• Title/Summary/Keyword: extended SSD

Search Result 6, Processing Time 0.023 seconds

Extended Buffer Management with Flash Memory SSDs (플래시메모리 SSD를 이용한 확장형 버퍼 관리)

  • Sim, Do-Yoon;Park, Jang-Woo;Kim, Sung-Tan;Lee, Sang-Won;Moon, Bong-Ki
    • Journal of KIISE:Databases
    • /
    • v.37 no.6
    • /
    • pp.308-314
    • /
    • 2010
  • As the price of flash memory continues to drop and the technology of flash SSD controller innovates, high performance flash SSDs with affordable prices flourish in the storage market. Nevertheless, it is hard to expect that flash SSDs will replace harddisks completely as database storage. Instead, the approach to use flash SSD as a cache for harddisks would be more practical, and, in fact, several hybrid storage architectures for flash memory and harddisk have been suggested in the literature. In this paper, we propose a new approach to use flash SSD as an extended buffer for main buffer in database systems, which stores the pages replaced out from main buffer and returns the pages which are re-referenced in the upper buffer layer, improving the system performance drastically. In contrast to the existing approaches to use flash SSD as a cache in the lower storage layer, our approach, which uses flash SSD as an extended buffer in the upper host, can provide fast random read speed for the warm pages which are being replaced out from the limited main buffer. In fact, for all the pages which are missing from the main buffer in a real TPC-C trace, the hit ratio in the extended buffer could be more than 60%, and this supports our conjecture that our simple extended buffer approach could be very effective as a cache. In terms of performance/price, our extended buffer architecture outperforms two other alternative approaches with the same cost, 1) large main buffer and 2) more harddisks.

A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy (확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구)

  • Lee, Jeong-U;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

A New Snake Model for Tracking a Moving Target Using a Mobile Robot (로봇의 이동물체 추적을 위한 새로운 확장 스네이크 모델)

  • Han, Young-Joon;Hahn, Hern-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.7
    • /
    • pp.838-846
    • /
    • 2004
  • In the case where both a camera and a target are moving at the same time, the image background is successively changed, and the overlap with other moving objects is apt to be generated. The snake algorithms have been variously used in tracking the object, but it is difficult to be applied in the excessive overlap with other objects and the large bias between the snake and the target. To solve this problem, this paper presents an extended snake model. It includes an additional energy function which considers the temporal variation rate of the snake's area and a SSD algorithm which generates the template adaptive to the snake detected in the previous frame. The new energy function prevents the snake from over-shrinking or stretching and the SSD algorithm with adaptively changing template allows the prediction of the target's position in the next frame. The experimental results have shown that the proposed algorithm successfully tracks the target even when the target is temporarily occluded by other objects.

A Study on Bidirectional Stereo Matching Using Extended Kalman Filter (확장 칼만 필터를 이용한 양방향 스테레오 정합에 관한 연구)

  • 이철훈;설성욱;김효성
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.4
    • /
    • pp.389-394
    • /
    • 2002
  • In this paper, we propose a robust stereo matching algorithm using nonlinear extended Kalman filter. The proposed algorithm estimates disparity using nonlinear extended Kalman filter and compares left image to right image for obtained disparity. As this process is run iteratively, we get disparity only with a few search. And, we can get robust stereo matching results by comparing left image to right image using bilinear interpolation to consider influence of neighborhood pixel. We compared SSD algorithm which is widely used, in stereo matching method, to result of the proposed algorithm. As the result, the proposed algorithm has an outstanding matching performance.

High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution (흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델)

  • Choi, Dong-Rak;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • A mathematical model is presented for the calculation of the depth absorbed dose in water Phantom irradiated by high energy Photon beam (10MV X-ray), based on transport theory. The parameters of this model are obtained from the experimental values which were simulated by non-linear regression process method. The calculated absorbed dose distribution is extended to 3-D by using trial function from beam profile field sizes, SSD and depth in water phantom irradiated by high energy Photon beam. The calculated values using this model are in good agreement with the measured values.

  • PDF