• 제목/요약/키워드: exposured dose

검색결과 19건 처리시간 0.028초

방사선 감수성에 관한 연구 (6) 해충의 방사선감수성 (Studies of radiosensitivity (6) Radiosensitivity of insect pests)

  • 배대한
    • 한국응용곤충학회지
    • /
    • 제4권
    • /
    • pp.67-74
    • /
    • 1965
  • The work on the 'Studies of radiosensitivity' in Korea has been initiated since 1959 by the author at various institutions in home and foreign countries, and more than 20000 of plant materials in 73 varieties and 41 kinds are treated under varied conditions for the studies of radiosensitivity in plants. However, a study of the susceptibility to radiation in insect pests as well as their biological effects has not been previously reported in this country. During the year of 1964 and 1965, near 50000 of insects at the stages of adult, egg, larva and pupa in 14 different kinds are irradiated under acute X and gamma rays to investigate the behavior of growth and lethality after irradiation, and thrir general tolerances to radiations are compared by the kind of insects, stage of growth, radiation sources and exposured dosages. Through the experiments, it is shown that the lethality in most of insects are high as several kilo roentgens above and no significant effects on pupation. emergence, and oviposition in the treated generation at the dose of 3 Kr. below, but in the following generation , the rice stem borer for instance, no oviposition or decreased laying is observed from the dosages at 3 Kr. to 1 Kr., and the hatching was possible from 1.5 Kr. below of irradiated larvae although laying and hatching are seemed in normal. In general, the lethal dose $50\%$ of tested infect materials at the larval stage can he classified some what 60-80 Kr. for Pine caterpillar, Fall webworm, Camphor silk moth and their relatives, at 40-60 Kr. for Gypsy moth, Monley prominent and some relatives and at 20-30 Kr. for House fly, Rice weevil, Pine sawfly etc. Plant parasitic nematodes such as Hirschmannia and Paratylenchus shown very high resistance to radiation and the LD-50 is observed from 100 Kr. or above. A concept to evaluate the radiosensitivity in insects by taxological family line as a practical measure is not answerable yet, but it ran he solved within the near future through the continuing experiments.

  • PDF

131I 방사성 동위원소 치료에 따른 피폭 선량 연구 (The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy)

  • 장보석;유승만
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.653-659
    • /
    • 2019
  • 본 연구는 고용량 $^{131}I$ 치료 후 방사선원이 된 퇴원 환자로부터 나오는 방사선 피폭에 관해 외부 선량률을 측정하고, 그에 따른 피폭선량을 예측하는 것이 목적이다. 200 mCi 이상 고용량 $^{131}I$ 치료를 받은 30명의 환자에서 구리링 3개를 이용하여 환자로부터 거리 및 방위각에 따른 선량평가를 시행하였다. 정확한 방사선 계측을 위하여 GM 계측기를 이용하여 2명의 측정자가 방위각 8 포인트와 거리 변화를 주며 계측하였다. 측정값을 기반으로 3가지 예측 시뮬레이션을 설정하여 불특정 다수 일반인에 대한 피폭선량을 계산하였다. 1m 높이에서 방위각에 따른 외부 선량률이 가장 높은 부위는 0도이다. 거리에 따른 선량률은 거리별 방위각의 선량률 평균값을 사용하였다. 거리에 따른 외부 선량률의 최고치는 50, 100, 150 cm에서 각각 $214{\pm}16.5$, $59{\pm}9.1{\mu}Sv/h$, $38{\pm}5.8{\mu}Sv/h$ 이다. 고용량 $^{131}I$ 치료 환자가 대중교통을 이용해서 5시간 이동할 때 반경 50 cm 지점의 옆좌석에 안은 불특정 일반인이 받을 수 있는 피폭선량은 1.14 mSv이다. 소변 통(urin bag)을 착용한 퇴원환자로부터 100 cm 거리에서 4일 동안 간병인이 받을 수 있는 최대 피폭선량은 6.5 mSv이다. 퇴원 환자 귀가로 인해 7일 동안 150 cm 거리에서 보호자가 받을 수 있는 최대 피폭선량은 1.08 mSv이다. 개발된 예측 모델링으로 불특정 $^{131}I$ 치료 환자의 주변 일반인에게 적용하였을 때 연간 선량 한도를 단시간에 초과하는 수준이었다. 따라서 본 연구를 통해 현행 고용량 $^{131}I$ 치료 환자의 퇴원 후 주변의 일반인의 방호체계의 합리적인 가이드라인을 제시하는 데 도움을 줄 수 있을 것으로 사료된다.

