• 제목/요약/키워드: explosion proof

검색결과 78건 처리시간 0.031초

접촉폭발에 의한 섬유보강 시멘트 복합체의 방폭성능 (Explosion Proof of Fiber Reinforced Cement Composite Panel subjected to Contact Explosion)

  • 김윤환;김규용;김홍섭;이보경;이상규;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.128-129
    • /
    • 2016
  • This paper evaluates experimentally the explosion proof of fiber reinforced cement composite(FRCC) panels with various fibers of 2 % volume fraction subjected to contact explosions using an emulsion explosive. As a results, the proportion of the total damage in FRCC panels is not biased scabbing on the rear side with contrast to plain panels, which means that the local damage of FRCC panels was significantly controlled. The experimental results presented useful information for prediction of limited thickness on the local damage subjected to contact explosions through comparison with existing damage evaluation prediction equations.

  • PDF

내압방폭을 위한 Safe Gap의 측정에 관한 연구 (A Study on the Safe Gap for Explosion-proof)

  • 오규형
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.1-6
    • /
    • 1997
  • 가연성 가스가 존재하는 위험 분위기에서 전기기기를 사용할 경우 전기 스파크에 의한 폭발위험성이 존재하기 때문에 점화원을 격리시키거나 고립시키는 것이 필요하지만 현실적으로 점화원의 고립이 불가능하므로 폭발을 방지하기 위한 일반적인 방법으로 내압 방폭형전기기기를 사용하고 있다. 따라서 내압방폭기기의 내부에 침투한 가연성 가스가 폭발하여도 화염이나 열이 틈새를 통과하여 외부의 가연성 분위기를 점화시킬 수 없는 최대 틈새크기를 찾아야 할 필요가 있다. 본 논문에서는 수소-공기 혼합기와 메탄-공기 혼합기에 대하여 실험적 최대틈새크기(MESG)를 찾아내어 기존의 결과와 비교하고, MESG에 영향을 미치는 요인들을 찾아내고자 하였다. 실험장치는 내용적 8${\iota}$의 구형용기를 사용하였으며 실험 변수들로는 전화위치, 혼합기의 농도, 초기압력 등이었다. 실험결과 각각의 변수들에 의해 영향을 받으며 특히 농도와 초기압력에 크게 영향을 받는 것을 알 수 있었으며, 당량 농도 가까이에서 최소값을 나타내었으며 초기압력의 상승과 함께 MESG는 감소하였다.

  • PDF

위상최적화 기법을 이용한 반도체 공정용 압력방폭형 외함 도어의 보강 패턴 최적화 (Topology Optimization of Reinforcement Pattern for Pressure-Explosion Proof Enclosure Door in Semiconductor Manufacturing Process )

  • 김영상;신동석;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제22권2호
    • /
    • pp.56-63
    • /
    • 2023
  • This paper presents a method using finite element analysis and topology optimization to address the issue of overdesign in pressure-explosion proof enclosure doors for semiconductor manufacturing processes. The design conducted in this paper focuses on the pattern design of the enclosure door and its fixation components. The process consists of a solid-filled model, a topology optimization model, and a post-processing model. By applying environmental conditions to each model and comparing the maximum displacement, maximum equivalent stress, and weight values, it was confirmed that a reduction of about 13% in weight is achievable.

  • PDF

저압 도시가스 사용설비의 누출 조건에 따른 폭발 위험 분위기 형성 범위 예측에 관한 연구 (A study on the Prediction of Explosion Risk for the Low Pressure Natural Gas Facilities with Different Explosion Conditions)

  • 한상일;이동욱;황규석
    • 한국가스학회지
    • /
    • 제20권3호
    • /
    • pp.59-65
    • /
    • 2016
  • 가스 사용 시설에서 폭발 위험성 평가 등급에 따라 적합한 방폭용 설비를 사용하는 것은 매우 중요하다. 가스 관련 법에서 가스 사용시설의 방폭 기준은 제시하고 있으나 폭발 위험장소 구분을 위한 기술 기준은 별도로 제시되어 있지 않다. 본 연구에서 한국산업표준 KS를 이용하여 저압 도시가스 배관시설에 대해 합리적인 폭발위험성 예측 방법을 제시하고자 한다. 누출공 크기, 누출압력에 따른 가상체적, 환기 유효성 등의 중요변수를 적용하여 폭발위험성이 예측되었다. 자연 환기 조건을 만족하는 실험 설비가 제작되어 도시 가스 누출 실험 결과와 KS 표준에 의해 예측된 폭발 위험성 예측 결과가 비교되었다.

