• Title/Summary/Keyword: experimental apparatus

Search Result 1,175, Processing Time 0.025 seconds

Manufacture of Precsion Model Using Laser Melting Process (레이저 용융 적층 공정을 이용한 정밀 형상 제작)

  • 김재도;전병철;권택열;이영곤;신동훈
    • Laser Solutions
    • /
    • v.3 no.3
    • /
    • pp.21-29
    • /
    • 2000
  • For the direct metal shape processing the powder feed device which is different from the widely used in rapid prototyping. is developed, The three dimensional object is shaped with the melting metal powder. The developed research has applied to rapid prototyping in ultraprecision for MEMS and medical science fields required of rapid manufacture of complex shape. The goal of this study make 3D model which has precision accuracy. Powder spreading apparatus has been more improved because that the control of powder spread is very important in layer manufacturing. It consists of the vibration motor, nozzle and tube which supplies various metal powder. This apparatus could control the spreading velocity that could control powder spreading thickness. Laser on/off switch was adapted because laser scanning velocity must be preserved constantly to prevent heat transformation of laser overheating. The error between sintered thickness md experimental one occurred by shrinkage in sintering melting process. The problem of heat transformation was solved by On/Off switching system.

  • PDF

Modelling of a Biomolecular Processing for the Production and Secretion of Monoclounal Antibody (단일콜론항체 생산 및 분비에 대한 생물분자공정의 모델링)

  • 박재성;박선호
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.369-377
    • /
    • 1998
  • To analyze the unique aspects of biomolecular processing for monoclonal antibody (MAb) production and secretion, the simple working model based on 3-compartment (endoplasmic reticulum, Golgi apparatus, and extracellular medium) was developed. Based on in vitro MAb assembly experimental results, the kinetic model for MAb assembly in the endoplasmic reticulumn was proposed. The dynamics of MAb assembly and secretion was simulated using methematica program. According to the simulation results, the proposed 3-compartment model provides an efficient means to predict the specific MAb productivity as well as intracompartmental concentrations of MAb in endoplasmic reticulum, Golgi apparatus, and extracellular compartment model. In vivo profiles of MAb intermediates gave good agreements with the simulation profiles predicted by the intracellular compartment model. Furthermore, results of such analysis can help in directing the control strategy for optimum biomolecular processing in a mammalian cell culture system.

  • PDF

A Study on the UHF PD Sensor and Novel Pattern Analysis Technology for Diagnosis of the High Power Apparatus (초고압 전력기기 진단을 위한 UHF PD 센서 및 패턴분석 기술에 관한 연구)

  • 강원종;이창준;강윤식;이희철;박종화
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.83-90
    • /
    • 2004
  • This paper describes investigations of the UHF(Ultra High Frequency) PD(Partial Discharge) measuring technology designed for monitoring of PD in high power apparatus. Based on the spiral antenna theory, the hole type sensor for GIS with metal flange spacer and injection type sensor for oil filled transformer are developed. The experimental results show measurement characteristics of the PD sensor for several artificial defects in gas-insulated system(GIS) and oil transformer. Moreover, we proposed the new $\phi$-f-q method for the purpose of condition assessment of high power apparatus.

Research on Comparison of Individual and Connecting Grounding Electrode for Potential Rise Distribution (개별 접지전극과 연접된 접지전극의 전위상승 분포 비교 연구)

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • This paper deals with a comparison of individual and connecting grounding electrode for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. In order to analyze the potential rise of grounding systems, a hemispherical water tank experimental apparatus was studied. Potential rise was measured and analyzed regarding the grounding method and distance by using this apparatus. The apparatus was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by the horizontal moving probe of the potentiometer. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding electrode were higher than those of connecting grounding electrode. The distributions of surface potential are dependent on the distance from grounding electrode.

