진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구 (A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level)

  • 박혜민;윤용수;김은혜;정회원;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구 (The Review of Exposure Index in Digital Radiography and Image Quality)

  • 양숙;한재복;최남길;이성길
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.29-36
    • /
    • 2013
  • CR과 DR 장비에서 팬텀을 이용하여 선량과 노출지수(exposure index, EI)의 변화를 관찰하고 처리된 영상에서 NSR(noise to signal ratio)과 CNR (contrast to noise ratio)을 측정하여 디지털 시스템에서 방사선량을 최적화하기 위한 인자들 간의 상관관계를 알아보고자 하였다. EI와 입사표면선량(entrance surface dose, ESD)는 CR과 DR 장비에서 모두 주어진 선량의 증가에 따라 비례하여 증가하였다. 적정범위 내 EI 산출시 CR의 경우 DR 보다 더 많은 선량이 요구되었으나 두 시스템에서 모두 EI 지표는 노출인자인 kVp, mAs의 증가에 대해 선형으로 비례하여 증가하였다. 특히, 검출기 효율이 우수한 DR 시스템에서는 선량 변화에 대해 더 안정된 감도를 나타내었고, 최소의 선량증가에도 영상의 유용한 대조도를 형성하여 화질의 향상에 쉽게 도달할 수 있었다. 이는 검출기 흡수선량과 밀접한 관련이 있는 EI 지표의 정확성을 예측 가능하게 하였다. EI의 물리적 특징과 영상평가를 위한 NSR 측정은 DR 시스템에서 CR 보다 더 낮은 NSR이 나타났으며 CR에서는 6 mAs이상의 관전류에서는 관전압의 값에 따른 영향이 상대적으로 적었다. 본 연구 결론은 디지털 시스템 검출기의 흡수선량 측정의 지표인 EI는 노출인자와 선형비례관계에 있었고 EI가 제조사에서 제공한 범위 내에 존재할 때 그 EI 지표가 우수할수록 최적의 영상화질을 얻을 수 있었다. 또한 디지털 방사선 영상 기술에서 EI의 물리적 특징의 활용은 실제 임상에서 영상의 화질향상에 도움을 주고 검출기의 품질관리를 통하여 환자의 불필요한 피폭선량을 줄이는 데 많은 기여를 할 수 있을 것이다.

인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구 (A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

흉부방사선검사의 목표노출지수 설정을 위한 연구 (A Study to Establish Target Exposure Index for Chest Radiography)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.167-173
    • /
    • 2024
  • This study purpose to establish an appropriate target exposure index(EIT) using dose area product(DAP) and exposure index(EI) based on chest radiography. First, the system response experiment was conducted with radiation quality of RQA5 to compare the dosimetry and dose area product of equipment. Next, EI and DAP were acquired and analyzed while varying the dose in the diagnostic at 70kVp using a human body model phantom. The signal to noise ratio(SNR) of the obtained results was analyzed in the diagnostic with in the diagnostic reference level(DRL) application range. The DRL at percentage 25% had a dose of 0.17 mGy and EI was 83, and at percentage 75% the dose was 0.68 mGy and EI was 344. As the dose increased, the SNR in the subdiaphragm increased. To set the EIT, calibration must first be performed using a dosimeter and set within the DRL range to reflect the needs of the medical institution.

노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가 (Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination)

  • 박혜민;윤용수;김정수;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (I) (Evaluation of Image Receptor Characteristics in Computed Radiography System Using Exposure Index in International Electrotechnical Commission (I))

  • 박혜민;윤용수;노영훈;김성준;나찬영;한태호;김정수;정회원;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.291-299
    • /
    • 2019
  • The International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate the EI, w e obtained the characteristics curve of each image receptor by increasing the incident air kerma at RQA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.

