• Title/Summary/Keyword: exposure temperature

Search Result 1,390, Processing Time 0.037 seconds

The Canopy Transparency Coating Study of Cockpit Temperature Effect Verification (조종실 온도 영향성 검증을 위한 캐노피 투명체 코팅 연구)

  • Nam, Yongseog;Kim, Taehwan;Kim, Yunhi;Woo, Seongjo;Kim, Myungho
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.42-45
    • /
    • 2008
  • Under the non-operating exposure condition in the hot area, the T-50 cockpit temperature is expected over the requirement according to T-50 environmental criteria. So it is necessary to protect the cockpit from the high temperature condition during the non-operating exposure because the high temperature of the cockpit may result in the cockpit equipment malfunction. In this study, the transparency coating is selected as the method for protecting the cockpit from the high temperature exposure and analyzed the effect on the cockpit heat load attenuation. Some kinds of cockpit coating were reviewed and selected and the analysis was performed about the effect before and after coating application under 1% hot day condition based on the T-50 FSD hot soaking test data. The result of analysis show transparency coating is so effective to attenuate the heat load of T-50 cockpit.

  • PDF

Characteristics and Health Status of Outdoor Workers Exposed to High Temperature (우리나라 고온 노출 야외작업자의 특성과 건강수준)

  • Lee, Bokim
    • Korean Journal of Occupational Health Nursing
    • /
    • v.31 no.2
    • /
    • pp.95-103
    • /
    • 2022
  • Purpose: This study aims to identify general, workplace, and health-related characteristics of outdoor workers exposed to high temperatures, and to compare the risk of disease according to outdoor high temperature exposure. Methods: This secondary analysis study used the 5th Korean Working Conditions Survey (2017) to identify 4,915 outdoor workers exposed to high temperatures. Results: Outdoor workers exposed to high temperatures were mostly male, elderly, less educated, and daily contract workers. Most of them were engaged in agriculture, forestry and fishing, and construction industries. About 40~50% of them complained of musculoskeletal pain and overall fatigue. The results showed that high temperature exposure increased the risk of illness (hearing problem, skin problem, backache, muscular pains in upper and lower limbs, headache/eyestrain, injuries, depression, and overall fatigue) among workers. Conclusion: High temperature exposure might increase the risk of illness among workers. The results of this study demonstrated that the outdoor workers should be protected from high temperatures.

A Study on Temperature and Tensile Load Analysis of Invar by Flame Exposure on Overhead Transmission Lines (화염노출에 의한 송전선로 인바 강심의 온도 및 인장하중 분석에 관한 연구)

  • Shin, Koo-Yong;Jung, Chae-Kyun;Lee, Sang-Yun;Kang, Ji-Won;Lee, Dong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1895-1901
    • /
    • 2009
  • This paper describes the conductor temperature and tensile load analysis of invar by flame exposure on STACIR(Super Thermal-resistance Aluminium-alloy Conductors Reinforced) overhead transmission line based on real fault phenomena. Firstly, short-circuit fault by flame exposure is analysed by EMTP/ATP simulation, then the cutting causes of Al layer are also discussed. And then, the conductor temperature is calculated based on IEC 60949 according to 3 kinds of materials including invar, Al conductor and ACSR when same load current respectively flows in 3 kinds of material, they are compared each other. Finally, the tensile load tests are performed with various samples including new invar, used invar for a long time and invar exposed flame.

Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry (홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.530-535
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at $Ra = 6.35{\times}10^6$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful for analyzing the temperature field variations of unsteady thermal fluid flows.

  • PDF

Residual Stress on Concentric Laminated Fibrous Al2O3-ZrO2 Composites on Prolonged High Temperature Exposure

  • Sarkar, Swapan Kumar;Lee, Byong Taek
    • Korean Journal of Materials Research
    • /
    • v.23 no.9
    • /
    • pp.531-536
    • /
    • 2013
  • This paper investigates the effect of prolonged high temperature exposure on concentric laminated $Al_2O_3-ZrO_2$ composites. An ultrafine scale microstructure with a cellular 7 layer concentric lamination with unidirectional alignment was fabricated by a multi-pass extrusion method. Each laminate in the microstructure was $2-3{\mu}m$ thick. An alternate lamina was composed of 75%$Al_2O_3$-(25%m-$ZrO_2$) and t-$ZrO_2$ ceramics. The composite was sintered at $1500^{\circ}C$ and subjected to $1450^{\circ}C$ temperature for 24 hours to 72 hours. We investigated the effect of long time high temperature exposure on the generation of residual stress and grain growth and their effect on the overall stability of the composites. The residual stress development and its subsequent effect on the microstructure with the edge cracking behavior mechanism were investigated. The residual stress in the concentric laminated microstructure causes extensive micro cracks in the t-$ZrO_2$ layer, despite the very thin laminate thickness. The material properties like Vickers hardness and fracture toughness were measured and evaluated along with the microstructure of the composites with prolonged high temperature exposure.

Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry (홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1624-1631
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at Ra = 6.35 $\times$ 10$^{6}$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful fur analyzing the temperature field variations of unsteady thermal fluid flows.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • v.5 no.5
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.

Ecophysiological responses of Quercus gilva, endangered species and Q. glauca to long-term exposure to elevated CO2 concentration and temperature

  • Kim, Hae-Ran;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • v.35 no.3
    • /
    • pp.203-212
    • /
    • 2012
  • The physiological effects of elevated $CO_2$ concentration and temperature were examined for Quercus gilva and Q. glauca grown under control (ambient $CO_2$ and temperature) and treatment (elevated $CO_2$ and temperature) conditions for 39 months. The objective of the study was to measure the long-term responses, in physiological parameters, of two oaks species exposed to elevated $CO_2$ and temperature. The photosynthetic rate of Q. gilva was found to be decreased, but that of Q. glauca was not significantly affected, after long-term exposure to elevated $CO_2$ and temperature. Stomatal conductance of Q. glauca was reduced by 21.7%, but that of Q. gilva was not significantly affected, by long-term exposure to $CO_2$ and temperature. However, the transpiration rate of the two oak species decreased. Water use efficiency of Q. gilva was not significantly affected by elevated $CO_2$ and temperature, while that of Q. glauca was increased by 56.6%. The leaves of Q. gilva grown under treatment conditions had an increased C:N ratio due to their reduced nitrogen content, while those of Q. glauca were not significantly affected by long-term exposure to elevated $CO_2$ and temperature. These results suggest that the long-term responses to elevated $CO_2$ and temperature between Q. gilva and Q. glauca are different, and that Q. gilva, the endangered species, is more sensitive to elevated $CO_2$ and temperature than Q. glauca.

Pulmonary and Cutaneous Evaporative Water Losses in Sahiwal and Sahiwal × Holstein Cattle During Solar Exposure

  • Aggarwal, Anjuli;Upadhyay, R.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.318-323
    • /
    • 1997
  • In order to assess the effect of solar exposure on pulmonary functions and evaporative losses from skin and pulmonary surfaces, in six healthy Sahiwal (S) and six Sahiwal ${\times}$ Holstein ($S{\times}H$) cattle were exposed to direct sun during summer. Breed differences were observed during exposure. Increase in sweating rate was higher in crossbreds (222%) than in Sahiwal (125%). Pre-exposure (ambient temperature, $32.6{\pm}0.85^\circ}C$, solar radiation, $0.9cal\;cm^{-2}min^{-1}$) evaporative loss from skin accounted for about 90% of the losses and remaining losses were contributed by pulmonary surfaces in Sahiwal. The contribution of evaporation through skin increased to 92% (ambient temperature $39.4{\pm}0.68^\circ}C$, solar radiation, $1.35cal\;cm^{-2}min^{-1}$). In crossbreds 80% of the evaporative losses were through skin before exposure which increased to 87% after exposure to solar radiations. Rectal temperature increase was higher in crossbreds ($1.5^{\circ}C$) than in Sahiwal ($0.8^{\circ}C$). With the increase in pulmonary evaporative losses, respiratory frequency increased to 2 fold in Sahiwal and pulmonary ventilation increased 1.6 times the resting value in Sahiwal due to solar exposure. In $S{\times}H$ crossbreds the respiratory frequency increased 3.5 times and pulmonary ventilation increased only to 1.8 times due to decrease in tidal volume. There was about 2 fold increase in alveolar ventilation in both the breeds, the increase in dead space ventilation was more in crossbreds than in Sahiwal. Behavioral symptoms exhibited by animals after exposure were profuse salivation, open mouth panting, tongue protrusion and general restlessness.

Occupational Exposure to Refractory Ceramic Fibers in the Semiconductor Scrubber Manufacturing Industry

  • Song, Seungwhan;Kim, Sunju;Kim, Donghyeon;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.357-363
    • /
    • 2022
  • Background: Refractory ceramic fibers (RCFs) are a suspected carcinogen but have been widely used as insulations. Depending on the temperature, RCFs can transform into crystalline SiO2, which is a carcinogen that can be present in the air during bulk RCF handling. This study analyzed the physicochemical and morphological characteristics of RCFs at high temperatures and determined the exposure levels during the semiconductor scrubber maintenance. Methods: Sampling was conducted at a company that manufactures semiconductor scrubbers using RCFs as insulation. Bulk RCF samples were collected both before and after exposure to a scrubber temperature of 700℃. Airborne RCFs were collected during scrubber maintenance, and their characteristics were analyzed using microscopes. Results: The components of bulk RCFs were SiO2 and Al2O3, having an amorphous structure. Airborne RCFs were morphologically different from bulk RCFs in size, which could negatively affect maintenance workers' health. 58% of airborne RCFs correspond to the size of thoracic and respirable fibers. RCFs did not crystallize at high temperatures. The exposure caused by airborne RCFs during the scrubber frame assembly and insulation replacement was higher than the occupational exposure limit. Conclusion: Workers conducting insulation replacement are likely exposed to airborne RCFs above safe exposure limits. As RCFs are suspected carcinogens, this exposure should be minimized through prevention and precautionary procedures.