• 제목/요약/키워드: external bars

검색결과 80건 처리시간 0.022초

RC beams retrofitted using external bars with additional anchorages-a finite element study

  • Vasudevan, G.;Kothandaraman, S.
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.415-428
    • /
    • 2015
  • Study on flexural retrofitting of RC beams using external bars with additional intermediate anchorages at soffit is reported in this paper. Effects of varying number of anchorages in the external bars at soffit were studied by finite element analysis using ANSYS 12.0 software. The results were also compared with available experimental results for beam with only two end anchorages. Two sets of reference and retrofitted beam specimens with two, three, four and five anchorages were analysed and the results are reported. FE modeling and non-linear analysis was carried out by discrete reinforcement modeling using Solid65, Solid45 and Link8 elements. Combin39 spring elements were used for modeling the frictional contact between the soffit and the external bars. The beam specimens were subjected to four-point bending and incremental loading was applied till failure. The entire process of modeling, application of incremental loading and generation of output in text and graphical format were carried out using ANSYS Parametric Design Language.

Experimental evaluation of external beam-column joints reinforced by deformed and plain bar

  • Adibi, Mahdi;Shafaei, Jalil;Aliakbari, Fatemeh
    • Earthquakes and Structures
    • /
    • 제18권1호
    • /
    • pp.113-127
    • /
    • 2020
  • In this study, the behavior of external beam-column joints reinforced by plain and deformed bars with non-seismic reinforcement details is investigated and compared. The beam-column joints represented in this study include a benchmark specimen by seismic details in accordance with ACI 318M-11 requirements and four other deficient specimens. The main defects of the non-seismic beam-column joints included use of plain bar, absence of transverse steel hoops, and the anchorage condition of longitudinal reinforcements. The experimental results indicate that using of plain bars in non-seismic beam-column joints has significantly affected the failure modes. The main failure mode of the non-seismic beam-column joints reinforced by deformed bars was the accumulation of shear cracks in the joint region, while the failure mode of the non-seismic beam-column joints reinforced by plain bars was deep cracks at the joint face and intersection of beam and column and there was only miner diagonal shear cracking at the joint region. In the other way, use of plain bars for reinforcing concrete can cause the behavior of the substructure to be controlled by slip of the beam longitudinal bars. The experimental results show that the ductility of non-seismic beam-column joints reinforced by plain bars has not decreased compared to the beam-column joints reinforced by deformed bars due to lack of mechanical interlock between plain bars and concrete. Also it can be seen a little increase in ductility of substructure due to existence of hooks at the end of the development length of the bars.

In-plane seismic performance of masonry wall retrofitted with prestressed steel-bar truss

  • Hwang, Seung-Hyeon;Kim, Sanghee;Yang, Keun-Hyeok
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.459-469
    • /
    • 2020
  • An external prestressed steel-bar truss unit was developed as a new strengthening technology to enhance the seismic performance of an in-plane masonry wall structure while taking advantage of the benefits of a prestressed system. The presented method consists of six steel bars: two prestressed vertical bars to introduce a prestressing force on the masonry wall, two diagonal bars to resist shear deformation, and two horizontal bars to maintain the configuration. To evaluate the effects of this new technique, four full-scale specimens, including a control specimen, were tested under combined loadings that included constant-gravity axial loads and cyclic lateral loads. The experimental results were analyzed in terms of the shear strength, initial stiffness, dissipated energy, and strain history. The efficiency of the external prestressed steel-bar truss unit was validated. In particular, a retrofitted specimen with an axial load level of 0.024 exhibited a more stable post behavior and higher energy dissipation than a control specimen with an observed complete sliding failure. The four vertical bars of the adjacent retrofitting units created a virtual column, and their strain values did not change until they reached the peak shear strength. The shear capacity of the masonry wall structure with external prestressed steel-bar truss units could be predicted using the model suggested by Yang et al.

강봉으로 보강된 RC 사각기둥의 내진 성능 평가 (Seismic Capacity Evaluation of Rectangular RC Columns Strengthened with Steel Bars)

  • 이동민;이성철;신동호;오창국
    • 한국전산구조공학회논문집
    • /
    • 제36권5호
    • /
    • pp.283-293
    • /
    • 2023
  • 최근 국내에서 연간 지진 발생 횟수가 꾸준히 증가함에 따라 공공시설물에 대한 내진 보강의 필요성이 더욱 대두되고 있다. 이 연구에서는 사각 단면을 가진 철근콘크리트 기둥에서 강봉보강의 유무에 따른 내진 성능 개선 효과를 분석하기 위해 비선형 유한요소해석을 수행하였으며, 검증을 위해 구조실험결과와 비교하였다. 분석 결과, 이 연구에서 수행한 유한요소해석이 실제 강봉보강공법을 적용한 철근콘크리트 기둥의 구조 거동을 합리적으로 잘 묘사하는 것으로 나타났다. 또한, 해석 및 실험 모두 강봉보강공법 적용으로 인해 파괴모드가 취성파괴에서 연성파괴로 전환되었으며, 강도와 연성도 모두 증가하는 것으로 나타났다. 따라서, 강봉보강공법 적용을 통해 기존 철근콘크리트 기둥의 내진 성능을 효과적으로 증진시킬 수 있는 것으로 판단된다. 이 연구의 주요 결과는 향후 설계 방안 마련 등 관련 연구에 유용할 것으로 기대된다.

Barred Galaxies Are More Abundant in Interacting Clusters: Bar Formation by Cluster-Cluster Interactions

  • Yoon, Yongmin;Im, Myungshin;Lee, Seong-Kook;Lee, Gwang-Ho;Lim, Gu
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.35.1-35.1
    • /
    • 2018
  • Bars are commonly found in disk galaxies. However, how bars form is yet unclear. There are two common pictures for the bar formation mechanism. Bars form through a physical process inherent in galaxies, or through and external process like galaxy-galaxy interaction. In this paper, we present the observational evidence that bars can form from another channel, namely a cluster-cluster interaction. We examined 105 galaxy clusters at 0.015

  • PDF

Influence of different fatigue loads and coating thicknesses on service performance of RC beam specimens with epoxy-coated reinforcement

  • Wang, Xiao-Hui;Gao, Yang;Gao, Run-Dong;Wang, Jing;Liu, Xi-La
    • Computers and Concrete
    • /
    • 제19권3호
    • /
    • pp.243-256
    • /
    • 2017
  • Epoxy-coated reinforcing bars are widely used to protect the corrosion of the reinforcing bars in the RC elements under their in-service environments and external loads. In most field surveys, it was reported that the corrosion resistance of the epoxy-coated reinforcing bars is typically better than the uncoated bars. However, from the experimental tests conducted in the labs, it was reported that, under the same loads, the RC elements with epoxy-coated reinforcing bars had wider cracks than the elements reinforced with the ordinary bars. Although this conclusion may be true considering the bond reduction of the reinforcing bar due to the epoxy coating, the maximum service loads used in the experimental research may be a main reason. To answer these two phenomena, service performance of 15 RC beam specimens with uncoated and epoxy-coated reinforcements under different fatigue loads was experimentally studied. Influences of different coating thicknesses of the reinforcing bars, the fatigue load range and load upper limit as well as fatigue load cycles on the mechanical performance of RC test specimens are discussed. It is concluded that, for the test specimens subjected to the comparatively lower load range and load upper limit, adverse effect on the service performance of test specimens with thicker epoxy-coated reinforcing bars is negligible. With the increments of the coating thickness and the in-service loading level, i.e., fatigue load range, load upper limit and fatigue cycles, the adverse factor resulting from the thicker coating becomes noticeable.

고장력 인장봉으로 보강된 RC보의 휨거동에 관한 해석적 연구 (An Analytical Study on the Flexural Behavior of RC Beams Strengthened with High Tension Bars)

  • 신경재;김병준
    • 한국강구조학회 논문집
    • /
    • 제19권3호
    • /
    • pp.259-270
    • /
    • 2007
  • 본 논문은 고장력 인장봉에 의해 보강된 RC보의 휨거동을 평가하기 위한 해석적 방법을 제시하고 있다. 본 연구에 대한 선행 실험결과를 이용하였다. 실험 논문에서는 외부 강봉 보강의 이점에 대해서 소개하고 있다. 휨거동을 평가하기 위해 본 논문은 해석적 방법으로 단순누가산정의 방법을 제시하고 있다. 이 방법은 기본적으로 고장력 인장봉에 의해 보강된 RC보가 받는 전체하중은 강봉이 없는 RC보가 받는 하중과 강봉 자체가 받는 하중의 합과 같다고 가정한 것이다. 추가로 강봉에 의해 발생하는 축력과 강봉에 주어진 프리스트레스트에 대하여 고려를 하였다. 실험 결과와 이론해석의 결과값을 비교하여 단순누가산정 방법은 고장력 인장봉에 의해 보강된 RC보의 비선형 휨거동을 예측함에 있어서 비교적 정확한 상관관계를 보여주고 있다.

External retrofit of beam-column joints in old fashioned RC structures

  • Adibi, Mahdi;Marefat, Mohammad S.;Arani, Kamyar Karbasi;Zare, Hamid
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.237-250
    • /
    • 2017
  • There has been increasing attention in many countries on seismic retrofit of old fashioned RC structures in recent years. In such buildings, the joints lack transverse reinforcement and suffer inadequate seismic dimensional requirements and the reinforcement is plain bar. The behavior of the joints is governed by sliding of steel bars and diagonal shear failure is less influential. Different methods to retrofit beam-column joints have been proposed in the literature such as wrapping the joint by FRP sheets, enlargement of the beam-column joint, and strengthening the joint by steel sheets. In this study, an enlargement technique that uses external prestressed cross ties with steel angles is examined. The technique has already been used for substructures reinforced by deformed bars and has advantages such as efficient enhancement of seismic capacity and lack of damage to the joint. Three reference specimens and two retrofitted units are tested under increasing lateral cyclic load in combination with two levels of axial load. The reference specimens showed relatively low shear strength of 0.150${\surd}$($f_c$) and 0.30${\surd}$($f_c$) for the exterior and interior joints, respectively. In addition, relatively brittle behavior was observed and large deformations extended into the panel zone of the joints. The retrofit method has increased ductility ratio of the interior beam-column joints by 63%, and energy dissipation capacity by 77%, relative to the control specimen; For external joints, these values were 11%, and 94%. The retrofit method has successfully relocated the plastic joints far from the column face. The retrofit method has improved shear strength of the joints by less than 10%.

지속 하중하에서 철근콘크리트 부재의 염화물 침투특성에 따른 철근부식에 관한 연구 (A Study on the Reinforcing Bar Corrosion Caused by Permeation of Chloride Ion Under Sustained Load)

  • 최일호;김형래;윤상천;지남용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.779-782
    • /
    • 1999
  • This study was carried out to estimate the effects of the loading conditions on the corrosion of reinforcing bars and permeation of chloride ion. The permeation of chlorides depends not only on the transfer properties in concrete but also on the load applied in the case of reinforced concrete structures. Recent studies reported that the loading conditions affected the corrosion rate of the reinforcing bars under existence of an external current supply. But it was not reported that loading conditions affected corrosion of reinforcing bar caused by the characteristics of permeation and the process of cracking. In this experiment, it was shown that the corrosion of reinforcing bars and the characteristics of permeating were greatly affected by the loading conditions.

  • PDF