• Title/Summary/Keyword: external heart

Search Result 189, Processing Time 0.028 seconds

Dynamic Behavior Analysis of Mechanical Monoleaflet Heart Valve Prostheses (기계식 一葉심장밸브의 동적거동 해석)

  • 천길정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2090-2097
    • /
    • 1992
  • In this paper, fluttering behavior of mechanical monloleaflet heart valve prosthesis was analyzed taking into consideration of the impact between the valve occluder and the stopper. The motion of valve occluder was modeled as a rotating system, and equations were derived by employing the moment equilibrium conditions. Lift force, drag force, gravity and buoyancy were considered as external forces acting on the valve occluder. The 4th order Runge-Kutta method was used to solve the equations. The results demonstrated that the occluder reaches steady eguilibrium position only after damped vibration. The mean damping ratio is in the range of 0.197-0.301. Fluttering frequency does not have any specific value, but varies as a function of time. It is in the range of 11-84Hz. Valve opening appears to be affected by the orientation of the valve relative to gravitational forces.

Development of Real-time Heart Rate Measurement Device Using Wireless Pressure Sensor (무선 압력센서를 이용한 실시간 맥박수 측정기 개발)

  • Choi, Sang-Dong;Cho, Sung-Hwan;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.284-288
    • /
    • 2016
  • Among the various physiological information that could be obtained from human body, heartbeat rate is a commonly used vital sign in the clinical milieu. Photoplethysography (PPG) sensor is incorporated into many wearable healthcare devices because of its advantages such as simplicity of hardware structure and low-cost. However, healthcare device employing PPG sensor has been issued in susceptibility of light and motion artifact. In this paper, to develop the real-time heart rate measurement device that is less sensitive to the external noises, we have fabricated an ultra-small wireless LC resonant pressure sensor by MEMS process. After performance evaluation in linearity and repeatability of the MEMS pressure sensor, heartbeat waveform and rate on radial artery were obtained by using resonant frequency-pressure conversion method. The measured data using the proposed heartbeat rate measurement system was validated by comparing it with the data of an commercialized heart rate measurement device. Result of the proposed device was agreed well to that of the commercialized device. The obtained real time heartbeat wave and rate were displayed on personal mobile system by bluetooth communication.

A study for Mental disorder of Women II -focus on the cause of treatment- (부인(婦人) 정신장애에 대한 연구 II - 치료 중심으로)

  • Kim, Geun-Woo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.53-64
    • /
    • 2005
  • Objects : This study was aimed to investigate the treatment on Mental disorder of Women. Methods : Research data is based on Buindaejoenyangbang and Dong-uibogam. And study the treatment in Mental disorder of Women. Results : 1. Owing to women's physiological extraordinary nature, Mental disorder of Women’s treatment does not match Dongyipogam’s about the same symptoms. 2. Most of happing the symptom is due to blood Wind(four flavors) and deficiency of the Heart, treatments are dispelling Wind, tonifying blood of the Heart and calming the spirit. 3. At postpartum, Mental disorder of Women’s causes are deteriorating blood vanquished blood and external affections with a blood deficiency from the loss of blood, treatments are tonifying the blood, expel Wind and clear Cold and remove blood stagnation to promote regeneration. Conclusion : The results suggest that the extraordinary nature of the circumstances due to women specific pathology must be considered.

  • PDF

Anesthetic management of a patient with branchio-oto-renal syndrome

  • Tsukamoto, Masanori;Yokoyama, Takeshi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.3
    • /
    • pp.215-217
    • /
    • 2017
  • Branchio-oto-renal syndrome (BOR) is a rare autosomal dominant disorder. The features include branchial cysts, hearing loss, ear malformation, preauricular pits, retrognathia, congenital heart disease, and renal abnormalities. However, anesthetic management of these patients has seldom been reported. We report a case in which general anesthesia was performed for dental treatment in a patient with BOR. Airway management, renal function, and hemodynamic changes can be of critical concern during anesthetic management. A 13-year-old girl diagnosed with BOR had severe right hearing loss, right external ear malformation, renal abnormalities, and postoperative patent ductus arteriosus (PDA). Dental extraction under general anesthesia was scheduled for a supernumerary tooth. The procedure was completed with sufficient urine volume, adequate airway management, and stable hemodynamics.

Impact Behavior Analysis of Mechanical Monoleaflet Heart Valve Prostheses in the Opening Phase

  • Cheon, Gill-Jeong;Chandran, K.B.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.235-244
    • /
    • 1992
  • In this paper, fluttering behavior of mechanical monoleaflet tilting disc heart valve prostheses during the opening phase was analyzed taking into consideration the impact between the occluder and the guiding strut at the fully open position. The motion of the valve occluder was modeled as a rotating system, and equations were derived by employing the moment equilibrium principle. Forces due to lift, drag, gravity and buoyancy were considered as external forces acting on the occluder. The 4th order Runge-Kutta method was used to solve the governing equations. The results iimonstrated that the occludes reaches steady equilibrium position only after damped vibration. Fluttering frequency varies as a function of time after opening and is in the range of 8-84 Hz. Valve opening appears to be affected by the orientation of the valve relative to gravitational force. The opening velocities are in the range of 0.65-1.42m/sec and the dynamic loads by impact of the occludes and the strut are in the range of 90-190 N.

