• Title/Summary/Keyword: expected life time

Search Result 669, Processing Time 0.027 seconds

The Hospital Life of the Patient with Femoral Neck Fracture (대퇴경부 골절 환자의 입원 생활)

  • Kim, Kyung-Ja;Chi, Sung-Ai
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.35-56
    • /
    • 1996
  • Nowerdays, the increase of traffic accidents and old age population make the Femoral Neck Fracture(FNF) patients increase. By the improvement of education and standard of living the patients demand better medical service than before. This study is designed to give practical help for the FNF patients by observing their hospital life and establish practical nursing strategies for the FNF patients. For these purposes the Ethnographic Participant Observation was adopted. By this study is focused on the hospital life patient's view. For this end, the field study adopted orthopedic ward in the C University Hospital with 400 beds in Seoul. The object patients of the study were twelve patients. The patients experienced five stages : Embarrassment, Conflict, Stability, Independent, and Extension Stage. The findings and prepared nursing strategies are stated as follows. First, in the Embarrassment Stage they suffered embarrassment, anxiety, pain, they could not do ordinary things. The patients who accidental fractures had anxiety from unfamiliar tests and from hospitalization itself. They lamented that they could not ordinary things, and do nothing but obeying the hospital, and endure the pain. They recognized the changed environment and resigned themselves to life in the ward. In this stage, full openness by the nurses is needed. Second, the attribute of the Conflict Stage were conflict, fear, curiosity, belief, reflection. When they sign the consentment form, they experience conflicts about the possibility of complication, fear of recovery from anesthesia, curiosity about the operation procedure, post - operation state, reflection on their past life, and promise to care for their family members after discharge and keep their religious life faithfully. And they accepted the operation depending on God, believing in modern medicine, and the surgeon. Asking for their changed informations, they expected positive results from the operation. In this stage, an empathic attitude by the nurses is needed. Third, the attribute of the Stability Stage were relief, gratitude, difficulty with excretion, and pain. When they awoke from anesthesia, they felt relief because of a the end of the operation, but they experienced extreme pain, difficulty of excretion in bed. They accepted the changed environment and expected recovery. In this stage, support by the nurses is needed. Fourth, the attributes of the Independence Stage were freedom, exercise, nurturing, anxiety, and discomfort. When they ambulated and exercised, they experienced freedom. They showed exhibited weakness of the digestive organs and discomfort hospital's space, structure, and facilities, the delay of medical certificate issue the lack of prompt response by the medical agents. They ate nurturious food and felt anxiety on the end of hospital life and returning to their ordinary life. They showed the independence of overcoming their environment by increasing exercise and expected their discharges. In this stage, respect by the nurses is needed for the patients to, overcome their environment and prepare for their independence. Fifth, the attributes of the Extension Stage were pessimism, isolation, dissatisfaction, and pain. Accompanied injury and old age made their ward life extend to over seven weeks. They exhibited weariness, melancholy, skeptisis, general pessimistic feeling, and desperation caused by their isolated life. They experienced the digestive discomfort caused by the prolonged medication and psycological pain caused by long-time hospitalization. As a, result, their dissatisfaction on the human, physical, and systematic environments had been increased. They acquired critical power and sought for something to do spending their time. They expected vaguely about the returning of their ordinary life. In this stage, counseling is needed by the nurse to overcome positively their psychological, social, and physical problems. The process of the FNF patient's ward life starts from the dependent state, when they are hospitalized, and gradually progresses to self-fulfillment in order to keep independent life. As a result, the FNF patients showed "Response in Challenge" or "Adaptation in Conflict" through their experiences of social, physical, and psychological difficulties.

  • PDF

A Study on the Form of Settlement in Bronze Age Based on Jangheung Sinpoong-ri Site (장흥(長興) 신풍리(新豊里) 청동기시대(靑銅器時代) 취락(聚落)의 정주형식(定住形式)에 관한 연구(硏究))

  • Shin, Sang-Hyo;Cheon, Deuk-Youm
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.73-81
    • /
    • 2007
  • Remains of settlement are important sources of information in understanding the life style of the time and restoring it. This paper analyzed and studied the residential lives of the time including location of settlement, form and size, interior and change patterns based on Jangheung Sinpoong-ri Site. This study will have a meaning in that it deals with settlement in community well beyond the scope of previous studies which focused on settlement in small sizes and is expected to be a principle one about human residential structure.

Time Dependent Extension and Failure Analysis of Structural Adhesive Assemblies Under Static Load Conditions

  • Young, Patrick H.;Miller, Zachary K.;Gwasdacus, Jeffrey M.
    • Journal of Adhesion and Interface
    • /
    • v.21 no.1
    • /
    • pp.6-13
    • /
    • 2020
  • The objective of the current study is to characterize the long-term stability and efficacy of a structural adhesive assembly under static load. An apparatus was designed to be used in the Instron tensile test machine that would allow for real time modeling of the failure characteristics of an assembly utilizing a moisture- cure adhesive which was bonded to concrete. A regression model was developed that followed a linear - natural log function which was used to predict the expected life of the assembly. Evaluations at different curing times confirmed the structure was more robust with longer cure durations prior to loading. Finally, the results show that under the conditions the assembly was tested, there was only a small amount of inelastic creep and the regression models demonstrated the potential for a stable structure lasting several decades.

Optimization of RAPD-PCR Conditions for Onions, Allium cepa L. (양파(Allium cepa L)의 RAPD 분석조건 최적화에 관한 연구)

  • 정순재;양보경;김익수;박선희;서전규;남재성;김현경;김도훈
    • Journal of Life Science
    • /
    • v.10 no.2
    • /
    • pp.182-187
    • /
    • 2000
  • The optimized RAPD-PCR conditions, which can be utilized as a basic information for the analysis of the genetic characteristics were investigated with four onion varieties, named Changryungdaego, Yeoeuijuhwang, Yakwangju, and Dabonghwang using Operon primers, OPR01 (TGCGGGTCCT) and OPZ20 (ACTTTGGCGG). We tested several concentrations of DNA, primer, and MgCl2, annealing temperature, number of PCR cycle, and presence/absence of pre-heating time at the begining of PCR reation in the 25${mu}ell$ volume. The best RAPD profiles were obtained using 50ng of DNA, 5mM of primer, 1.5mM of MgCl2, 45$^{\circ}C$ of annealing temperature and an absence of pre-heating time. An establishment of the stable and reproducible RAPD-PCR conditions are expected to be useful for the subsequent RAPD-related investigation, such as genetic characterization of the onion strains, re-establishment of phylogenetic relationships and development of new varieties.

  • PDF

Study on target erosion in rocking magnet sputtering system

  • Lee, Do-Sun;Kwon, Ui-Hui;Lee, Won-Jong
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.245-251
    • /
    • 2005
  • A high performance dual rocking magnet sputtering gun has been developed. The rocking magnet sputtering gun introduces full-face erosion by rapidly rocking the magnet in the region where the high plasma density is maintained. The newly developed dual rocking magnet sputtering gun whose target utilization was 77 percent achieved high performance in quality in the view of target utilization and target life-time comparing to the existing magnetron sputtering gun. The PIC-MCC target erosion simulation has been performed simultaneously. Comparing experimental target erosion profiles with simulated target erosion profiles, the simulation could estimate the tendency of the target erosion profiles but could not estimate an exact target erosion profile. If the simulation were improved more precisely, the cost reduction for the development of the multiple rocking magnet sputtering gun would be expected.

A Study on the Failure Analysis and Performance Improvement of a Decanter (디칸터의 고장분석 및 성능 향상에 관한 연구)

  • Shin, Chang-Ho;Lee, Dong-Chul;Kim, Woo-Hyung;Choi, Tae-Ju;Chung, Jin-Tai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.586-592
    • /
    • 2004
  • In this study, the failure analysis of a decanter is carried out and the methods of performance improvement are presented. The decanter is a centrifugal separator that is used to separate water and solids from municipal and industrial sludge. Therefore, the decanter should be designed to improve the dewatering of sludge. Besides high performance, the decanter should guarantee its life time under a severe using condition. For theses reasons, the failure analysis and performance improvement of the decanter are studied. It is found from this study that the failure is caused by mass unbalance, wear, clogging or crack. If these failure causes are prevented, the life time as well as the performance is expected to be improved.

Reliability Analysis of Power Conversion System by Test Environments (시험환경에 따른 전력변환장치의 신뢰성 분석 및 검토)

  • Lim, Jong-ung;Yoon, Chun-gi;An, Yoon-Young;Lim, Yong-Bae;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.39-40
    • /
    • 2016
  • Power conversion system comes with a twenty-year warranty commonly. Life test requires a long time. The life of power conversion system that especially sensitive to temperature can be expected within a short time by using Arrhenius technique with worst stress condition than actual working condition. This paper researches reliability analysis and environment test of power conversion system.

  • PDF

A study on the accommodation of common LED to shipboard (육상용 LED 램프의 선박 적응력에 관한 연구)

  • Jeong, Ji-Hyun;Park, Hwan-Chul;Kim, Yong-Joo;Seo, Sang-Do;Han, Seung-Jae;Kim, Min-Sok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

A Study on Life Time Prediction of ACM Rubber Composite Using Accelerated Test and Thermogravimetric Analysis (노화촉진시험법 및 TGA를 이용한 ACM 고무복합재료의 수명 예측 연구)

  • Ahn, WonSool;Lee, Joon-Man;Lee, Hyung Seok
    • Elastomers and Composites
    • /
    • v.49 no.2
    • /
    • pp.144-148
    • /
    • 2014
  • Compression set (CS) and weight loss by thermal degradation of the ACM rubber composite sample prepared for an automotive part were measured simultaneously at several given temperatures of $150^{\circ}C$, $160^{\circ}C$, $170^{\circ}C$, and $180^{\circ}C$. Using the relationship between them, thermal life of the sample could be predicted at a given operating temperature by applying Toops method which is based on the analysis of non-isothermal TGA thermograms. Conversion by weight loss showed a linear relationship with CS changes, exhibiting 4.2% at CS 40%. Activation energy of thermal degradation was calculated as 120.2 kJ/mol at 4.2% of weight loss from Flynn-Wall-Ozawa analysis. When the expected life was set as time to reach CS 40% at $120^{\circ}C$, the life time of the sample was calculated as 9,700 hrs when Toops method was applied.

Service Life Prediction of Rubber Bushing for Tracked Vehicles

  • Woo, Chang-Su;Kang, In-Sug;Lee, Kang-Suk
    • Elastomers and Composites
    • /
    • v.55 no.2
    • /
    • pp.81-87
    • /
    • 2020
  • Service life prediction and evaluation of rubber components is the foundational technology necessary for securing the safety and reliability of the product and to ensure an optimum design. Even though the domestic industry has recognized the importance thereof, technology for a systematic design and analysis of the same has not yet been established. In order to develop this technology, identifying the fatigue damage parameters that affect service life is imperative. Most anti-vibration rubber components had been damaged by repeated load and aging. Hence, the evaluation of the fatigue characteristics is indispensable. Therefore, in this paper, we propose a method that can predict the service life of rubber components relatively accurately in a short period of time. This method works even in the initial designing stage. We followed the service life prediction procedure of the proposed rubber components. The weak part of the rubber and the maximum strain were analyzed using finite element analysis of the rubber bushing for the tracked vehicles. In order to predict the service life of the rubber components that were in storage for a certain period of time, the fatigue test was performed on the three-dimensional dumbbell specimen, based on the results obtained by the rubber material acceleration test. The service life formula of the rubber bushing for tracked vehicles was derived using both finite element analysis and the fatigue test. The service life of the rubber bushing for tracked vehicles was estimated to be about 1.7 million cycles at room temperature (initial stage) and about 400,000 cycles when kept in storage for 3 years. Through this paper, the service life for various rubber parts is expected be predicted and evaluated. This will contribute to improving the durability and reliability of rubber components.