• Title/Summary/Keyword: exposed times

Search Result 1,095, Processing Time 0.029 seconds

Evaluation of Flexural Performance of RC Beams Using Polymer Cementitous Mortar (폴리머시멘트 모르터를 이용한 RC 보의 휨 성능평가)

  • 양동석;고원준;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.479-484
    • /
    • 2000
  • An experimental study to investigate the structural performance of reinforced concrete beams repaired by Polymer Cementitous Mortar in the tension zone is described. Preliminary trials with beams in which beams tensile reinforcing steel was exposed over 100%, 80% and 60% of their length have led to tests on $5\times25$cm beams over a 200cm span to examine the experimental parameter. Attention is concentrated upon overall bending capacity, deflection and crack development of repaired beams.

  • PDF

Analysis of RC Columns under High Temperature (고온에 노출된 철근콘크리트 기둥의 거동 해석)

  • 이지웅;홍성걸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.625-628
    • /
    • 2003
  • This paper presents the behaviors of reinforced concrete columns under high temperature. When columns are exposed high temperature, temperature distribution of a section becomes nonlinear and it is calculated by using finite difference method(F.D.M). The interaction curves show the strength of columns at various exposure times. The strength of columns decreases according to the increase of the exposure time and the decrease of concrete cover.

  • PDF

Distribution of Microorganisms and Foodborne Pathogens in Yukae (육회 중에 분포하는 미생물과 주요 식중독 세균의 조사)

  • Lee, Si-Hyung;Kim, Jin-Man;Kim, Myung-Hee
    • the MEAT Journal
    • /
    • s.35 winter
    • /
    • pp.34-45
    • /
    • 2008
  • People can be exposed to various microorganisms when they eat yukae (seasoned raw meat) because yukae is eaten raw. The purpose of this study was to find out microbial distribution in yukae. In this experiment, 5 restaurants serving yukae were chosen in Daegu area. Mesophilic microorganisms and coliforms were measured by Korean Food Standards Codex. Analyses of Salmonella spp., Listeria monocytogenes, Staphylococcus aureus and Escherichia coli O157:H7 were conducted. As results, mesophilic microorganisms ranged 6.6$\times$103-2.7$\times$105 CFU/g and coliforms ranged 8.9$\times$101-2.1$\times$105 CFU/g. Salmonella spp., Listeria monocytogenes and Escherichia coli O157:H7 were not detected in all 5 samples. However, Staphylococcus aureus was detected in 1 sample out of 5 samples. Hygiene practice during production, processing and cooking process is required.

  • PDF

Distribution of Microorganisms and Foodborne Pathogens in Yukae (육회 중에 분포하는 미생물과 주요 식중독 세균의 조사)

  • Lee, Si-Hyung;Kim, Jin-Man;Kim, Myung-Hee
    • Food Science of Animal Resources
    • /
    • v.27 no.2
    • /
    • pp.197-202
    • /
    • 2007
  • People can be exposed to various microorganisms when they eat yukae(seasoned raw meat) because yukae is eaten raw. The purpose of this study was to find out microbial distribution in yukae. In this experiment, 5 restaurants serving yukae were chosen in Daegu area. Mesophilic microorganisms and coliforms were measured by Korean Food Standards Codex. Analyses of Salmonella spp., Listeria monocytogenes, Staphylococcus aureus and Escherichia coli O157:H7 were conducted. As results, mesophilic microorganisms ranged $6.6{\times}10^3-2.7{\times}10^5\;CFU/g$ and coliforms ranged $8.9{\times}10^1-2.1{\times}10^5CFU/g$. Salmonella spp., Listeria monocytogenes and Escherichia coli O157:H7 were not detected in all 5 samples. However, Staphylococcus aureus was detected in 1 sample out of 5 samples. Hygiene practice during production, processing and cooking process is required.

Application of Multiparametric Flow Cytometry (FCM) to Enumerate the Diagnosis of Pseudomonas aeruginosa and Escherichia coli

  • Hwang, Myoung-Goo;Oh, Jung-Woo;Katayama, Hiroyuki;Ohgaki, Shinichiro;Cho, Jin-Kyu
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 2012
  • In this study, multiparametric flow cytometry (FCM) was installed to enumerate the diagnosis of Pseudomonas aeruginosa ATCC 10145 and Escherichia coli K12 (IFO 3301). The nucleic acids (DNA/RNA) were double stained by a LIVE/DEAD bacLight viability kit, involving green SYTO 9 and red propidium iodide (PI), based on the permeability of two chemicals according to the integrity of plasma membrane. As the results showed, the gate for dead bacteria was defined as the range of $0.2{\times}10^0$ to $6.0{\times}10^1$ photo multiplier tube (PMT) 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $2.0{\times}10^2$ PMT 4 fluorescence (Y-axis), and the gate for live bacteria was defined as the range of $6.0{\times}10^0$ to $6.0{\times}10^2$ PMT 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $4.0{\times}10^2$ PMT 4 fluorescence (Y-axis). In the comparison of the number of the tested bacteria detected by FCM (viability assessment) and plate culture (cultivability assessment), the number of bacteria detected by FCM well represented the number of bacteria that was detected by the colony forming unit (CFU) counting method when bacteria were exposed to isopropyl alcohol and silver/copper cations. Consequently, it is concluded that the application of FCM to monitor the functional effect of disinfectants on the physiological status of target bacteria can offer more rapid and reliable data than the plate culture colony counting method.

