• Title/Summary/Keyword: explosive gases classification

Search Result 8, Processing Time 0.03 seconds

Micro Sensor Away and its Application to Recognizing Explosive Gases (마이크로 센서 어레이 제작 및 폭발성 가스 인식으로의 응용)

  • 이대식;이덕동
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.1
    • /
    • pp.11-19
    • /
    • 2003
  • A micro sensor array with 4 discrete sensors integrated on a microhotplate was developed for identifying the kinds and quantities of explosive gases. The sensor array consisited of four tin oxide-based thin films with the high and broad sensitivity to the tested explosive gases and uniform thermal distribution on the plate. The microhotplate, using silicon substrate with N/O/N membrane, dangling in air by Al bonding wires, and controlling the thickness by chemical mechanical process (CMP), has been designed and fabricated. By employing the sensitivity signal of the sensor array at 40$0^{\circ}C$, we could reliably classily the kinds and quantities of the explosive gases like butan, propane, LPG, and carbon monoxide within the range of threshold limit values (TLVs), employing principal component analysis (PCA).

An explosive gas recognition system using neural networks (신경회로망을 이용한 폭발성 가스 인식 시스템)

  • Ban, Sang-Woo;Cho, Jun-Ki;Lee, Min-Ho;Lee, Dae-Sik;Jung, Ho-Yong;Huh, Jeung-Soo;lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.461-468
    • /
    • 1999
  • In this paper, we have implemented a gas recognition system for classification and identification of explosive gases such as methane, propane, and butane using a sensor array and an artificial neural network. Such explosive gases which can be usually detected in the oil factory and LPG pipeline are very dangerous for a human being. We analyzed the characteristics of a multi-dimensional sensor signals obtained from the nine sensors using the principal component analysis(PCA) technique. Also, we implemented a gas pattern recognizer using a multi-layer neural network with error back propagation learning algorithm, which can classify and identify the sorts of gases and concentrations for each gas. The simulation and experimental results show that the proposed gas recognition system is effective to identify the explosive gases. And also, we used DSP board(TMS320C31) to implement the proposed gas recognition system using the neural network for real time processing.

  • PDF

A Study on Explosion Risk Management for Hot Oil Heater (열매체 가열기 설비에서의 폭발위험관리에 관한 연구)

  • Jang, Chul;Kwon, Jin-Wook;Hwang, Myoung-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2017
  • In the industrial field, various type of fuel have been used for product processing facilities. Recent for 10 years, the usage of natural gas (NG) was gradually increased. Because it has many merits; clean fuel, no transportation, storage facility and so on. There are common safety concept that strict explosion protection approaches are needed for facilities where explosive materials such as flammable liquid, vapor and gases exist. But some has an optimistic point of view that the lighter than air gases such as NG disperse rapidly, hence do not form explosion environment upon release into the atmosphere, many parts has a conventional safety point of view that those gases are also inflammable gases, hence can form explosion environment although the extent is limited and present. In this paper, the heating equipments (Hot Oil Heater) was reviewed and some risk management measures were proposed. These measures include hazardous area classification and explosion-proof provisions of electric apparatus, an early gas leak detection and isolation, ventilation system reliability, emergency response plan and training and so on. This study calculates Hazardous Area Classification using the hypothetical volume in the KS C IEC code.

A Comparison on Detected Concentrations of LPG Leakage Distribution through Actual Gas Release, CFD (FLACS) and Calculation of Hazardous Areas (가스 누출 실험, CFD 및 거리산출 비교를 통한 LP가스 누출 검지농도 분포에 대한 고찰)

