• Title/Summary/Keyword: exposure limit

Search Result 559, Processing Time 0.031 seconds

Pd nanoparticles on poly(amidoamine) dendrimers modified single-walled carbon nanotubes as highly sensitive hydrogen gas sensors

  • Lee, Jun-Min;Lee, Eun-Song-Yi;Jeon, Kye-Jin;Ju, Seong-Hwa;Jung, Yeong-Ri;Kim, Sung-Jin;Lee, Woo-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.93-93
    • /
    • 2009
  • In order to overcome the lack of reactivity with hydrogen gas ($H_2$) and utilize unique properties of Carbon Nano Tubes (CNTs) for the application to hydrogen sensors, there have been intensive works on the surface functionalization of CNTs with various types of nanoparticles including Pd. In the present work, we have investigated the effect of dendrimers and Pd nanoparticles to the hydrogen sensing properties of CNTs by comparing three types of samples: Pd/SWNTs (Sample I), Pd/dendrimer/SWNTs (Sample II) and heat-treated Pd/dendrimers/SWNTs (Sample III). As a result of IV measurement under the $H_2$ and air, sample I was found to have a high sensitivity (25%) to $H_2$, but to have a very slow response time (324 s) and recovery rate. On the other hand, Sample II was found to show much faster response time (3 s) and good recovery rate but lower sensitivity (8.6%) than Sample I which is due to induced dipole moments in the dendrimers. Interestingly, Sample III showed both fast response time (7 s) and high sensitivity (25%), indicating that the pyrolysis of the dendrimers during heat treatment which reduce the distance between the surface of the SWNTs and the functionalized Pd nanoparticles plays a key role in improving the sensitivity. The pyrolysis of the dendrimers in Pd nanoparticle-dendrimer-SWNTs was found to enable a significant electrical conductance modulation upon exposure to extremely low concentrations (10 ppm) of $H_2$ in air. Our results demonstrate that the Pd Nanoparticle-Grafted Single-Walled Carbon Nanotubes(SWNTs) with Dendrimers can be used to detect hydrogen, makingoutstanding properties such as fast response, and recovery time, high sensitivity, low detection limit at room temperature compared with other types of hydrogen sensors.

  • PDF

Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$ ($^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준)

  • Chie, Eui-Kyu;Lee, Myung-Mook;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

  • PDF

Indicating the Problem of Shielding Design and the Way of Estimating Radiation Leakage for CT Rooms located through Survey of Radiation Leakage : in the case of Busan and Gyung-nam Area (방사선 누설선량 조사를 통한 방어시설과 누설선량 평가방법에 대한 문제점 연구 : 부산, 경남 지역 CT실을 중심으로)

  • Yang, Won Seok;Choi, Jun-Hyeok;Shin, Woon-Jae;Min, Byung-In
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.768-777
    • /
    • 2013
  • The purpose of this study is to minimize radiation exposure to the workers and public members during CT examination. The objects are seven of the CT rooms in university hospitals and four of the CT rooms in clinics located in Busan and Gyung-nam area. The places of measurement for radiation leakage are 1) 3 m above the ground of shielding wall in the control room 2) particular space in the control room 3) worker's gate in the control room 4) the patient gate. Its values were calculated maximum leakage radiation per week(MLRW). As a result, the worker's gate of M clinic displayed the highest dose. When it was calculated by MLRW in classic method, it showed 1) $5.97{\pm}0.23$, 2) $0.50{\pm}0.02$, 3) $10.00{\pm}0.11$, 4) $2.37{\pm}0.47$ mR/week. All of them did not exceed limit for maximum permissible dose per week(MPDW). However, When MLRW of M clinic was calculated by empirical method, its value displayed $118.31{\pm}17.72$ mR/week.(MPDW>100 mR/week). Radiation leakage influenced in the control room(p<0.05). Therefore, The way of calculating MLRW must be developed and shielding wall in control room is designed 3 m above the ground for reducing dangerous of leakage radiation.