  • PDF

Dynamic Behavior Analysis of Mechanical Bileaflet Heart Valve Prosthesis (기계식 이엽심장밸브의 동적거동 해석)

  • 천길정
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.149-156
    • /
    • 1991
  • In this paper, fluttering behavior of mechanical bileaflet heart valve prosthesis was analyzed taking into consideration of the impact between valve plate and stopper Vibration system of the valve was modeled as a rotating system, and equations are induced by moment equilibrium equations. Lift force, drag force, gravity and buoyancy were considered as external forces acting on the valve plate/ The 4th order Runge-Kutta method was used to solve the equations. Valve plate does not come to the static equilibrium position at a stretch, but come to that position after under damping vibration. Damping ratio increases as the cardiac optput increases, and the mean damping ratio is in the range of 0.16~40.25. Fluttering frequency does not have any specific value, but varies as a function of time. It is in the range of 10~40Hz. Valve opening appears to be affected by the orientation of the of the valve relative to gravitational forces.

  • PDF

A study on the generation of seven-emotion in the east-west medicine (칠정(七情)의 생성(生成)에 대한 동서의학적(東西醫學的) 고찰(考察))

  • Song, Ho-chul;Kim, Dong-hee;Kim, Sung-hoon
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.183-192
    • /
    • 2000
  • 1. The emotion is given before birth, and because of not perfect of human being's consciseness, individual differance exist. 2. Every emotion act first on the heart and following other organ which possess each of the five emotion. Therfore the heart plays impartant role on the emotion and emerge five organ in the oriental medicine theory. 3. The emotion was expressed by external reagent, but the more importante reagent is internal situation such as qi(氣), xie(血), yin(陰), yang(陽), according to these reagent the existing time and strength is different. 4. The emotion is different according to the weak-strong and big-small of zang-fu(臟腑), and the size of zang-fu(臟腑) is determined by emotional specificity in the si-xiang medicinal (四象醫學)theory.

  • PDF

Review of cranioplasty after decompressive craniectomy

  • Cho, Yong Jun;Kang, Suk Hyung
    • Korean Journal of Neurotrauma
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • Cranioplasty is an in evitable operation conducted after decompressive craniectomy (DC). The primary goals of cranioplasty after DC are to protect the brain, achieve a natural appearance and prevent sinking skin flap syndrome (or syndrome of the trephined). Furthermore, restoring patients' functional outcome and supplementing external defects helps patients improve their self-esteem. Although early cranioplasty is preferred in recent year, optimal timing for cranioplasty remains a controversial topic. Autologous bone flaps are the most ideal substitute for cranioplasty. Complications associated with cranioplasty are also variable, however, post-surgical infection is most common. Many new materials and techniques for cranioplasty are introduced. Cost-benefit analysis of these new materials and techniques can result in different outcomes from different healthcare systems.

Wireless Magnetic Pump: Characteristics of Magnetic Impellers and Medical Application

  • Song, Moon Kyou;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.344-351
    • /
    • 2017
  • Wireless magnet pumps are used in medical applications and are particularly useful as artificial heart ventricular assist devices (VADs). To investigate wireless operation of magnetic pumps, we fabricated three types of magnetic impellers using bonded magnets by blending magnetic powders of SmFeN, NdFeB, and Sr-ferrite. We investigated the magnetic properties of the fabricated magnetic impellers, which are driven by the application of magnetic coupling with an external driving magnet or external coil system, without a driving motor, shaft, or mechanical bearings. The use of wireless magnetic pumps is therefore not complicated by critical issues of size, heat, and vibration, which are very important issues for blood pumps. The magnetic properties of the impellers, such as their rotational speed, driving torque and hydrodynamic performance, determine their wireless driving ranges. We conducted performance evaluations of the impeller's magnetic wireless manipulation, heat, and vibration. In addition, we carried out an animal test to confirm the suitability of the wireless magnetic pumps for use as biventricular assist devices (BiVADs).

A Bibliographic Study on The Research of nosebleeding by damaged lung (상폐(傷肺)에 의(依)한 비출혈(鼻出血)의 문헌적(文獻的) 고찰(考察))

  • Kim, Sung-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.45-55
    • /
    • 1991
  • It has been known that the nosebleeding is a king hemorrhage occured to be damaged yang-rak (陽略) & lung. the results obtained were as follows; 1. The cause of nosebleeding were divided internal external, these were lung-heat(肺實熱), wind-heat(風熱), dry-heat(煥熱), wind-cold(風寒), summer-heat(暑熱), and those were transporting of Liver-fire(肝火犯肺), Liver-kidney-fire(肝腎陰虛熱傷肺), Stomach-fire(胃火熾盛), Heart-fire(心火千肺). 2. The treatment of external ; Chungpaesulyul(淸肺泄熱), Yanghyuljihyul(凉血止血), Sanpungchungyul(散風淸熱), Jaeumchungjo(滋陰淸煥). 3. The treatment of internal ; Chungkansahwa(淸肝瀉火), Yanghuljihyul(凉血止血), Jayumganghwa(滋陰降火), Chunguysahwa(淸胃瀉火). The cause of nosebleeding was almost heat (fire), and the treatment were Sanpyo(散表) & Chungri(淸裏).

  • PDF