Fabrication of pyroelectric infrared sensors using PLT thin plates (PLT 박편을 이용한 초전형 적외선 센서의 제작)

  • Kim, Young-Eil;Roh, Yong-Rae
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • High-sensitive pyroelectric infrared sensors have been fabricated with La-modified $PbTiO_{3}$(PLT) thin plates. The PLT thin plates have the composition of $(Pb_{0.9}La_{0.1}Ti_{0.75}O_{3})_{0.75}(PbO)_{0.25}$. Thickness of the thin plates is $100\;{\mu}m$. Top side electrodes exposed to IR are vacuum evaporated Ni-Cr, and bottom side electrodes are Ag. Each one takes the area of $1{\times}2\;mm^{2}$. The thin plates have a large resistivity of $6.41{\times}10^{10}{\Omega}{\cdot}cm$ and a relative dielectric constant of 341. They have a high figure of merit of $4.0{\times}10^{-11}\;Ccm/J$ due to its high pyroelectric coefficient of $4.45{\times}10^{-8}\;C/cm^{2}K$. The sensors show such a large voltage responsivity as 2501 V/W. That they can find practical applications like the pyroelectric infrared detectors.

  • PDF

Exposure to Benzene Associated with Gasoline and Environmental Tobacco Smoke (휘발유 및 환경 담배 연기 관련 벤젠 노출)

  • 조완근;문경조
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.319-323
    • /
    • 1999
  • This study was designed to evaluate the exposure to benzene by residents in neighborhoods near a major roadways, by persons waiting buses, and by drivers and service station attendants while refueling. It was confirmed that the outdoor air benzene concentrations near the major roadways were higher than those further away from the sources. However, neither the indoor air nor breath concentrations were different for two specified residential areas. Smoking was confirmed as an important factor for the indoor air benzene levels. Persons waiting buses, drivers and service station attendants were exposed to elevated benzene levels compared to even the residents in neighborhoods near a major roadways. The mean benzene concentration at bus stop was 2.7 to 6.9 times higher than the mean ambient air concentration. The mean benzene concentrations in the breathing zone of drivers and service station attendants were 95 to 160 and 120 to 202 times higher than the mean ambient air concentrations, respectively.

  • PDF

Endodermal Cyst of the Posterior Fossa

  • Lee, Chul-Woo;Yoon, Seok-Mann;Kim, Yoon-Jung;Yun, Il-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.4
    • /
    • pp.310-312
    • /
    • 2005
  • We report a case of endodermal cyst of the posterior fossa. A 44-year-old man presented with headache for three months. Computed tomography and magnetic resonance imaging revealed a $6{\times}2.5{\times}2cm$ sized extra-axial non-enhancing cystic lesion on the ventral aspect to brain stem. To avoid retraction injury to brain stem, far lateral transcondylar approach was selected. Right suboccipital craniotomy and partial removal of occipital condyle with resection of C-1 and C-2 hemilaminae exposed the extra-axial cyst well. The cyst has a whitish thick membrane. It was not adherent to brain stem and lower cranial nerves. Total removal of the cyst was done without difficulty. Histological analysis disclosed a layer of pseudostratified columnar epithelium with basement membrane. The result of immunohistochemical study was consistent with endodermal cyst.

Aging Characteristics of Glass Fabric/Phenolic Composites in Train Carbody (철도차량용 유리섬유직물/페놀릭 복합재의 가속노화 특성)

  • Yoon Sung-Ho;Nam Jung-Pyo;Hwang Young-Eun;Shin Kwang-Bok
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.352-357
    • /
    • 2004
  • In this study. the effects of combined environmental factors on mechanical and thermal analysis properties of graphite/epoxy composites were evaluated through a 2.5KW accelerated environmental aging tester. Environmental factors such as temperature. moisture, and ultraviolet were considered. A xenon-arc lamp was utilized for ultraviolet light. and exposure times of up to 3000 hours were applied. Several types of specimens - tensile, bending, and shear specimens those are warp direction and fill direction were used to investigate the effects of environmental factors on mechanical properties of the composites. The glass fabric $\sharp$650/AP300 was used for the fabrication of specimens. Mechanical degradations for tensile, bending and shear properties were evaluated through a UTM. Also. storage shear modulus. loss shear modulus, and tan $\delta$ were measured as a function of exposure times through a dynamic mechanical analyzer. Finally exposed surfaces of the composites were examined using II scanning electron microscope.

  • PDF

Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques

  • Mamoun, John
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.2
    • /
    • pp.52-58
    • /
    • 2018
  • Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of $6{\times}$ to $8{\times}$ or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions.