• Title/Summary/Keyword: experimental fire tests

Search Result 156, Processing Time 0.02 seconds

STRUCTURAL TEST AND ANALYSIS OF RC SLAB AFTER FIRE LOADING

  • Chung, Chul-Hun;Im, Cho Rong;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.223-236
    • /
    • 2013
  • In the present study the behavior of fire and the residual strength of fire-ignited RC slabs are investigated by experimental tests and numerical simulations. The fire tests of RC slabs were carried out in a furnace using the ISO 834 standard fire. The load capacity of the cooled RC slabs that were not loaded during the fire tests was evaluated by additional 3 point bending tests. The influence of the proportion of PP (polypropylene) fibers in the RC slabs on the structural behavior of the RC slabs after the fire loading was investigated. The results of the fire tests showed that the maximum temperature of concrete with PP fiber was lower than that of concrete without PP fiber. As the concrete was heated, the ultimate compressive strength decreased and the ultimate strain increased. The load-deflection relations of RC slabs after fire loading were compared by using existing stress-strain-temperature models. The comparison between the numerical analysis and the experimental tests showed that some numerical analyses were reliable and therefore, can be applied to evaluate the ultimate load of RC slabs after fire loading. The ultimate load capacity after cooling down the RC slabs without PP fiber showed a considerable reduction from that of the RC slabs with PP fiber.

A State-of-art of Experimental Research and Calculated Models of Dowel-type Timber Connections in Fire

  • Luo, Jing;He, Minjuan;Li, Zheng
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.285-297
    • /
    • 2021
  • Fire safety is one of the most significant issues for the design of mid-rise and high-rise timber structures. A large number of experimental tests were conducted during the last three decades to investigate the fire performance of the dowel-type timber connections. Many influenced parameters (e.g. the thickness of the side timber, the load ratio, the fasteners type etc.) were considered in those experiments. Relevant calculated models were proposed by previous researchers to estimate the fire resistance of the connections. In this study, a series of experimental programs of dowel-type connections in fire are collected. Then, empirical formulas proposed by EN 1995-1-2, Fire safety in timber buildings, and previous researchers are presented and analyzed. The accuracy of those formulas is checked by comparisons between the experimental data and estimated results. The collected experimental research and empirical formulas can be used as the reference for the fire design of dowel-type timber connections in the future.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • v.12 no.4
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

Experimental investigation of the behaviour of a steel sub-frame under a natural fire

  • Santiago, Aldina;Simoes da Silva, Luis;Vaz, Gilberto;Vila Real, Paulo;Lopes, Antonio Gameiro
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.243-264
    • /
    • 2008
  • This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.

Flexural-torsional buckling tests of cold-formed steel compression members at elevated temperatures

  • Heva, Yasintha Bandula;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • v.14 no.3
    • /
    • pp.205-227
    • /
    • 2013
  • Current design standards do not provide adequate guidelines for the fire design of cold-formed steel compression members subject to flexural-torsional buckling. Eurocode 3 Part 1.2 (2005) recommends the same fire design guidelines for both hot-rolled and cold-formed steel compression members subject to flexural-torsional buckling although considerable behavioural differences exist between cold-formed and hot-rolled steel members. Past research has recommended the use of ambient temperature cold-formed steel design rules for the fire design of cold-formed steel compression members provided appropriately reduced mechanical properties are used at elevated temperatures. To assess the accuracy of flexural-torsional buckling design rules in both ambient temperature cold-formed steel design and fire design standards, an experimental study of slender cold-formed steel compression members was undertaken at both ambient and elevated temperatures. This paper presents the details of this experimental study, its results, and their comparison with the predictions from the current design rules. It was found that the current ambient temperature design rules are conservative while the fire design rules are overly conservative. Suitable recommendations have been made in relation to the currently available design rules for flexural-torsional buckling including methods of improvement. Most importantly, this paper has addressed the lack of experimental results for slender cold-formed steel columns at elevated temperatures.

Behaviour of steel joints under fire loading

  • da Silva, Luis Simoes;Santiago, Aldina;Real, Paulo Vila;Moore, David
    • Steel and Composite Structures
    • /
    • v.5 no.6
    • /
    • pp.485-513
    • /
    • 2005
  • This paper presents a state-of-the-art on the behaviour of steel joints under fire loading and some recent developments in this field, currently being carried out by the authors. Firstly, a review of the experimental research work on steel joints is presented, subdivided into isolated member tests, sub-structure tests and tests on complete building structures. Special emphasis is placed on the seventh Cardington test, carried out by the authors within a collaborative research project led by the Czech Technical University in Prague. Secondly, a brief review of various temperature distributions within a joint is presented, followed by a discussion of the behaviour of isolated joints at elevated temperature, focussing on failure modes and analytical procedures for predicting the moment-rotation behaviour of joints at elevated temperature. Finally, a description of the coupled behaviour of joints as part of complete structures is presented, describing previous work and investigations on real fire (including heating and cooling phases) currently being carried out by the authors.

Examining the Impact of Metaverse-Based Safety Education on Elementary School Students' Fire Safety Awareness (메타버스 활용 안전교육이 초등학생의 소방안전의식에 미치는 영향)

  • Hong - Sang Lee;Deok-Jin Jang;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.79-85
    • /
    • 2023
  • This study aims to verify the impact of a metaverse-based safety education program on the fire safety awareness of elementary school students. Utilizing the National Fire Agency's 119 metaverse program, an educational program was implemented for two months, and the experimental group was examined using paired-sample t-tests, while comparisons with the control group were made using independent-sample t-tests. The results revealed statistically significant differences between the experimental and control groups in the area of fire prevention. Although no statistically significant differences were observed over time within each group, the overall average scores for the entire class improved across all areas. Based on these findings, the effectiveness of metaverse-based safety education is suggested; however, a significant difference compared to traditional education was not detected. The study concludes by exploring implications for considerations in the implementation of metaverse safety education in the future.

The Estimation of Surface Temperature of Concrete Frame Caused by Fire (구체콘크리트면에 받는 열온도의 시뮬레이션 실험)

  • Nakagawa. Muneo;Kei. Yanagi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.272-277
    • /
    • 1997
  • The object of this paper is to analyze the surface temperature of RC structures caused by fire. The experimental analysis is undertaken by using following two methods. 1) Simulation to analyze the relationship between the temperature and the condition change for glass wool caused by fire. 2) Temperature-analysis (TG/DTA tests) of RC structures. From the results of the two experimental analysis, it was possible to estimate the temperature of RC concrete structures caused by fire.

  • PDF

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

Design of corrugated sheets exposed to fire

  • Sokol, Zdenek;Wald, Frantisek;Kallerova, Petra
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • This paper presents results of fire tests on corrugated sheets used as load bearing structure of roofs of industrial buildings. Additional tests of bolted sheet connections to the supporting structure at ambient and elevated temperatures are described. Three connection types were tested and their resistance, stiffness and deformation capacity was evaluated. Finite element simulations of the corrugated sheet based on the experimental observations are briefly described and design models are presented.