Sub ROI 변화가 노출지수에 미치는 영향 (Effects of The Sub ROI Changes on Exposure Index)

  • 주영철;홍동희
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1149-1155
    • /
    • 2023
  • 본 연구에서는 Sub ROI의 변화가 노출지수(exposure index; EI)에 미치는 영향을 알아보고, 임상에서 Sub ROI 변경 시 발생될 수 있는 EI값의 변화에 대한 지표를 제시하고자 한다. 본 연구는 복부 방사선검사와 유사한 설정을 위해, 아크릴 20 cm의 피사체를 대상으로 진행하였고, 아크릴 한 장의 제원은 20×20×5 cm이다. 조사조건은 80 kVp , 320 mA, 25 ms, SID 110 cm로 동일하게 적용하였으며, Sub ROI는 장비사에서 제공하는 5가지 type을 이용하여 각 type별 30개의 영상을 획득하였고, 장비에서 제공하는 EI값과 환자입사선량(entrance skin exposure; ESE)를 비교분석 하였다. Sub ROI 변화에 따른 EI의 평균값은 LS의 경우 101.18±0.27 이었으며, AEC는 106.57±0.31, VR은 107.74±0.39, HR은 107.90±0.38, SS는 109.72±0.32로 나타났다(p<0.01). Sub ROI 타입 별(LS, AEC, VR, HR, SS) ESE 평균값은 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, 477.14±1.46 μGy로 측정되었고, 통계적으로 유의한 차이가 있었다(p<0.01). 본 연구결과 Sub ROI 타입에 따른 EI는 최소값을 나타낸 LS(109.72)를 기준으로, AEC는 5.3%, VR은 6.4%, HR은 6.6%, SS는 8.4% 증가하였으며, 평균적으로 5.3% 증가하였다. ESE의 평균값은 HR(475.61 μGy)타입이 최소값을 나타냈으며, 이를 기준으로 AEC는 0.27%, VR은 0.11%, LS는 0.17%, SS는 0.32% 증가하였고, 전체 적으로 약 0.17% 높아졌다.

흉부 후·전방향 검사 시 보조관심영역의 변화가 노출지수와 입사표면선량에 미치는 영향 (An Effect to the Exposure Index and Entrance Surface Dose according to the Sub-ROI in Chest PA Radiography)

  • 장용희;안호찬;김한용;김동환;주영철
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.685-691
    • /
    • 2023
  • 본 연구는 흉부 후·전방향 검사 시 보조관심영역의 변화가 노출지수와 선량에 미치는 영향에 대한 연구를 통해, 임상에서 적절한 보조관심영역 적용에 대한 인식을 제고하고자 한다. 본 연구는 흉부 모형 팬텀을 대상으로 하였고, 조사조건은 120 kVp, 200 mA, 2 mAs로 설정하였으며, 조사야 크기는 영상수용체 전체를 포함하는 크기(17 X 17")를 적용했다. Sub-ROI는 장비 제조사에서 제공하는 다섯 가지 방식(AEC, VR, HR, LS, SS)를 이용하였다. Sub-ROI 변화에 따른 EI의 평균값은 AEC의 경우 135.58 ± 0.89, VR은 100.80 ± 0.80, HR은 143.43 ± 0.76, LS는 103.22 ± 0.68, SS는 102.79 ± 0.84로 나타났으며, ESD의 평균값은 AEC의 경우 30.28 ± 0.50 µGy, VR은 30.16 ± 0.44 µGy, HR은 30.30 ± 0.46 µGy, LS는 30.23 ± 0.46 µGy, SS는 30.28 ± 0.51 µGy으로 측정되었다. 본 연구 결과, EI는 제조사에서 권고하는 AEC 모드를 기준으로 VR (25.7%)과 LS (23.9%), SS (24.2%)모드는 감소하였으며, HR 모드는 5.7% 증가하였다. 하지만, ESD는 Sub-ROI 변화에 영향을 받지 않았다. 그러므로 임상에서 Chest PA 검사 시 Sub-ROI에 따라서 EI가 변경될 수 있으니, 임상에서는 이점을 유의하여 검사조건 설정 시 Sub-ROI를 적절하게 사용해야 한다고 사료된다.