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

A Study on the Solid-liquid Equilibria for Benzene+aniline, Benzene+nitrobenzene, p-xylene+cyclohexane (Benzene+aniline, benzene+nitrobenzene, p-xylene+cyclohexane계의 고액평형에 관한 연구)

  • Park, So-Jin;Paik, Seung-Kwan
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.864-869
    • /
    • 1998
  • In this work, the solid-liquid equilibria (SLE) of some aromatic organic mixtures including benzene, widely used as an industrial solvent, were measured by static method using our own made experimental apparatus. The accuracy and reproducibility of apparatus were tested by comparing experimental results with literature values for 1-dodecanol+cyclohxane and benzene + p-xylene systems. The SLE for new binary systems of benzene+aniline, benzene+nitrobenzene, p-xylene+cyclohexane were measured afterwards and compared with the calculated values by modified UNIFAC(Dortmund) equation.

  • PDF

A Study on Strip Fabrication Processes Using Mushy State Rolling(I) (반용융 압연을 이용한 박판제조공정에 관한 연구( I ))

  • 백남주;강충길;김영도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.584-595
    • /
    • 1991
  • In the direct rolling processes for the mushy state alloy, a mushy state material which simultaneously contains liquid-solid phase is obtained from the exit port of stirring apparatus with a given solid fraction. This solid fraction is dependent on the temperature of within the solid-liquid range which shows to be controlled accurately by the experimental conditions for a given stirring apparatus. Rolling conditions for fabrication the fine surface strip were obtained from direct rolling experiment with mushy state alloys of Sn-75%Pb and aluminum alloy. Influence of solid fraction, rolling speed and initial roller gap on the state of strip surface and solidified structure was observed. We proposed theoretical model for prediction of rolling force, and we compared calculation result and experimental value measured with load cell.

Reaction of Ankle Muscles by Functional Electrical Stimulation (기능적 전기 자극에 의한 족관절 근육 반응)

  • Jung, S.I.;Oh, S.H.;Kim, J.O.;Park, K.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • This paper deals with an experimental study on the reaction of muscles by functional electrical stimulation(FES) with the design and fabrication of an ankle reaction apparatus. The ankle reaction apparatus consists of a circuit part and a kinematic part, and it monitors reaction time for a particular angle of joint rotation according to FES. The experimental results showed that the change of the ankle rotation angle was linearly proportional to the change of the magnitude of FES. It also showed that the muscle's reaction time was constant no matter how large the magnitude of the stimulus. The results of this paper can be applied to develop an active-type walking-assistance robot.

Measurement and Prediction of Autoignition Temperature(AIT) of Flammable Substances - Methanol and Ethanol - (가연성물질의 자연발화온도 측정 및 예측 - 메탄올과 에탄올 -)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.54-60
    • /
    • 2004
  • Flammable substances are frequently used chemical industry processes. An accurate knowledge of the ALTs(Autoignition Temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, ignition delay. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for methanol and ethanol. The A.A.P.E.(Average Absolute Percent Error) and the A.A.D.(Average Absolute Deviation) of the experimental and the calculated delay times by the AITs for methanol were 14.59 and 1.76 respectively. Also the A.A.P.E. and the A.A.D. of the experimental and the calculated delay times by the ATIs for ethanol were 8.33 and 0.88.

A Study on the In-process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Laser Beam (원통연삭가공시 레이저 빔을 이용한 금속 표면거칠기의 인프로세스 측정에 환한 연구)

  • 김희남;윤여권;이주상;김대욱
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.3
    • /
    • pp.41-52
    • /
    • 1994
  • This paper deal with the design of noncontact In-process measurement system which measures the surface roughness during cylindrical grinding. The measuring system is extremely simple and the apparatus proposed is composed of a laser unit, photodetector and optical system. The experimental performance of the apparatus is satisfactory and good results are expected in the actual use. During operation, the surface of a workpiece Is continuously scanned by a laser beam. The experimental results show that the presence of chattering, loading and glazing can be detected sensitively along both circumferential and feed directions and the surface roughness value is obtained from the reading along the feed direction.

  • PDF