• 제목/요약/키워드: exposure pattern

검색결과 453건 처리시간 0.027초

평일 시간활동패턴을 활용한 도시 인구의 유사노출집단 분류 (Determination of Similar Exposure Groups Using Weekday Time Activity Patterns of Urban Populations)

  • Hwang, Yunhyung;Lee, Kiyoung;Yoon, Chung-Sik;Yang, Wonho;Yu, Seungdo;Kim, Guenbae
    • 한국환경보건학회지
    • /
    • 제42권6호
    • /
    • pp.353-364
    • /
    • 2016
  • Objectives: Determining the time activity patterns of urban populations is critical when performing an exposure assessment. The purposes of this study were to classify urban populations in Korea by their time activity patterns and to identify factors that influence these patterns. Methods: The time activity patterns of 31,634 and 20,263 individuals were obtained from two national databases collected in 2004 and 2009, respectively. The two largest metropolitan cities in Korea, Seoul and Busan, were selected for this analysis. For each city, multivariate linear regressions were performed to determine factors affecting the time spent in a residence and in transit. We also used cluster analysis to classify each urban population by activity pattern. Results: Nine distinctive activity patterns were identified in the Seoul and Busan populations, respectively, and the resulting classified population groups had specific characteristics. The identified patterns were similar for Seoul and Busan. The most significant factors affecting time spent in a residence were employment status, age, marriage status, education, and gender. Gender, education, employment status, and monthly income were significant factors affecting time spent in transit. Conclusion: These results indicate that, in addition to region, exposure scientists in Korea should consider classifying populations based on age, gender, and occupation.

Computed Radiography의 영상특성에 관한 연구 (Study of Image Properties for Computed Radiography)

  • 류기현;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

Application of a Microbial Toxicity Assay for Monitoring Treatment Efficiency of Pentachlorophenol in Water using UV Photolysis and $TiO_2$ Photocatalysis

  • Kim, Jung-Kon;Cho, Il-Hyung;Zoh, Kyung-Duk;Choi, Kyung-Ho
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.146-150
    • /
    • 2004
  • Degradation efficiency of pentachlorophenol (PCP) by using direct UV photolysis and $TiO_2$ photocatalysis was evaluated with both chemical analyses and acute toxicity assessment employing luminescent bacteria Vibrio fischeri. PCP was chosen as a target compound in this study because of its wide application as fungicide, bactericide, insecticide and wood preservative in agriculture and many industries, in addition to its well-known environmental consequences. The acute toxicity to the microbe was reduced by >60% when applying UV alone, and was completely removed when treated with $UV-TiO_2$ combinations. Toxicity reduction pattern determined with the Microtox Assay generally corresponds with the chemistry data: However, it should be noted that toxicity was greater than expected by the chemistry data. Formation of TCBQ, a toxic byprodut, could not explain observed microbial toxicity. These observations are probably due to the presence of unidentified toxic PCP byproducts, which may include polychlorinated dibenzodioxins and polychlorinated dibenzofurans. When Microtox results were compared between different exposure time, i.e.,5 min and 15 min, an interesting pattern was noted with $UVA-\;TiO_2$ treatment. While no microbial toxicity was observed with 5 min exposure, an EC50 value of 45.4% was estimated with 15 min exposure, which was not observed in $UVB-\;TiO_2$ exposure. This result may suggest the presence of unidentified toxic degradation products generated in the later stage of treatment. Based on this study, $TiO_2$ photocatalyst, together with UVB photolysis could improve the removal of both PCP and its toxic derivatives in more efficient way. The Microtox Assay is promising and economical method for monitoring efficiency of wastewater treatment processes.