Determination of Hg (II) Ion at a Chemically Modified Carbon Paste Electrode Containing L-Sparteine (L-Sparteine 수식전극을 사용한 Hg (II) 이온의 정량)

  • Euh Duck Jeong;Mi-Sook Won;Yoon-Bo Shim
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.545-552
    • /
    • 1991
  • A mercury ion-sensitive carbon-paste electrode (CPE) was constructed with l-sparteine. Mercury (II) ion was chemically deposited by the complexation with l-sparteine onto the CPE. The surface of CPEs was characterized by cyclic voltammetry and anodic stripping voltammetry in an acetate buffer solution, separately. Exposure of CPEs to acid solution could regenerate surface and reuse it for deposition. In 5 deposition/measurement/regeneration cycle, the response was reproducible and in licnear up to $2.0\;{\times}\;10^{-6}$ M with linear sweep voltammetry. In case of using the differential pulse technique, we have obtained the linear response up to $7.0 {\times}10^{-7}$ M with relative standard deviation of ${\pm}5.1$%. The detection limit was $5.0{\times}10^{-7}$ M for 20 minutes of the deposition. We have investigated the interference effect of various metal ions, which are expected to form the complex with ligand. Silver (I) ion of these has interfered with the analysis of Hg (II) ions. However, pretreatment of the silver (I) ion with potassium chloride led to no interference on the analysis of mercury ions in aqueous solution.

  • PDF

Application of Environmental Planning Considering the Trend of PM10 in Ambient Air (미세먼지(PM10) 추세를 고려한 환경계획 적용 방향 제안)

  • Yoon, Eun Joo
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.210-218
    • /
    • 2020
  • Even though PM10 in ambient air has been steadily reduced, the perception of it has been deteriorated. Forthatreason, first, it can still be mentioned the annual average concentration of PM10 exceeding WHO standards, second, an increase in the number of high concentration days of PM10, and third, lack of consideration for differences in causes and phenomena of PM10 by regions. Therefore, this study was aimed to suggest management types for PM10 in ambient air by clustering 69 cities based on the trends and current levels of PM10. In addition, we proposed complementary measures such as the green infrastructure, ventilation corridors and adaptation measures (limit of exposure) for type III (distribution in the central inner region) and IV (metropolitan city, south-east coast region) where improvement of PM10 was insufficient. Although this study did not consider the cause of PM10 together, there is a significance that the scientific basis for responding to the near future is conducted based on past trends of PM10.

Evaluation of Soil Contamination by Copper Depleted from ACQ-Treated Wood (ACQ 방부처리목재로부터 용탈된 구리에 의한 토양오염 평가)

  • Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.504-510
    • /
    • 2015
  • This research was performed to evaluate soil contamination caused by copper depleted from ACQ-treated wood. Three years after the exposure of ACQ-treated wood in the field test sites, soil samples around the treated wood were collected and analyzed for the copper amount and distribution through soil. Soils around the deck posts installed in five different neighborhood parks located in Chonnam and Gyeongnam were investigated for copper contents. The results of the field test showed that the amount of copper leached from the end surface of treated wood buried under soil was more than 1.5 times the copper amount leached from the lateral surfaces, and the mobility of copper was very restricted in soil. The copper contents of soil within 10 cm from the treated deck posts installed in the parks showed to be less than 500 mg/kg, which are the limit values of the 2nd region set up by enforcement regulation of soil environment conservation act. The distribution ranges of copper in soil from the treated wood set up in the field test sites seemed to be much wider than those from deck posts, which may explained by the fact that the retentions of the treated samples used in the field test sites were much higher than those of the deck posts.

Bioanalytical method validation for determination of arsenic speciation in dog plasma using HPLC-ICP/MS (Dog 혈장 중 HPLC-ICP/MS를 이용한 비소 화학종 분석법 검증)

  • Kim, Jong-Hwan;Kwon, Young Sang;Shin, Min-Chul;Kim, Su Jong;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.234-241
    • /
    • 2016
  • The approach presented in this article refers to the bioanalytical method validation for the detection and quantitative determination of arsenic species including arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in dog plasma by high-performance liquid chromatography inductively coupled plasma mass spectrometry (HPLC-ICP/MS). The arsenic species were separated using an agilent As speciation column by a mobile phase of 2 mM sodium phosphate monobasic, 0.2 mM ethylenediaminetetraacetic acid disodium salt dehydrate, 10 mM sodium acetate, 3 mM sodium nitrate and 1 % ethyl alcohol at pH 11 (adjusted with 1M NaOH). The method validation experiment was obtained selectivity, linearity, accuracy, precision, matrix effect, recovery, system suitability, dilution integrity and various stabilities. All calibration curves showed good linearity (R2>0.999) within test ranges. The lower limit of quantitation (LLOQ) was 5 ng/mL for As(III), As(V) and DMA, and 20 ng/mL for MMA. The system suitability and dilution values were within 6.5 % and 7.7 %. Subsequently, the developed and validated HPLC-ICP/MS method was also successfully applied to determine the arsenic speciation in dog plasma samples, and the recoveries for the spiked samples were in the range of 91.5–102.2 %. Therefore, this method could be applied to the evaluation of arsenic exposure, health effect assessment and other bio-monitoring studies in biological samples.