손 방사선검사에서 조사야 크기와 보조관심영역 변화가 노출지수 값에 미치는 영향 (Effects of Changes in Collimation Size and the sub ROI on Exposure Index of Hand Radiography)

  • 주영철;홍동희
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.851-857
    • /
    • 2023
  • 본 연구는 손 방사선검사에서 조사야 크기와 sub ROI의 변화가 EI값에 미치는 영향을 알아보고, 한국인의 평균 손 크기에 적합한 조사야 크기 및 EI값 제시하고, sub ROI 변화가 EI 값에 미치는 영향을 제시하는데 목적이 있다. hand wrist phantom을 대상으로 했으며, 조사조건은 55 kVp, 125 mA, 6.25 mAs로 설정하였고, 초점-영상수용체 간 거리는 110 cm로 적용하였다. 제조사에서 권고하는 sub ROI('ss' 타입)을 기준으로 조사야 크기 4종류(18.7"×18.7", 8"×10", 8"×7.4", 6"×7.4")와 교과서에서 권고하는 조사야 크기 8"×10"에서 sub ROI 5가지를 변화 시키며, 각각 30개의 영상을 획득하였고, 이때 장비에서 나타나는 EI를 비교분석하였다. 조사야 크기 변화에 따른 EI값은 18.7"×18.7"의 경우 1663.7±4.52, 8"×10"은 1489.1±4.49, 8"×7.4"은 1716.9±3.00, 6"×7.4"은 1681.7±3.66로 나타났으며, 각 값의 평균값은 통계적으로 유의했다. sub ROI 변화에 따른 EI값의 평균은 SS의 경우 1489.1±4.49이었으며, LS는 1694.8±5.19, AEC는 2052.9±5.96, VR은 1548.3±3.20, HR은 1663.2±4.33로 나타났다. 한국인의 손 크기를 고려한 적절한 조사야 크기는 8"×7.4"로 나타났다. 또한 손 방사선검사 시 일반적으로 알려진 조사야 크기(8"×10")를 기준으로 조사야 크기가 증가하면 EI값은 최대 15%에서 최소 11%까지 변화되었으며, sub ROI 'SS'를 기준으로 sub ROI 형태 변화에 따른 EI값은 최대 37%에서 최소 3%까지 증가하였다.

조선소 도장작업 노동자 유기용제 노출과 일간 변이 (Characteristics of Workers'Exposure Concentration and Daily Variations to Organic Solvents in Shipbuilding Painting Processes)

  • 안진수;박두용;강태선
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.488-499
    • /
    • 2019
  • Objectives: This study was conducted to identify the characterization of organics solvent exposure among painting workers in the shipbuilding painting process, especially for their daily variations(within worker variance). Methods: Charcoal passive dosimeters were worn throughout each work shift for 20 days for five painting workers from October 19 to November 26, 2015. A total of 100 samples were collected, analyzed and compared with statutory workplace environmental measurements. Results: The geometric mean(GM) and geometric standard deviation(GSD) of mixed organic solvent(six substances) exposure index(EI) for the 100 samples were 0.42 and 4.42 respectively. The median and range of GSD for within worker EI representing five workers' daily EI variation is 3.72 and 2.63 ~ 5.20, respectively, which is classified as a very large variation(GSD>3). We were able to divide the painting process into two similar exposure groups(SEGs), Touch-up and Spray. Spray painting workers were much more exposed to organic solvent than Touch-up painting workers(GM=0.71 vs. 0.19), but less variably (GSD=3.64 vs. 4.10). xylene is the substance to which the workers were most exposed(GM=16.19 ppm, GSD=4.36), and the exposure characteristics of six substances including xylene is similar to those of EI. Conclusions: The daily variation of organic solvent exposure in the shipbuilding painting process is so high that statutory Assessment of Reliability of Work Environment Monitoring needs to be conducted with statistically sufficient number of samples and evidence.