  • PDF

DMD를 이용한 마스크리스 리소그래피 시스템의 고해상도 구현을 위한 다중 빔 에너지 분석에 관한 연구 (A Study on the Analysis of Multi-beam Energy for High Resolution with Maskless Lithography System Using DMD)

  • 김종수;신봉철;조용규;조명우;이수진
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.829-834
    • /
    • 2011
  • 고 집적 회로의 제작에 있어서 노광 공정은 가장 중요한 기술로 주로 마스크 방식의 노광 방법을 사용하지만 다품종 소량 생산 및 주기적인 제품 변화에 있어서 효율적이지 못하기 때문에 마스크리스 리소그래피 기술이 노광공정에서 각광받고 있다. 본 연구에서는 DMD를 이용한 마스크리스 리소그래피에 있어 다중 레이저 빔의 에너지와 중첩도와의 연관성을 시뮬레이션을 통해 분석하였다. 시뮬레이션을 통해 최적의 스캔 라인 간격을 제시하였고, LDI 시스템을 이용한 노광 실험을 통해 미세 페턴의 정밀도를 향상시킬 수 있었다.

FPD 공정을 위한 램프하우스 열전달 특성 연구

  • 김태안;서원호;김준현;김윤제
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 추계학술대회 발표 논문집
    • /
    • pp.132-137
    • /
    • 2006
  • With the help of the development of digital-multimedia in the middle of 1990's, FDP(Flat Panel Display) had attracted considerable attention. Collimation proximity exposure system that transfers the pattern on wafer or glass exactly using mask and light with appropriate wavelength is core process in semiconductor and liquid display element. The performances of resolution required in precision exposure system are evaluated by resolving power, depth of focus and storage area. Most of development has targeted on these three factors. The optical design including lamp house has played an important role on the performance of exposure process. In this study, we evaluate the cooling system, concerning on exposure device with mercury lamp among the kernel equipment for the production of LCD, to prevent the instability of lighting due to long term accumulation of excessive heating inside the lamp house. Numerical analysis is conducted on full-scale model. The characteristics of three-dimensional flow, pressure and temperature distribution on exposure system are graphically depicted to estimate the whole cooling system for lamp house and to establish the design criteria.

  • PDF

다중노광 나노구 리소그라피를 이용한 쌍-광자결정 어레이 제작 (Fabrication of Pair-Photonic Crystal Arrays using Multiple-Exposure Nanosphere Lithography)

  • 여종빈;한광민;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.245-249
    • /
    • 2010
  • Two dimensional(2D) pair-photonic crystals (pair-PCs) have been fabricated by a multiple-exposure nanosphere lithography (MENSL) method using the self-assembled nanospheres as lens-mask patterns and the collimated laser beam as a multiple-exposing source. The arrays of the 2D pair-PCs exhibited variable lattice structures and shape the control of rotating angle (${\Theta}$), tilting angle (${\gamma}$) and the exposure conditions. In addition, the base period or filling factor of pair-PCs as well as their shapes could be changed by experimental conditions and nanosphere size. A 1.18-${\mu}m$-thick resist was spincoated on Si substrate and the multiple exposure was carried out at change of ${\gamma}$ and ${\Theta}$. Images of prepared 2D pair-PCs were observed by SEM. We believe that the MENSL method is a suitable useful tool to realize the pair-periodic arrays of large area.

공간분석 기법을 이용한 대기오염 개인노출추정 방안 소개 및 적용의 사례 (Prediction Approaches of Personal Exposure from Ambient Air Pollution Using Spatial Analysis: A Pilot Study Using Ulsan Cohort Data)

  • 손지영;김윤신;조용성;이종태
    • 한국대기환경학회지
    • /
    • 제25권4호
    • /
    • pp.339-346
    • /
    • 2009
  • The objectives of this study were to introduce spatial interpolation methods which have been applied in recent papers, to apply three methods (nearest monitor, inverse distance weighting, kriging) to domestic data (Ulsan cohort) as an example of estimating the personal exposure levels. We predicted the personal exposure estimates of 2,102 participants in Ulsan cohort using spatial interpolation methods based on information of their residential address. We found that there was a similar tendency among the estimates of each method. The correlation coefficients between predictions from pairs of interpolation methods (except for the correlation coefficient between nearest montitor and kriging of CO and $SO_2$) were generally high (r=0.84 to 0.96). Even if there are some limitations such as location and density of monitoring station, spatial interpolation methods can reflect spatial aspects of air pollutant and spatial heterogeneity in individual level so that they provide more accurate estimates than monitor data alone. But they may still result in misclassification of exposure. To minimize misclassification for better estimates, we need to consider individual characteristics such as daily activity pattern.