AC/DC 12~254 V로 동작하는 방폭 LED Signal Lamp용 방폭 회로의 특성 분석 (Characteristic Analysis of a Ex Circuit of Ex LED Signal Lamp Operating with AC/DC 12~254 V)

  • 정민주;허인성;강인철;유영문
    • 한국전기전자재료학회논문지
    • /
    • 제27권11호
    • /
    • pp.690-695
    • /
    • 2014
  • In this paper, we develop a explosion-proof LED lighting (Ex circuit) circuit of Explosion-proof LED Signal Lamp (Ex LSL) to utilize the core module of the explosion-proof Local Control System (Ex LCS) for offshore plant applications. And then analyzed its electrical, optical and thermal characteristics. Ex circuit was applied input voltage from AC/DC(12~254) V. In this experiments, stable light-on characteristics were confirmed by eyes for the every input voltages with min. 78,462 and max. $517,975cd/m^2$ of luminance. also Output current and output luminance was made proportional. Because the measured maximum surface temperature of Ex circuit was $54.23^{\circ}C$ at AC 48 V, Ex circuit was rated with T6 of temperature class. Finally, Ex circuit was shown stable light on characteristics under the $-50^{\circ}C$ and $60^{\circ}C$ during 12 hours of test period.

방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구 (A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof)

  • 박규태;유근준;조영도;권정락;안상국;김희식
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.1-12
    • /
    • 2014
  • 본 논문에서는 적외선센서를 이용하여 방폭형 휴대용 가연성가스 누출검지기를 개발하고 아울러 가스의 농도를 측정하는 정확도를 향상시키는 알고리즘을 제안하였다. 국내최초로 내압 및 본질안전방폭규격(Ex d ib) 적용하여 적외선 가스누출검지기는 개발하였으며, 선형회귀 방정식과 2차 라그랑지(Lagrange) 보간 다항식(interpolation polynomial)을 사용하여 측정정확도를 개선하였다. 아울러 본 연구에서는 현장검사원들의 요구사항을 조사하여 현장에 부합하도록 성능을 향상시키고, 편의기능을 추가하였다. 본 연구에서 개발한 가스누출검지기와 타사의 검지기를 비교하기 위하여 한국가스안전공사에서 제조한 표준가스 8종을 가지고 측정시험을 실시하였다. 본 연구에서 개발한 가스누출검지기의 검지 정확도가 우수함을 실험결과를 통하여 증명하였다.

Dynamic performance of girder bridges with explosion-proof and aseismic system

  • Wang, Jingyu;Yuan, Wancheng;Wu, Xun;Wei, Kai
    • Structural Engineering and Mechanics
    • /
    • 제61권3호
    • /
    • pp.419-426
    • /
    • 2017
  • Recently, the transportation of dangerous explosive goods is increasing, which makes vehicle blasting accidents a potential threat for the safety of bridge structures. In addition, blasting accidents happen more easily when earthquake occurs. Excessive dynamic response of bridges under extreme loads may cause local member damage, serviceability issues, or even failure of the whole structure. In this paper, a new explosion-proof and aseismic system is proposed including cable support damping bearing and steel-fiber reinforced concrete based on the existing researches. Then, considering one 40m-span simply supported concrete T-bridge as the prototype, through scale model test and numerical simulation, the dynamic response of the bridge under three conditions including only earthquake, only blast load and the combination of the two extreme loads is obtained and the applicability of this explosion-proof and aseismic system is explored. Results of the study show that this explosion-proof and aseismic system has good adaptability to seism and blast load at different level. The reducing vibration isolation efficiency of cable support damping bearing is pretty high. Increasing cables does not affect the good shock-absorption performance of the original bearing. The new system is good at shock absorption and displacement limitation. It works well in reducing the vertical dynamic response of beam body, and could limit the relative displacement between main girder and capping beam in different orientation so as to solve the problem of beam falling. The study also shows that the enhancement of steel fibers in concrete could significantly improve the blast resistance of main beam. Results of this paper can be used in the process of antiknock design, and provide strong theoretical basis for comprehensive protection and support of girder bridges.

암모니아 냉동시설의 폭발사례 분석을 통한 재발방지대책 (Measures to Prevent Recurrence through the Analysis of an Explosion Case at Ammonia Refrigeration Facilities)

  • 류영조;이민경;이수경
    • 한국가스학회지
    • /
    • 제20권3호
    • /
    • pp.38-45
    • /
    • 2016
  • 이 논문에서 암모니아 가스의 실내 누출 및 확산 현상을 FLACS 소프트웨어를 이용하여 시뮬레이션한 결과, 암모니아 가스가 실내에서 폭발 위험분위기를 쉽게 형성함을 확인하였다. 따라서 암모니아 가스를 냉매가스로 사용하는 고압가스 냉동제조시설의 냉동실은 환기장치를 갖추거나 가스누출검지경보장치를 설치하여야 한다. 그러나 냉동시설의 특성상 이들 설비를 설치할 수 없기 때문에 재발방지대책으로 암모니아 가스설비의 전기설비는 방폭구조로 설치하고 고압가스 냉동제조시설에서 가스누출 등의 이상사태가 발생하는 경우에 사업장 안의 모든 종사자가 신속히 대피할 수 있도록 통신시설을 설치할 필요가 있다.