  • Kim, Jeong Hwan;Lee, Min-Kyeong
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.102-109
    • /
    • 2021
  • Recently, an interest in risk calculation methods has been increasing in Korea due to the establishment of classification code for explosive hazardous area on gas facility (KGS CODE GC101), which is based on the international standard of classification of areas - explosive gas atmospheres (IEC 60079-10-1). However, experiments to check for leaks of combustible or toxic gases are very difficult. These experiments can lead to fire, explosion, and toxic poisoning. Therefore, even if someone tries to provide a laboratory for this experiment, it is difficult to install a gas leakage equipment. In this study we find out differences among actual experiments, CFD by using FLACS and calculation based on classification code for explosive hazardous area on gas facility (KGS CODE GC101) by comparing to each other. We develpoed KGS HAC (hazardous area classification) program which based on KGS GC101 for convenience and popularization. As a result, actual gas leak, CFD and KGS HAC are showing slightly different results. The results of dispersion of 1.8 to 2.7 m were shown in the actual experiment, and the CFD and KGS HAC showed a linear increase of about 0.4 to 1 m depending on the increase in a flow rate. In the actual experiment, the application of 3/8" tubes and orifice to take into account the momentum drop resulted in an increase in the hazardous distance of about 1.95 m. Comparing three methods was able to identify similarities between real and CFD, and also similarities and limitations of CFD and KGS HAC. We hope these results will provide a good basis for future experiments and risk calculations.

Electrical Machines and Drives for Potentially Explosive Atmospheres

  • Grantham, Colin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • This paper gives an overview of the requirements for electrical equipment in potentially explosive atmospheres and describes how these are applied to electrical machines and drives in hazardous areas. The method by which equipment can be shown to be safe in a whole range of gases, by testing in a single test gas, is covered. It is shown how the more recently introduced methods of protection for hazardous areas, increased safety and nonsparking, are ideally suited to AC machines and drives. A novel method of measuring the fullload temperature rise of electrical machines for hazardous, and other areas, without the need to connect a mechanical load to the machine's drive shaft is explained.

Technical/Systemic Approach to Safety Assesment of Thermoprocessing Equipment Consuming LNG for Classification of Hazardous Area (LNG를 사용하는 설비에서의 폭발위험장소 적용 및 구분에 대한 제도/기술적 접근방안)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.33-40
    • /
    • 2011
  • In the hazardous areas where explosive liquids, vapors and gases exist, electrical apparatus/equipment should have explosion-proof construction. The consuming of liquefied natural gas(LNG) has markedly increased in the industrial field, especially in aspect of some thermoprocessing equipment, boiler, dryer, furnace, annealer, kiln, regenerative thermal oxidizer(RTO) and so on. Because it has many merits, clean fuel, safety, no transportation/storage facility and so on. It is strongly recommend that the classification of hazards has to be decided to prevent and protect explosion which may occur in thermoprocessing equipment. In this paper, the operated thermoprocessing equipments in industrial area investigated and explosion risk assessment about LNG leakage from its facilities was performed through numerical calculation and computer simulation. Finally, we suggest the systemic/technical approach for safety assessments of thermoprocessing equipments consumed LNG fuel which are specially subjected to classification of hazardous area.

Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus (비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法))

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF

Specific Process Conditions for Non-Hazardous Classification of Hydrogen Handling Facilities

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.416-420
    • /
    • 2021
  • Hazardous area classification design is required to reduce the explosion risk in process plants. Among the international design guidelines, only IEC 60079-10-1 proposes a new type of zone, namely zone 2 NE, to prevent explosion hazards. We studied how to meet the zone 2 NE grade for a facility handling hydrogen gas, which is considered as most dangerous among explosive gases. Zone 2 NE can be achieved considering the grade of release, as well as the availability and effectiveness of ventilation, which are factors indicative of the facility condition and its surroundings. In the present study, we demonstrate that zone 2 NE can be achieved when the degree of ventilation is high by accessing temperature, pressure, and size of leak hole. The release characteristic can be derived by substituting the process condition of the hydrogen gas facility. The equations are summarized considering relation of the operating temperature, operating pressure, and size of leak hole. Through this relationship, the non-hazardous condition can be realized from the perspective of inherent safety by the combination of each parameter before the initial design of the hydrogen gas facility.