유치원 여교사(女敎師)와 전업주부(主婦)의 이산화질소 노출비교 및 평가 (Comparative Study on Nitrogen Dioxide Exposure of Female Teachers from Kindergarten and House Wives)

  • 양원호;김순복;배현주;이영미;정문호;정문식
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2001
  • Since most people spend over 80% of their time indoor, indoor air quality tends to be the dominant contributor to personal exposure. In this study, indoor and outdoor $NO_2$concentrations were measured and compared with simultaneously personal exposures of 27 house-wives and female workers of kindergarten. Time activity pattern and house characteristics were used to determine the effects of these factors on personal exposure. Since house-wives student spent most their times in indoor with mean of 89.8%, their $NO_2$ exposure was associated with indoor $NO_2$ level(r= 0.92) rather than outdoor $NO_2$ level(r= 0.87). female workers were also associated with indoor $NO_2$ level(r= 0.70) though sample number were small. Using time-weighted average model, $NO_2$ exposures of house-wives were estimated by $NO_2$ measurements in indoor home and outdoor home levels. Estimated $NO_2$ personal exposures were significantly correlated with measured $NO_2$ personal exposures (r= 0.90). These results might mean that air pollutants exposure of old and feeble persons, and infants could be estimated by measuring concentrations of indoor home.

  • PDF

$PM_{10}$개인노출과 공중이용시설내 농도에 관한 연구 (Personal Exposure to $PM_{10}$ and its Concentration in Public Facilities)

  • 김만구;정영림;임양석
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.185-190
    • /
    • 1998
  • $PM_{10}$ concentrations were measured In underground stores located In 4 major cities, Chunchon, Wonju, Donghae and Sockcho, In Kangwon-Do using scattering light Integated type digital dust indicator. Per- sonal exposure to $PM_{10}$ for two women(housekeeper and gaduate students and a man(undergraduate student) were measured also. The dimensional conversion factors for mass concentrations(K) showed some difference among un- derground stores which were 2.0, 2.7, 3.4, 2.6 mg/$m^2$.CPM In chunchon, Wonju, Donghae and Sockcho, respectively. Average PMlo concentrations at underground stores were 178mg/$m^2$ in Chunchon, 141mg$m^2$ in Wonju, 125 mg/$m^2$ Donghe and 59mg/$m^2$) Sockcho. The portion of $PM_{10}$ In total suspended particles was about 50~60% as deight The exposure of graduate student, housekeeper and undergraduate to $PM_{10}$ during 12 hours were 1004. 3 (mg/$m^2$) .hr, 907.0 (mg/$m^2$) hr and 691.2 (mg/$m^2$) hr, respectively. Personal exposure to $PM_{10}$ showed very different according to heP activity pattern and they had more than 90 % of their $PM_{10}$ exposure at Indoor environment.

  • PDF

Expression Pattern of Phospholipid Hydroperoxide Glutathione Peroxidase Gene in the Male Reproductive System of Sprague-Dawley Rats Exposed to 17 $\beta$-estradiol

  • In, Chang-Hoon;Nam, Sang-Yoon;Kang, Jong-Koo
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2001년도 International Symposium on Signal transduction in Toxicology
    • /
    • pp.164-164
    • /
    • 2001
  • This study investigated expression pattern of PHGPx gene in male rat reproductive organs exposed to 17$\beta$-estradiol. First, in view of quantitative change, the exposure to 17$\beta$-estradiol for 1 week increased PHGPx mRNA level in testis and prostate. PHGPx mRNA level in epididymis decreased weakly as compared to control group.(omitted)

  • PDF