• Title/Summary/Keyword: exterior joints

Search Result 126, Processing Time 0.024 seconds

A Field Investigation of Defect Type for Development of Maintenance Manual of Han-ok (한옥 유지관리매뉴얼 개발을 위한 결함 유형 현장 조사)

  • Lee, Jong Shin;Choi, Gwang Sik;Yang, Jeong Moo
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.3
    • /
    • pp.302-308
    • /
    • 2013
  • To collection of field data for development of maintenance manual of Han-ok, we investigated defects which occurred in members of Han-ok by field investigation. The noticeable defects were wood cracks, gaps that developed between wood pillar and wall or wood window frame and tenon joints. The most common biological defect was blue stain which was created in log. The mold generation was observed on exterior wood and wall which get wet by precipitation. The gaps between members of Han-ok pointed out as defect that is urgently improved by residents of Han-ok. The reason is mainly due to poor of insulation in winter by bad confidentiality. The maintenance work of defect such as gap was conducted personally. As a result, the repair parts were ugly for unfamiliar repair work.

  • PDF

NEW TECHNIQUE IN THE USE OF VIBRO-ACOUSTICAL RECIPROCITY WITH APPLICATION TO THE NOISE TRANSFER FUNCTION MEASUREMENT

  • Ko, K.H.;Kook, H.S.;Heo, S.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.173-177
    • /
    • 2006
  • A noise transfer function(NTF) is the frequency response function between an input force applied to an exterior point of a vehicle body and the resultant interior sound pressure usually measured at the driver's ear position. It represents the measure of noise sensitivity for the output force transmitted to the joints between the body and chassis. The principle of vibro-acoustic reciprocity is often utilized in the measurement of NTF. One difficulty in using the volume source is that most of the previously proposed methods require the knowledge of the volume velocity of the acoustic source in advance. A new method proposed in the present work does not require any calculation related with the volume velocity of the acoustic source, but still yields even more accurate results both in the amplitude and phase of the NTF. In the present work, the new method is applied to obtain NTF data for a midsize sedan.

Static behavior of novel RCS through-column-type joint: Experimental and numerical study

  • Nguyen, Xuan Huy;Le, Dang Dung;Nguyen, Quang-Huy
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.111-126
    • /
    • 2019
  • This paper deals with experimental investigation and modeling of the static behavior of a novel RCS beam-column exterior joint. The studied joint detail is a through-column type in which an H steel profile totally embedded inside RC column is directly welded to the steel beam. The H steel profile was covered by two supplementary plates in the joint area in order to avoid the stirrups resisting shear in the joint area. Two full-scale through-column-type RCS joints were tested under static loading. The objectives of the tests were to examine the connection performance and to highlight the contribution of two supplementary plates on the shear resistance of the joint. A reliable nonlinear 3D finite element model was developed using ABAQUS software to predict the response and behavior of the studied RCS joint. An extensive parametric study was performed to investigate the influences of the stirrups, the encased profile length and supplementary plate length on the behavior of the studied RCS joint.

Cyclic-Leading Tests of RC Exterior Beam-Column Joints with Non-Seismic Detailing (비내진 상세를 가진 RC 외부접합부의 반복 횡하중 실험)

  • Cha, Byung-Gi;Ko, Dong-Woo;Woo, Sung-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.11-16
    • /
    • 2003
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with non-seismic detailing. To do this, an exterior beam-column subassemblage was selected from a ten story RC building and six 1/3-scale specimens were manufactured with three variables; (1) with and without slab, (2) upward and downward direction of anchorage for the bottom bar in beams, and (3) with and without hoop bars in the joint region. The test results have shown that (1) the existence of slab increased the strength in positive and negative moment, 25% and 52%, respectively; (2) the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) caused the 8% reduction of strength and the early strength degradation in comparison with the case of seismic details; and (3) the existence of hoop bars in the joint region shows significant role in preventing the pull-out.t.

A Study on the Characteristics of Organic Design of Alvar Aalto (알바 알토(Alvar Aalto)의 유기적 디자인 특성에 관한 연구)

  • 이종선
    • Korean Institute of Interior Design Journal
    • /
    • no.12
    • /
    • pp.91-99
    • /
    • 1997
  • Alvar Aalto has pursued National Romanticism, cultural art movement in scandinavian peninsula, organic concepts of growth and suitability, comprehensive view of nature including a possibility of coexistance of human-being and the nature well harmonized. For instance, his design expressed local features of the nature, human emotions instead of geometical arts and mathematical principles. It is noteworthy today that he built up the identity with satrical architecture vocabularies, different from modern arch-itechtural idiology. The characte-ristics of his design related to interior architecture are collectively as follows; The first, Space discontinuity of the interior and exterior, gradual process by joints which are inclined to collage with many shapes in plan and section of the space and such joints are adjusted by sensual ways and stressed with inner collectivity in his works. The second, He pursued the architectural orderfor modern irreqularity, various changes and sensual harmonies. As result, free curved line, fan shape and irregular modeling were individually expressed by technics of natural features and national characteristics of Finland. The third, Organic synthesis. A harmony through med-ums in its space, materials and space effectiveness relations are made and expressed for mixed design especially harmonized of all the materials he planned, entire harmony with total design, itemized details, materials and furnitures in entire space. The fourth, The interest of the nature based on his sense harmonized with nature made him mainly use native materials, lumbers and red bricks masonry and showed and arranged various interior sky light and grazed in to let natural light in, harmony with garden to sensually cohere to the nature and courtyard, etcetera. His major subject are to direct architectural developments through the nature and human-being in his works. At this point, it is considered that his direction of the locality and independence as a human-being made the concepts of organic space structure possible.

  • PDF

Stress Distribution in Construction Joint of Prestressed Concrete Bridge Members with Tendon Couplers (고강도 철근콘크리트 보-기둥 외부 접합부의 전단 거동에 관한 실험)

  • Park Ki-Choul
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.535-542
    • /
    • 2005
  • Two series of experiments on the performance of beam-column joints in High-Strength Reinforced concrete frames were carried out. Main experimental parameters were : concrete strength, column axial load and amount of joint hoop reinforcement. Test result showed that the ultimate shear strength of exterior joints increased of column axial compressive force and the amount of the joint hoop reinforcements. Through the regression analysis on the 24data, the following equation is obtained $jv_u=(2.935{\times}10-3\;{\rho}jw{\cdot}fy\;+\;0.365){\sqrt{f_{ck}}}$

Improvement and Seismic Performance Evaluation of RC Exterior Beam-Column Joints Using Recycled Coarse Aggregate with Hybrid Fiber (순환굵은골재 치환과 하이브리드섬유 혼입에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능 평가 및 개선)

  • Ha, Jae-Hoon;Ha, Gee-Joo;Shin, Jong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.160-169
    • /
    • 2015
  • In this study, experimental research was carried out to improve the seismic performance of reinforced concrete exterior beam-column joint regions using replacing recycled coarse aggregate with hybrid fiber (steel fiber+PVA fiber) in existing reinforced concrete building. Therefore it was constructed and tested seven specimens retrofitting the beam-column joint regions using such retrofitting materials. Specimens, designed by retrofitting the beam-column joint regions of reinforced concrete building, were showed the stable failure mode and increase of load-carrying capacity due to the effect of crack control at the times of initial loading and bridge of retrofitting hybrid fiber during testing. Specimens BCJGPSR series, designed by the retrofitting of replacing recycled coarse aggregate with hybrid fiber in reinforecd beam-column joint regions were increased its maximum load carrying capacity by 1.01~1.04 times and its energy dissipation capacity by 1.06~1.29 times in comparison with standard specimen BCJS. Also, specimen $BCJGPSR_1$ were increased its energy dissipation capacity by 1.33~1.65 times in comparison with specimens BCJS, BCJP and BCJGPR series for a displacement ductility of 9.

Behavior of Non-seismic Detailed Low-Rise R/C Exterior Beam-to-Column Joints Subjected to Cyclic Loading (반복 하중을 받는 비내진 저층 RC 구조물의 외부 기둥-보 접합부의 거동)

  • Sur, Man-Sik;Chang, Chun-Ho;Kim, Young-Moon
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Seismic design code has been performed since 1988 in Korea, so it has not been applied to low-rise reinforced concrete buildings which had been built before 1988. Those building have been designed only for gravity loads based on non-seismic code, Therefore, even minor earthquake occurred, those buildings might have serious damages. In this paper, to investigate the behavior of low-rise reinforced concrete moment resisting frame which had been built in according to the building code of Korea that had been published before 1988, two type of 1/2 scaled exterior beam-column subassemblies which have non-seismic detailing based on the building code of Korea were constructed and tested with reversed cycling loading under the displacement control method. The special features of joint with non-seismic detailing is that there is no transverse reinforcement in the joint. In tests, cracks pattern, strength degradation, loss of stiffness, energy dissipation and the slippage of beam and column bars were investigated. Cracks did not occurred in the joint even seismic loading of 0.12g which is considered as peak ground acceleration in Korea was applied. And increasing seismic loading above 0.12g shear crack happened in the joint which have not transverse beam.

Evaluation of Safety by Structural Analysis of Traditional Wooden Building (전통 목조 건축물의 구조해석에 의한 안전성 평가)

  • Jo, Sung-San;Kim, Hyong-Kee;Park, Bok-Man
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.149-158
    • /
    • 2005
  • In order to grasp and evaluate the characteristics and the safety of traditional wooden building, we select one of the representative traditional wooden building, Buseoksa Muryangsujeon in this study. After the two and three-dimensional structural analysis of this building are performed, the results are compared and analyzed. Following main conclusion are obtained: 1) By comparison between the results of two and three-dimensional structural analysis, they show that the exterior members of this building tend to transfer more load in the three-dimensional analysis. 2) The result of three-dimensional structural analysis shows that the every member stress of Buseoksa Muryangsujeon except Chobang and Jangyon is below allowable stress. 3) For exact modelling of joints of members in traditional wooden building such as Gongpo, it is necessary to accumulate and analyze the technical data through structural test and systematic analysis study.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.