64 다중채널 검출기 전산화단층촬영에서 환자고정자 재질에 대한 영상평가 (Image Evaluation for A Kind of Patient Fixing Pad in 64 Multi-Channel Detector Computed Tomograph)

  • 김기복;구은회
    • 한국융합학회논문지
    • /
    • 제7권1호
    • /
    • pp.89-95
    • /
    • 2016
  • 본 실험의 목적은 두부 팬텀 MDCT에서 5 종류의 환자고정자 패드를 이용하여 노이즈, 신호대 잡음비, 선량에 대하여 방사선감수성이 민감한 안와 와 기저핵 부위를 기준으로 영상의 질을 평가하고자 하였다. 영상의 노이즈는 AP가 가장 높게 나타났으며, 신호대 잡음비는 가장 낮게 나타났다. 환자고정자 재료 5(UP, RP, PP SP, AP) 종류 중 신호대 잡음비가 가장 높은 것은 UP 이었지만 RP, PP와 더불어 통계적 유의성이 없었고(p>0.05), UP, RP, PP와 SP, AP는 통계적 유의성이 있었다(p<0.05). 이러한 원인은 방사선을 입사했을 때 SOML의 기준선에 따른 검출기의 흡수선량정도와 각각의 재질의 성분에 따라 방사선 흡수선량이 다르기 때문에 노이즈 차이를 발생하게 된다. 안와 기저핵의 CTDIvol(mGy)와 DLP 값은 각각 56.95, 911.50로 환자고정자 재료에 따라 선량의 차이는 없었다. 결론적으로, 5 종류의 환자고정자 패드는 각각의 차이를 구별할 수 있었으며 SP, AP 보다 UP, RP, PP 사용은 임상적으로 유용한 정보를 제공할 수 있다.

국내 원전 종사자의 방사선량 : 2009-2013 (Radiation Exposure on Radiation Workers of Nuclear Power Plants in Korea : 2009-2013)

  • 임영기
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.162-167
    • /
    • 2015
  • 후쿠시마 원전 사고로 인한 우리나라 장기 전력수급정책에 대한 대중의 저항 및 불안감이 존재하고 있다. 고리 원전 1호기에 대한 정부의 영구정지 결정과 설계수명이 끝난 월성 원전 1호기의 계속운전 시행 반대, 고리 원전 인근 주민의 갑상선암 논란 등 원전 운영으로 인한 국내외 여건이 위기를 맞이하고 있다. 이러한 상황에서 원전운영능력과 안전은 여러 가지 지표들이 있지만, 원전의 방사선안전관리 능력, 특히 방사선피폭량을 중심으로 상세 분석과 논의가 필요하다. 분석대상과 방법으로는 최근 5년간 원전의 피폭 방사선량을 분석하고, 유관한 방사선 작업종사자군과 방사선 피폭량 추이를 비교 평가하였고, 세계 주요 원전 국의 개인당 연간 평균방사선량도 비교 분석하였다. 분석결과 방사선차폐와 방호조치등 총체적인 방사선량 저감화 계획과 연구를 통해 방사선피폭량을 저감하고 있음을 확인하였다. 연간선량한도한도인 50 mSv, 5년간 100 mSv를 초과한 방사선작업 종사자는 없었으며, 이는 방사선구역 출입시 자동화에 따른 출입제한과 관리선량 제한치를 연간선량한도의 60%미만으로 설정하는 등 다양한 방사선안전관리 체계를 확보하고 있음이 확인되었다. 원자로형별 운영형태에 따른 방사선피폭 유형은, 중수로 원전의 총 피폭대비 정상 운전시 방사선피폭비율이 경수로 원전보다 6.2 % 높게 나타났다. 이는 중수로 원전이 정상운전시 방사선피폭 작업이 많음을 확인하였다. 또한 세계원자력발전사업자협의회 성능평가지표(World Association of Nuclear Operators performance indicators, WANO PI)에 의하면, 2013년도 주요 원전보유국의 연간 호기당 집단선량은 우리나라가 527 man-mSv로 가장 우수한 실적을 보였으며, 세계평균치인 725 man-mSv의 73% 수준을 보이는 것으로 나타났다. 개인당 연간 방사선피폭량은 종사자의 약 80%가 일반인의 선량한도인 1 mSv 미만이며, 개인당 평균선량 역시 0.82 mSv로 매우 낮은 수준을 보였다. 유관 기관의 방사선작업 종사자와 비교해보면, 2013년 기준으로 방사선안전재단에 등록된 관련 업종 방사선작업 종사자의 개인당 평균선량은 1.07 mSv에 비해 77% 수준이며, 비파괴 검사기관 종사자의 개인 평균선량 3.87 mSv의 21% 수준을 보였다. 결론적으로 원전의 피폭 방사선량은 이상적으로 저감하는 추이를 보이고 있으나, 더 이상 낮추는 것은 한계가 있을 것으로 판단된다. 그러나 원전 주변 주민이 심리적인 불안감, 전원개발계획에서 원전의 비중을 감안할 때, 최적의 원전 상황을 평가하는 지표인 방사선안전관리 능력은 각종 통계를 기반으로 하는 정보 제시 및 총체적인 방사선량 저감화 추진이 필요할 것으로 판단된다.

