetal Development in SD Rats (SD 랫드의 배 .태자발생에 대한 60 Hz 수평자계의 영향)

  • 정문구;김종춘;명성호;김상범;이동일
    • Toxicological Research
    • /
    • v.17 no.4
    • /
    • pp.279-286
    • /
    • 2001
  • Recently, there is an increasing nationwide concern in Korea that exposure to electric and magnetic fields in the home environment may not be safe in humans. To identify possible effects of horizontally polarized magnetic fields (MF) exposure on embryo-fetal development, timed-mated female Sprague-Dawley rats (24/group) received continuous exposure to 60 Hz MF at field strengths of 0 Gauss (sham control), 50mG,833 mG, or 5000 mG. Dams received MF of sham exposures for 22hr/day on gestation days 6 through 20. Experimentally generated MF were monitored continuously througout the study. There was no evidence of maternal toxicity of developmental toxicity in any MF-exposed groups. Mean maternal body weight, organ weights, and gross findings in groups exposed to MF did not differ from those in sham control. No significant differences in fetal deaths, fetal body weight, and placental weight were observed between MF-exposed groups and sham control. External, visceral, and skeletal examination of fetuses demonstrated no significant differences in the incidence of fetal malformations between MF-exposed and sham control groups. In conclusion, exposure of pregnant Sprague-Dawley rats to 60 Hz at MF strengths up to 5000 mG during gestation day 6-20 did not produce any biologically significant effect in either dams of fetuses.

  • PDF