Monitoring and Risk Assessment of Pesticide Residues in Commercial Environment-Friendly Agricultural Products Distributed Using LC-MS/MS in Seoul Metropolitan Area (LC-MS/MS를 이용한 수도권에 유통되는 친환경 농산물의 잔류농약 모니터링 및 안전성 평가)

  • Kim, Jong-Yul;Jung, Youmin;Oh, Hanseul;Kang, Sung-Tae
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.306-320
    • /
    • 2015
  • This survey was carried out in 2014 to estimate the pesticide residue levels in commercial environment-friendly agricultural products in Seoul metropolitan area. Pesticide residues in 27 commodities were examined and analyzed using LC-MS/MS, which can simultaneously detect up to 85 pesticides. A total of 441 samples were collected and analyzed. Among the detected samples, the residue levels in 1.2% of organic agricultural products and 2.2% of pesticide-free agricultural products exceeded the maximum residue limits (MRLs); hence, 1.8% of the total samples exceeded the MRLs. The safety of the detected pesticides was assessed by monitoring the acceptable daily intake level (ADI) and acceptable dietary exposure (ADE) to the pesticides via consumption of the commodities. ADI and ADE are found to be 0.07728-9.46530% and 0.00141-0.17210%, respectively, which means that the residual pesticides in the environmental-friendly agricultural products in Korea are below the safe limit and therefore, pose no potential public health risks.

Migration of Di-(2-ethylhexyl) Adipate into the Fresh Meat Wrapped with Plasticized PVC Film Depending on Fat Content, Thickness, Storage Temperature and Period (연질 PVC 필름에 포장된 생육류의 지방함량, 두께, 저장온도와 기간에 따른 Di-(2-ethylhexyl) Adipate의 이행량)

  • 홍승인;이근택
    • Food Science of Animal Resources
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2003
  • The effect of fat content, thickness, and storage temperature and period of fresh meat samples on the migration of di-(2-ethylhexyl) adipate(DEHA) from plasticized PVC film was investigated. Pork samples were prepared to have different fat contents by mixing with pork loin and pork backfat and stored at 5$^{\circ}C$ for 2 d. The migration values of DEHA into the pork samples were increased with a high fat content. There was a gradual increase in the DEHA concentration as a function of prolonged exposure period and elevated storage temperature when the pork samples were stored at -2, 5 and l0$^{\circ}C$ for up to 7 d, respectively. The migration of DEHA into fresh pork and beef was limited only to a small depth under the meat surface($\leq$2 cm). The migration value was higher when the pork belly was wrapped double with plasticized PVC film compared to once after storage at 5$^{\circ}C$ for 3 d. However, when the samples was minced and repacked with new film after 2 d, and kept for a further 1 d, these showed lower migration value compared to the above two intact samples. Migration values exceeded in most cases the upper limit for DEHA migration proposed by the EU(18 mg/kg or 3 mg/d㎡), even though no limitation is currently set in Korea.

Voltammetric Determination of Cu(II) Ion at a Chemically Modified Carbon-Paste Electrode Containing 1-(2-pyridylazo)-2-naphthol (1-(2-Pyridylazo)-2-naphthol 수식전극을 사용한 Cu(II) 이온의 전압전류법적 정량)

  • Jun-Ung Bae;Hee Sook Jun;Hye-Young Jang
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.723-729
    • /
    • 1993
  • Cu(II) ion-responsive chemically modifed electrodes (CMEs) were constructed by incorporating 1-(2-pyridylazo)-2-naphthol (PAN) into a conventional carbon-paste mixture of graphite powder and Nujol oil. Cu(II) ion was chemically deposited on the surface of the PAN-chemically modified electrode in the absence of an applied potential by immersion of the electrode in a buffer solution (pH 3.2) containing Cu(II) ion, and then reduced at a constant potential in 0.1 M KNO$_3$. And a well-defined voltammetric peak could be obtained by scanning the potential to the positive direction. The electrode surface could be regenerated with exposure to acid solution and reused for the determination of Cu(II) ion. In 5 deposition / measurement / regeneration cycles, the response could be reproduced with 6.1${\%}$ relative standard deviation. In case of using the differential pulse voltammetry, the calibration curve for Cu(II) was linear over the range of 2.0 ${times}$ 10$^{-7}$ ∼ 1.0 ${times}$ 10$^{-6}$ M. And the detection limit was 6.0 ${times}$ 10$^{-8}$ M. Studies of the effect of diverse ions showed that Co, Ni, Zn, Pb, Mg and Ag ions added 10 times more than Cu(II) ion did not influence on the determination of Cu(II) ion, except EDTA and oxalate ions.

  • PDF