토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가 (Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor)

  • 천금성;김창욱;김회남;허경훈;송진호;홍주영;정재용
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.97-103
    • /
    • 2010
  • 목 적: 상이한 치료장비를 이용하여 동일 부위에 중복하여 방사선치료 시 전산화치료계획장치간에 호환이 되지 않아 정상조직(Normal Tissue)의 총 흡수선량에 대한 평가의 한계점이 있다. 본 연구에서는 토모테라피(Tomotherapy)와 선형가속기(Linear accelerator)를 이용하여 동일 부위를 중복 치료할 때 환자가 받는 선량을 평가하고자 한다. 대상 및 방법: 인체모형팬텀(Anthropomorphic Phantom)을 대상으로 종양 및 정상조직을 묘사하여 선형가속기 치료계획장치 (Pinnacle 8.0: RTP)로 종양에 45 Gy 선량을 처방하고, 토모테라피 치료계획장치에서 종양에 15 Gy 선량을 처방하여 치료계획을 수립하였다. 토모테라피에서 수립된 치료계획을 통합가능 치료계획장치(Oncentra: RTP)에 전송한 후 동일한 조건으로 토모테라피 치료계획을 재현한 후 선형가속기에서 치료한 45 Gy를 합하여 총 선량 60 Gy의 치료계획을 구현하였다. 흡수선량 평가를 위해 두 개의 방사선 치료계획장치에서 얻어진 흡수선량(최소, 최대, 평균 선량) 및 관심 선량체적에 대해 서로 합(Total)한 값과 하나로 통합(Integration)하여 얻어진 값을 비교 분석하였다. 이를 바탕으로 본원에서 치료받은 환자 중 선형가속기와 토모테라피로 동일 부위에 치료 받은 5명(두경부 2명, 복부 1명, 골반부 2명)에 대하여 동일한 방법으로 종양 및 정상 조직의 흡수선량을 비교 분석하였다. 결 과: 인체모형팬텀에서 하나로 통합하여 얻어진 값과 서로 합한 값의 비교에서 최소선량은 비장(Spleen, 12.4%), 최대선량은 소장(Small bowl, 10.2%)과 척수(Spinal cord, 5.8%)에서 큰 차이를 나타냈다. 두경부 환자의 경우 최소선량은 구강(Oral cavity, 20.3%), 오른쪽 수정체(Rt lens, 7.7%)에서 큰 차이를 나타냈으며, 최대선량은 척수(22.5%), 뇌간(Brain stem; 12.0%), 시 신경교차(Optic chiasm; 8.9%), 오른쪽 수정체(11.5%), 하악골(Mandible bone, 8.1%), 뇌하수체(Pituitary gland, 6.2%)에서 뚜렷한 차이가 나타났다. 복부 환자의 경우 최대선량은 왼쪽 신장(Lt kidney, 20.3%), 위(Stomach, 8.1%)에서 큰 차이가 나타났고, 골반 부위 환자의 경우 최소 선량은 방광(Bladder, 15.2%), 최대선량은 소장(5.6%), 방광(5.5%)에서 큰 차이를 나타냈다. 또한 동일 부위 방사선치료계획 시 정량화되지 못했던 신장의 20 Gy를 받은 체적($V_{20}$)에서 37%, 간(Liver)의 25 Gy를 받은 체적($V_{25}$)에서 23%가 선량체적히스토그램(DVH)에서 나타났다. 결 론: 하나로 통합하여 얻어진 값과 서로 합한 값의 비교에서 최소선량은 높게, 최대선량은 낮게, 평균선량은 동일한 값으로 나타났다. 또한 관심장기의 선량 체적($V_{20}$)보다 낮은 선량을 처방했을 때 구현하지 못했던 종양 및 정상조직의 흡수선량에 대하여 평가를 할 수 있었다. 향후 상이한 치료 장치들을 이용한 동일 부위 치료 시 흡수선량의 통합 평가뿐만 아닌 정확한 선량분포를 구현할 수 있는 치료계획장치의 개발이 요구되어지며, 이에 관련된 연구가 진행되어져야 한다.

