• Title/Summary/Keyword: experimental device

Search Result 2,839, Processing Time 0.032 seconds

Development of a Device for Estimating the Optimal Artificial Insemination Time of Individually Stalled Sows Using Direct-reflex Photo-sensors (직접반사형 포토센서를 이용한 스톨 사육 모돈의 인공수정적기 예측 장치 개발)

  • Kim D. J.;Yeon S. C.;Chang H. H.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.515-520
    • /
    • 2004
  • A device far estimating the optimal artificial insemination time consisted of a computer, RS module, and six direct-reflex photo-sensors. Program was written in LabWindows CVI. In order to establish references for estimating optimal artificial insemination time, lying rate of the thirty three $Berkshire{\times}Hampshire crossbred sows (parity 5 to 6) was recorded from 2 days after moving into stalls to artificial insemination using a time lapse VCR and was measured every hour with one minute interval using the scan point sampling method. Twenty low hours in a day were divided into three comparing periods : 21:00 to 06:59, 07:00 to 13:59, and 14:00 to 20:59. If sum of the percentages of tying during a comparing period was less than the reference value, the starting hour of the comparing period was considered as onset of estrus and the optimal artificial insemination time was estimated at 20 to 24 hours after onset of estrus. The experimental device was evaluated with twenty five $Berkshire{\times}Hampshire$ crossbred sows (parity 2 to 7) and 23 of 25 sows $(92\%)$ were pregnant. This result suggests that the experimental device is excellent in performance for estimating optimal artificial insemination time.

A Study of Prediction of Gas Transfer rate in Intravascular Lung Assist Device (혈관 내 폐 보조장치에서의 산소전달속도 예측에 관한 연구)

  • 김기범;나도춘;김성종;정인수;정경락;권대규
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.18-25
    • /
    • 2004
  • The purpose of this paper was to find out the proper equation to predict the gas transfer rate for designing intravenous artificial lung assist device. The prepared hollow fiber modules were examined under various experimental conditions through experimental modeling before inserted the artificial lung assist d $\varepsilon$ vice into as venous. As a result, we can estimate the gas transfer as a function of the packing density. The gas transfer obtained from the experiment was similar to that from the equation, confirming the usefulness equation. Therefore, we can conclude the gas transfer of the intravenous artificial lung assist device as a function of the packing density, and this functions are very useful for predicting the gas transfer of the intravenous artificial lung assist device.

Study on Dynamics Modeling of Pogo Suppression Device (PSD) (포고억제장치(PSD) 동특성 모델링에 관한 연구)

  • Lee, Jun-Kyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.5
    • /
    • pp.23-30
    • /
    • 2007
  • The effectiveness of a pogo suppression device (PSD) on the response of piping system simulating the propellant supply lines of the rocket engines was investigated experimentally by other researchers. In this study, the simplified analytical model was made, and the key parameters which are difficult to derive theoretically were identified in combination with the previous experimental work. In other words, the flow transient equations for a PSD system and the key parameters used to decide the instability of the system from the linearized transfer function including inertance, compliance, and resistance were derived. From the analysis, the values of key parameters could be determined from the experimental results.

Experimental investigation of a new steel friction device with link element for seismic strengthening of structures

  • Papadopoulos, Panikos K.;Salonikios, Thomas N.;Dimitrakis, Stergios A.;Papadopoulos, Alkis P.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.4
    • /
    • pp.487-504
    • /
    • 2013
  • In the present work a new friction device, with a set of single or double rotational friction flanges and a link element, is described and tested. The mechanism may be applied for the strengthening of existing r/c or steel buildings as well as in new constructed buildings. The device has selectable variable behavior in different levels of displacement and an interlock mechanism that is provided by the link element. The link element may be designed to lock at preselected level of displacement, offering in this way an extra safety reserve against strong earthquakes. A summary of the existing literature about other similar mechanisms is initially presented in this paper. The proposed mechanism is presented and described in details. Laboratory experiments are presented in detail and the resulted response that proves the efficiency of the mechanism at selectable levels of strength capacity is discussed. Drawings of the mechanism attached to a r/c frame with connection details are also included. Finally a dynamic analysis of two r/c frames, with and without the proposed mechanism attached, is performed and the resulted response is given. The main conclusion is that the proposed mechanism is a cheap and efficient devise for the improvement of the performance of new or existing framed buildings to seismic loads.

CHARACTERISTICS OF THE HETEROEPITAXIAL Si1-xGex FILMS GROWN BY RTCVD METHOD

  • Chung, W.J.;Kwon, Y.K.;Bae, Y.H.;Kim, K.I.;Kang, B.K.;Sohn, B.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S2
    • /
    • pp.84-89
    • /
    • 1995
  • The growth and the film characteristics of heteroepitaxial $Si_{1-x}Ge_x$ films growth by the Rapid Thermal Chemical Vapor Deposition(RTCVD)method are described. For the growth of $Si_{1-x}Ge_x$ heteroepitaxial layers, $SiH_4/GeH_4/H_2$gas mixtures are used. The growth conditions are varied to investigate their effects on the Si/Ge composition ratios, the interface abruptness and crystalline properties. The Si/Ge composition ratios are analyzed with the RBS and the SIMS techniques, and the interface abruptness are deduced from these data. The crystalline properties are analyzed from TEM pictures. The experimental data shows that the crystalline perfection is excellent at the growth temperature of as low as $650^{\circ}C$, and the composition ratios change linearly with $SiH_4/GeT_$$ gas mixing ratios in our experimental ranges. Boron doping experiments are also performed using 200 ppm $B_2H_6$ source gas. The doping profiles are measured with SIMS technique. The SIMS data shows that the doping abruptness can be controlled within about 200$\AA$/decade.

  • PDF

An Experimental Study of Pneumatic Damping at the Air Chamber for OWC type Wave Energy Device (OWC형 파력발전 공기챔버의 공기감쇠력 실험연구)

  • CHOI Hark-Sun;LEW Jae-Moon;HONG Seok-Won;KIM Jin-Ha
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.138-144
    • /
    • 2004
  • Pneumatic damping through a orifice type duct for OWC type wave energy device is studied experimentally. Forced oscillation tests are made to measure chamber pressure and velocity of air flaw through orifice. Pneumatic damping coefficient are deducted from the experimental research, and discussion are made far the influence of frequency, heave amplitude, and orifice size. Finally two formula are proposed for the estimation of non-dimensional pneumatic damping coefficient by regression analysis. The proposed formula proves to be a reliable method far practical application.

  • PDF

Effect of Wavy Flow of Vertical Falling Film on the Absorption Performance

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.3
    • /
    • pp.158-166
    • /
    • 2005
  • The present study investigated experimentally and numerically the enhancement of absorption performance due to the waviness of falling film in the vertical absorber tube. The momentum, energy and mass diffusion equations were utilized to find out temperature and concentration profiles at both the interfaces of liquid solution and refrigerant vapor and the wall. Flow visualization was performed to find out the wetting characteristics of the falling film. The maximum heat transfer coefficient was obtained for the wavy flow using spring as an insert device through both numerical and experimental studies. Based on the numerical and experimental results, the maximum absorption rate was found for the wavy-flow using spring as the insert device. The differences between experimental and analytical results ranged from $5.0\;to\;25\%\;when\;Re_j>100$.

An Experimental Study of Pneumatic Damping at the Air Chamber for an OWC-type Wave Energy Device (OWC형 파력발전 공기챔버의 공기감쇠력 실험 연구)

  • CHOI HARK-SUN;HONG SEOK-WON;KlM JIN-HA;LEW JAE-MOON
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.4 s.59
    • /
    • pp.8-14
    • /
    • 2004
  • Pneumatic damping through an orifice-type duct for an OWC-type wave energy device is studied experimentally. Forced oscillation tests are used to measure chamber pressure and velocity of air-flow through an orifice. Pneumatic damping coefficients are deducted from the experimental research, and the influence of frequency, heave amplitude, and orifice size are discussed. Finally, two formulas are proposed for the estimation of non-dimensional pneumatic damping coefficient by regression analysis. The proposed formula proves to be a reliable method for practical application.

An Experimental Study on Porous Air Bearing Stiffness Characteristics (다공질 공기 베어링의 강성 특성에 관한 실험 연구)

  • Jung, Soon-Chul;Lee, Seong-Hyuk;Lee, Jae-Eung;Ji, Hong-Kyu;Lee, Dong-Jin;Ryu, Je-Hyoung;Choi, Hyoung-Gil;Kim, Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.75-78
    • /
    • 2005
  • In this paper, an experimental study on porous air bearing stiffness for ultra precision positioning system was performed. In general manufacturer provide bearing stiffness under specific air pressure, but the air pressure used in the field is different. Therefore it is necessary to know the stiffness of air bearing under the pressure used in the field. In order to know that, experimental device which can realize actual operating conditions was made. Using this device, static and dynamic stiffness of air bearing can be obtained. As a result, displacement error occurred around 1 $\mu$m at recommended load.

  • PDF

Experimental Performance Evaluation of Token-Passing Mechanism in Foundation Fieldbus (Foundation Fieldbus에서 토큰-패싱 전송 방식의 실험적 성능 평가)

  • Bae, Jin-Woon;Hong, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.111-113
    • /
    • 2006
  • FOUNDATION fieldbus provides scheduling and token-passing services for cyclic and sporadic data respectively. In this paper, we evaluate the delay performance of token-passing mechanism in FOUNDATION fieldbus network system using an experimental model. This paper introduces a method of developing an experimental model which consists of 10 nodes of FOUNDATION fieldbus communication device. Using the experimental model, we evaluate the delay performance of time-critical and time-available data with respect to change of TTRT parameter.

  • PDF