• Title/Summary/Keyword: experimental device

Search Result 2,839, Processing Time 0.032 seconds

Numerical and experimental study of the nested-eccentric-cylindrical shells damper

  • Reisi, Alireza;Mirdamadi, Hamid Reza;Rahgozar, Mohammad Ali
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.637-648
    • /
    • 2020
  • In this study, a new steel cylindrical shell configuration of the dissipative energy device is proposed to improve lateral ductility and to reduce the damage of the structures against seismic forces. Four nested-eccentric- cylindrical shells are used to constructing this device; therefore, this proposed device is named nested-eccentric-cylindrical shells damper (NECSD). The particular configuration of the nested-eccentric-cylindrical shells is applied to promote the mechanical characteristics, stability, and overall performance of the damper in cyclic loads. Shell-type components are performed as a combination of series and parallel non-linear springs into the in-plan plastic deformation. Numerical analysis with respect to dimensional variables are used to calculate the mechanical characteristics of the NECSD, and full-scale testing is conducted for verifying the numerical results. The parametric study shows the NECSD with thin shells were more flexible, while devices with thick shells were more capacious. The results from numerical and experimental studies indicate that the NECSD has a stable behavior in hysteretic loops with highly ductile performance, and can provide appropriate dissipated energy under cyclic loads.

Cu Corrosion Test Method for Lead-Free Solders (무연솔더 동판부식 시험법 연구)

  • Kim, Mi-Song;Hong, Won Sik;Oh, Chul Min;Kim, Keun-Soo
    • Journal of Welding and Joining
    • /
    • v.35 no.3
    • /
    • pp.21-27
    • /
    • 2017
  • A soldering temperature of ($235{\pm}3$) $^{\circ}C$ is described in ISO 9455-15 for the copper corrosion test. However, this temperature is not suitable for performing lead-free solder pastes. We evaluated the compatibility of a lead-free solder paste in the experimental conditions of (Liquidus temperature + ($35{\pm}3$)) $^{\circ}C$. Based on the results after a Cu corrosion test, a proper temperature for Pb-free soldering was (melting point+($35{\pm}3$)) $^{\circ}C$. Criteria used to evaluate corrosion due to discoloration of flux residue is described in ISO 9455-15, but a more quantitative evaluation standard is needed. In this study, experimental error level was estimated by analyzing flux residue after a corrosion test for 72, 500 hours of specimens using EDS analysis with acceleration voltage. It was determined that the copper area at the flux residue boundary is suitable for the EDS analysis area.

The oxidation of silicon nitride layer (실리콘 질화막의 산화)

  • 정양희;이영선;박영걸
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.231-235
    • /
    • 1994
  • The multi-dielectric layer $SiO_2$/$Si_3{N_4}$/$SiO_2$ (ONO) is used to improve charge retention and to scale down the memory device. The nitride layer of MNOS device is oxidize to form ONO system. During the oxidation of the nitride layer, the change of thickness of nitride layer and generation of interface state between nitride layer and top oxide layer occur. In this paper, effects of oxidation of the nitride layer is studied. The decreases of the nitride layer due to oxidation and trapping characteristics of interface state of multi layer dielectric film are investigated through the C-V measurement and F-N tunneling injection experiment using SONOS capacitor structure. Based on the experimental results, carrier trapping model for maximum flatband voltage shift of multi layer dielectric film is proposed and compared with experimental data. As a results of curve fitting, interface trap density between the top oxide and layer is determined as being $5{\times}10^11$~$2{\times}10^12$[$eV^1$$cm^2$].