  • PDF

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석 (Correlation analysis of radiation therapy position and dose factors for left breast cancer)

  • 전재완;박철우;홍종수;진성진;강정훈
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.37-48
    • /
    • 2017
  • 목 적: 방사선치료의 가장 기본적인 조건은 정상조직의 불필요한 피폭을 방지하는 것이다. 유방암의 경우는 폐와 심장에 조사되는 선량이 중요하게 평가되는 인자이다. 따라서 유방암 방사선치료 자세에 따른 정상조직에 조사되는 선량을 비교하고 그 연관성을 상관관계 분석을 통하여 결과를 확인하여 보다 효과적인 유방암 방사선 치료방법을 모색하고자 한다. 대상 및 방법: 본원을 내원한 좌측 유방암 환자 30명을 대상으로 Supine, Prone Position에서 CT image를 획득하였다. Eclipse Treatment Planning System(Version 11, USA)을 이용하여 전산화치료계획을 수립하였다. DVH(Dose Volume Histogram)을 통해 Position 별로 정상조직에 조사된 선량을 비교하였다. 그 결과를 바탕으로 SPSS(Version 18)을 이용하여 각 정상조직의 선량인자를 통계분석하고 항목 간 상관관계 분석 및 독립표본 t-test를 통하여 그 연관성을 알아보았다. 그리고 MIRADA RTx(Version Advanced 1.6, UK)를 이용하여 HI(Homogeneity Index)와 CI(Conformity Index)를 Supine, Prone Position에서 값을 구하고 비교하였다. 결 과: 유방암의 전산화치료계획의 결과 폐의 경우는 Supine Position에서 V20은 $16.5{\pm}2.6%$, V30은 $13.8{\pm}2.2%$, Mean dose는 $779.1{\pm}135.9cGy$(Absolute value)를 보였다. Prone Position은 위 순서대로 $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$를 보였다. Prone Position이 전반적으로 낮은 선량을 나타내었고 평균선량 537.7 cGy가 더 적게 폐에 조사되었다. 심장의 경우에는 Supine, Prone 순서대로 V30은 $8.1{\pm}2.6%$, $5.1{\pm}2.5%$, Mean dose는 $594.9{\pm}225.3cGy$, $408{\pm}183.6cGy$를 보였다. Prone Position에서 평균선량 182.6 cGy가 더 적게 조사된다는 것을 확인하였다. 통계분석 결과 신뢰도 분석지표인 Cronbach's Alpha value는 0.563이였고 변수간의 상관관계분석 결과 치료자세와 폐의 선량평가인자는 대략 0.89 이상으로 그 상관관계가 높았다. 반면 심장의 경우는 V30은 0.488, Mean dose는 0.418로 상관관계가 다소 적었다. 마지막으로 독립표본 t-test 결과 치료자세와 폐, 심장의 선량평가인자가 신뢰수준 99 %에서 모두 유의하게 나타났다($p-value{\leq}0.05$). 결 론: 현재 방사선치료는 최첨단 선형가속기와 다양화된 전산화치료계획 기술이 개발되고 있다. 이 발전의 기본전제 조건은 PTV(Planning Target Volume) 주위의 정상조직 보호라고 생각한다. 물론 유방암 환자를 Prone Position에서 치료하면 Set-up의 재현성 문제와 다소 많은 시간이 소요되지만 이 실험결과에서 보듯이 Prone Position에서 폐와 심장에 들어가는 선량을 줄일 수 있으며 그 연관관계도 의미가 있다는 것을 확인하였다. 결론적으로 Prone Position에서 충분한 치료시간을 확보하고 정확한 치료부위 확인이 이루어진다면 환자에게 보다 좋은 방사선치료를 제공할 수 있다고 생각된다.

  • PDF

이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증 (Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design)

  • 강상식;허승욱;최일홍;전제훈;양승우;김교태;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.547-553
    • /
    • 2017
  • 현재 의료분야에서는 방사선 차폐체로서 납(Pb)이 널리 쓰이고 있다. 하지만 납은 무게가 매우 무거워 납치마 등의 방호복은 장시간 착용이 어려우며, 인체에 치명적인 납 중독의 위험이 상시 가지고 있다는 문제점을 가지고 있다. 이러한 문제점을 해결하고자 납을 대체 할 수 있는 물질에 대한 많은 연구가 진행되고 있다. 현재 납의 대체물질로써 대표적인 바륨(Ba)과 요오드(I) 등은 우수한 차폐능을 가지고 있지만, 30keV 근처의 에너지 영역에서 특성 X선을 방출하는 특성을 가지고 있다. 환자나 방사선 종사자의 경우 차폐체를 인체에 접촉하고 있는 경우가 많으므로 차폐체에서 발생되는 특성 X선이 인체에 직접 조사되어 방사선 피폭을 증가시킬 위험이 매우 높다. 본 연구에서는 바륨(Ba)과 요오드(I)등에서 발생되는 특성 X선을 제거하기에 적절한 이중구조 차폐체를 방사선 수송코드 중 하나인 FLUKA 수송코드를 개발하여 선행연구로서 진행된 MCNPX 시뮬레이션과 비교 분석하여 이중구조 차폐체의 차폐율에 대한 신뢰성을 검증하고자 하였다. MCNPX와 FLUKA를 이용하여 황산바륨($BaSO_4$)과 산화비스무스($Bi_2O_3$)로 이루어진 다양한 두께조합의 이중구조 차폐체를 설계하였으며, IEC61331-1에 제시된 모식도를 기하학적으로 동일하게 시뮬레이션 상에 구현하였다. 또한, 120 kVp의 연속 X선 스펙트럼에 대한 차폐체의 투과스펙트럼과 흡수선량을 납과 비교 평가하였다. 평가결과, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$$0.1mm-BaSO_4/0.5mm-Bi_2O_3$ 구조에서는 33 keV와 37 keV의 특성 X선을 모두 흡수하였으며, 90 keV 이상의 고에너지 X선에 대해서도 납과 거의 유사한 차폐효율을 보였다. 또한, FLUKA의 수송코드는 33 keV 이하에서는 cut-off 가 발생하여 저에너지 X선 광자에 대한 전산모사에 제약이 있지만, 40 keV 이상의 고에너지 영역에서 MCNPX와의 상대오차가 6 % 이내로 신뢰성이 매우 우수하다는 것을 확인할 수 있었다.

임신 중 수은을 섭취한 CD-1 마우스 태아의 성장발육과 기형발생에 미친 셀레늄의 효과 (The effects of selenium on fetal growth and development in CD-1 mice exposed with mercury for the gestation period)

  • 김진석;이상목;최석화;이원창
    • 대한수의학회지
    • /
    • 제34권2호
    • /
    • pp.361-368
    • /
    • 1994
  • 기형발생을 나타내는 수은의 독성에 대하여는 이미 보고된 바 있으나 임신중에 폭로된 수은의 독작용을 완화시키거나 치료할 수 있는 제재들에 대하여는 별로 알려진 바가 없다. 수은에 대한 셀레늄의 치료적인 상호작용에 대하여는 이미 보고된바 있으나 태아에 대한 효과를 평가하기 위하여 이 연구는 임신한 CD-1마우스에 20ppm 농도의 유기수은을 음수를 통하여 투여한후 동시에 sodium selenite(체중 kg당 0.1mg, 0.2mg, 0.3mg, 피하주사) 또는 BAL(체중 kg당 5.0mg, 피하주사)을 임신 6일째부터 15일 사이에 단독 또는 병용 투여한 후 임신 18일째에 제왕절개술을 실시하였다. 수은단독 투여군에서는 태아의 체중 및 두부-둔부의 길이 그리고 태반의 무게가 투여를 하지 않은 대조군에 비하여 유의성있게 감소하였고 태아의 사망/재흡수 발생과 기형발생(특히 구개열)이 현저히 증가하였다. 셀레늄과 BAL의 단독 또는 병용투여는 수은에 의하여 발생된 태아에 대한 독작용을 억제하거나 감소시키고 기형발생 역시 유의성있게 감소시켰으나 투여용량 그리고 투여계획과는 특이한 상관관계가 발견되지 않았다. 모체의 수은중독 결과로 보이는 모체의 음수, 사료섭취량과 모체의 상대적 기관(간장, 신장, 비장) 무게의 감소도 셀레늄과 BAL의 투여로 증가되었다. 이 연구 결과는 세레늄을 단독 또는 BAL과 같은 기존치료제와 함께 투여할 경우 수은에 의한 기형발생이나 모체의 아급성 중독 증세를 감소시키거나 완화시킬수 있는 효과가 있음을 보여주고 있다.

  • PDF