• 제목/요약/키워드: experimental apparatus

검색결과 1,175건 처리시간 0.029초

BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거 (Nutrient Removal in an Advanced Treatment Process using BIO-CLOD)

  • 박완철;이미애;성일화
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

새로운 Tension Split Hopkinson Bar를 이용한 박판의 고속 인장시험 (High strain rate tensile test of sheet metals with a new tension split hopkinson bar)

  • 강우종;조상순;허훈;정동택
    • 대한기계학회논문집A
    • /
    • 제21권12호
    • /
    • pp.2209-2219
    • /
    • 1997
  • A split hopkinson bar could be used for obtaining the high strain rate material properties of sheet metals for an autobody. In high speed tensile tests of sheet matals, a new design of a tension split Hopkinson bar apparatus is needed. The design of grips and an anvil length are numerically analyzed with ABAQUS/Explicit for the new apparatus of split Hopkinson bars. From the experiments with the new apparatus, the material properties of SPCEN in the high strain rate state have been acquired and compared with quasi-static experimental results. The material properties of SPCEN as well as other sheet metals in an autobody are indispensible for the analysis of crashworthness. Nevertheless the experiment of sheet metal in the high strain rate state has not been done or reported.

액중 방전 성형의 실험 장치 개발 및 실험적 연구 (Development of Electrohydraulic Forming Apparatus and Its Experimental Study)

  • 우민아;노학곤;송우진;강범수;김정
    • 한국자동차공학회논문집
    • /
    • 제25권2호
    • /
    • pp.236-241
    • /
    • 2017
  • Electrohydraulic forming is a high-speed forming process that deforms a blank using electric discharge in liquid. When high voltage is discharged in the water, a shock wave is propagated from the tip of the electrodes to the blank, causing the blank to be deformed into the die. Electrohydraulic forming has many advantages including improved formability and reduced bouncing effect and springback. The objective of this paper was to conduct a feasibility study to identify the electrohydraulic effect. An electrohydraulic forming apparatus was developed and experiments were carried out. The results of the experiment showed that the developed apparatus had sufficient energy to deform the blank into the die. Using the hole to emit residual air in the die was more effective than using the vacuum pump in terms of saving on experiment time.

KS L 9107에 의한 태양열 취득률(SHGC) 측정장치 개발 및 평가 (Development and Evaluation of an Apparatus to Measure the Solar Heat Gain Coefficient of a Fenestration System According to KS L 9107)

  • 김태중;최현중;강재식;박준석
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.512-521
    • /
    • 2014
  • Recently, multiple glazing units, frames, complex fenestration systems, and windows with shading devices have been developed to save cooling energy in buildings. However, very little work has been conducted on developing a direct experimental test method of the solar heat gain coefficient(SHGC) for new fenestration techniques. This study aims to develop and evaluate a test apparatus to measure the SHGC, according to the KS L 9107 test method. The performance of the solar simulator was class A, B, and A, for spectral match, non-uniformity, and instability irradiance, respectively. The differences between the measured and calculated SHGC values were found to range between 0.001 and 0.011, and for all test specimens they agreed within 4%. These results establish the validity of the test apparatus. This system is thus expected to be useful in assessing the energy performance for various types of fenestration.

클리브랜드 개방식 장치를 이용한 2-propanol+acid류 계의 하부 인화점 측정 및 예측 (The Measurement and Estimation of Lower Flash Point for 2-Propanol+Acid Systems Using Cleveland Open Cup Apparatus)

  • 하동명;이성진
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.32-37
    • /
    • 2007
  • 인화점의 정보를 확보하는 것은 화재 및 폭발의 예방을 위해 대단히 중요하다. 본 연구에서는 2-propanol+acetic acid 계와 2-propanol+n-propionic acid 계의 하부 인화점을 클리브랜드 개방식 장치를 이용하여 측정하였다. 실험값은 Raoult의 법칙, Wilson 식과 NRTL 식에 의해 계산된 값과 비교하였다. 그 결과, Wilson 식과 NRTL 식에 의한 예측값이 Raoult의 법칙에 의한 예측값 보다 실험값에 더욱 근접하였다. 또한, NRTL 식의 실험값에 대한 모사성이 Wilson 식의 그것 보다 우수하였다.

중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

160% 피치의 유로에서 단일익형에 의한 캐스케이드 실험을 위한 벽면의 설계에 관한 연구 (A Study of Design of Sidewalls for Cascade Model with Single Blade Within a 160% Pitch Passage)

  • 조종현;김영철;안국영;조수용
    • 한국항공우주학회지
    • /
    • 제37권6호
    • /
    • pp.527-536
    • /
    • 2009
  • 캐스케이드 실험장치에 한 개의 익형을 설치하여 캐스케이드 실험이 가능한 장치벽면의 설계를 수행하였다. 장치의 폭은 피치의 160% 넓이이다. 이 경우에 실험장치 내에 다수개의 블레이드를 설치하는 경우에 비하여 소형의 장치라도 실험의 정확성이 향상되는 장점이 있지만, 피치방향으로 주기조건을 맞추기가 어렵다. 본 연구에서는 주기조건이 얻어지도록 벽면의 형상설계를 내부유동장의 결과를 바탕으로 기울기기반과 유전자알고리즘의 방식을 사용하여 벽면을 설계하였다. 이를 위하여 목적함수는 캐스케이드 익형의 표면에서 얻어진 마하수를 적용하였으며, 실험장치의 형상 조정이 가능한 14개의 설계변수를 적용하였다. 유전자알고리즘에 의한 최적화 설계방식이 향상된 결과를 보여주었다.

고온초전도 기기를 위한 극저온 액체 중 절연물의 전기적 특성 (Electrical Insulation Characteristics of Insulators in Cryogenic Liquid for a HTS Apparatus)

  • 백승명;곽동순;천현권;최재형;김상현;김현희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.263-264
    • /
    • 2006
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of insulators in cryogenic liquid such as liquid nitrogen ($LN_2$) is essential. So in this paper, we discussed experimental investigations of breakdown and V-t characteristics of several insulators such as Kapton and glass fiber reinforced plastic (GFRP) that are candidates of insulator for HTS apparatus in cryogenic liquid. And we investigated the degradation of these insulation samples after breakdown with the microscope and SEM photograph. Moreover, survival and hazard analysis were performed.

  • PDF

이상계 혼합기에서의 분진운의 공간분포에 대한 평가 (Evaluation for Space Distribution of Dust Cloud in Hybrid Mixtures)

  • 한우섭;정국삼
    • 한국안전학회지
    • /
    • 제10권1호
    • /
    • pp.35-40
    • /
    • 1995
  • This study dealed with problem to estimate the uniformity of dust clouds, as a fundamental study to estimate the ignition hazardous evaluation of hybrid mixtures. The developed method was proposed to grasp space distribution of dusts, and also, an experimental apparatus considering with dispersion and reproduction of dusts were uniquely devised and studied.

  • PDF