  • PDF

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

Design and Efficiency Analysis 48V-12V Converter using Gate Driver Integrated GaN Module (게이트 드라이버가 집적된 GaN 모듈을 이용한 48V-12V 컨버터의 설계 및 효율 분석)

  • Kim, Jongwan;Choe, Jung-Muk;Alabdrabalnabi, Yousef;Lai, Jih-Sheng Jason
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.201-206
    • /
    • 2019
  • This study presents the design and experimental result of a GaN-based DC-DC converter with an integrated gate driver. The GaN device is attractive to power electronic applications due to its superior device performance. However, the switching loss of a GaN-based power converter is susceptible to the common source inductance, and converter efficiency is severely degraded with a large loop inductance. The objective of this study is to achieve high-efficiency power conversion and the highest power density using a multiphase integrated half-bridge GaN solution with minimized loop inductance. Before designing the converter, several GaN and Si devices were compared and loss analysis was conducted. Moreover, the impact of common source inductance from layout parasitic inductance was carefully investigated. Experimental test was conducted in buck mode operation at 48 -12 V, and results showed a peak efficiency of 97.8%.

Experimental and analytical study of a new seismic isolation device under a column

  • Benshuai Liang;Guangtai Zhang;Mingyang Wang;Jinpeng Zhang;Jianhu Wang
    • Earthquakes and Structures
    • /
    • v.24 no.6
    • /
    • pp.415-428
    • /
    • 2023
  • Low-cost techniques with seismic isolation performance and excellent resilience need to be explored in the case of rural low-rise buildings because of the limited buying power of rural residents. As an inexpensive and eco-friendly isolation bearing, scrap tire pads (STPs) have the issue of poor resilience. Thus, a seismic isolation system under a column (SISC) integrated with STP needs to be designed for the seismic protection of low-rise rural buildings. The SISC, which is based on a simple exterior design, maintains excellent seismic performance, while the mechanical behavior of the internal STP provides elastic resilience. The horizontal behaviors of the SISC are studied through load tests, and its mechanical properties and the intrinsic mechanism of the reset ability are discussed. Results indicate that the average residual displacement ratio was 24.59%, and the reset capability was enhanced. Comparative experimental and finite element analysis results also show that the load-displacement relationship of the SISC was essentially consistent. The dynamic characteristics of isolated and fixed-base buildings were compared by numerical assessment of the response control effects, and the SISC was found to have great seismic isolation performance. SISC can be used as a low-cost base isolation device for rural buildings in developing countries.

Study on Ohmic resistance of Zn-doping InP using RTA method (RTA 방법에 의해 Zn 도핑된 InP의 오믹저항 특성연구)

  • Kim, H.J.;Kim, I.S.;Kim, T.U.;Kim, S.T.;Kim, S.H;Ki, H.C.;Lee, K.M.;Yang, M.H.;Ko, H.J.;Kim, H.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.237-238
    • /
    • 2008
  • Electrical properties of Pd/Zn/Pd/Au contacts to p-InP were investigated as function of the V/III ratio of p-InP. P-type InP was made by the Zn diffusion into InP and activation process with rapid thermal annealing (RTA) measurement. After activation, the hole concentration was two orders of magnitude higher than that of the sample having only diffusion process. According to transmission line method (TLM) results, the specific contact resistance of p-InP was lower as used InP having the lower V/III ratio. The experimental results represent that the diffusion of Zn in undoped InP deeply related to the equilibrium between interstitials and substitutional Zn is established via indium interstitials.

  • PDF

Assistant device development and effects for promotion of bag-valve-mask ventilation (백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과)

  • Kwon, Chan-Yang;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.

Nonpharmacological treatment of arrhythmia (소아 부정맥의 비약물적 치료)

  • Bae, Eun-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.930-936
    • /
    • 2006
  • Although antiarrhythmic medication has been the main treatment modality for arrhythmia in children, in recent decades technological development and computerization have made great advances in nonpharmacological therapy. This article reviews the transcatheter radiofrequency ablation for tachycardia in children, recent advances of device therapy for bradycardia, antitachycardia pacing, implantable cardioverter defibrillator. As a new field of device therapy, cardiac resynchronization therapy for congestive heart failure is also mentioned.

Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter (발효기 하드웨어 변환을 이용한 용존산소 제어)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF