• Title/Summary/Keyword: expansion tube

Search Result 292, Processing Time 0.026 seconds

Design of Large Capacity Clean Air Heater (대용량 청정 공기 가열 장치 설계)

  • Kim, Jeong-Woo;Jung, Kwang-Soo;Jeon, Min-Joon;Lee, Kyu-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.115-118
    • /
    • 2010
  • 2 Types of heater (Vitiated Type, Clean Air Type) in order to increase the temperature for a test are used for industry. In this report, large capacity clean air type heater was designed. Heater capacity and LNG consumption rate can be calculated by the air mass flow and heater inlet/outlet temperature. The heater is composed by Burner, Furnace, Heat Exchanger, and Stack. The hot air from the burner and cold air from the tube inlet exchange their heat indirectly in the heat exchanger, so the desired temperature can be achieved at the exit of the tube.

  • PDF

An assessment of friction factor and viscosity models for predicting the refrigerant characteristics in adiabatic capillary tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.47-54
    • /
    • 2008
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses, and flashing, simultaneously. In this paper flow characteristics of adiabatic capillary tubes with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models were simulated. The predicted pressure distribution, mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing the suitable correlations of friction factor and two-phase viscosity model, and two-phase frictional multiplier.

  • PDF

The Design of Rear Suspension Using Hydroforming (하이드로포밍을 이용한 후륜 현가장치 설계)

  • Oh, J.H.;Choi, H.H.;Lee, G.M.;Park, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.205-208
    • /
    • 2008
  • Generally, there are several types in rear suspension. The rear suspension of subframe type consisting of side member and front/rear cross member is widely used in a medium car and full car. In the small car case, the beam of tubular type without independent suspension system is used to reduce manufacturing cost. The optimized rear suspension of subframe type using hydroforming method has been developed in this study. In designing suspension, the driving stability and durability performance should be considered as an important factor. The stability is related to dynamic frequency and durability is connected with stress analysis of structure. We focus on increasing the stiffness of suspension and decreasing the maximum stress relating to durability cycle life. For making use of the merits of hydroforming which is possible to make the bead, tube expansion, and feeding in desiring position, several optimization design techniques such as shape, size, and topology optimization are proposed. This optimization scheme based on the sensitivity can provide distinguished performance improvement in using hydroforming. Through commercial software based on the finite element, the superiority of this design method is demonstrated.

  • PDF

Analysis of Acoustical Performance of Exhaust System by Lattice Filter (격자필터에 의한 배기계의 소음특성 해석)

  • Hwang, Won-Gul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.5
    • /
    • pp.126-135
    • /
    • 1995
  • An exhaust muffler is one of the simple and effective means to meet the demand for a quiet vehicle, and it deserves a close attention to effectively reduce the engine noise. The transfer function technique is one of the tools that have been used to analyze the noise characteristics of the exhaust muffler. In this paper we obtained a transfer function using the forward-going and backward-going components of sound pressure in the exhaust muffler, which is compatible wiht lattice filter algorithm. This form of transfer function is obtained for the basic elements of a muffler, such as uniform tube, open termin- ation, closed termination, anechoic termination, expansion, contraction, extended-tube resonator, hole, Helmholtz resonator, and concentric hole-cavity resonator. The results are combined to produce the transfer function of various types of mufflers. With this transfer function we calculate the transmission and insertion losses of mufflers, and examined the effects of various design parameters. Comparisons were made between the calculation and experimental results, which showed a good agreement, and we conclude that the transfer function of lattice form can be used to analyze the noise characteristics of the exhaust mufflers.

  • PDF

Preparation process of functional particles: II. Particle coating by rapid expansion of supercritical fluid solutions (기능성 미분말의 제조공정에 관한 연구: II. 초임계 분출법에 의한 입자 코팅)

  • 류완원;김영도;신건철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.673-676
    • /
    • 1998
  • The Rapid Expansion of Supercritical fluid Solutions (RESS) process was applied to particles coating. Experiments were conducted in a fluidized bed with an internal nozzle in the center of the reaction tube. Pure glass beads (500~590$\mu$m, 74~149$\mu$m) and glass beads covered with brilliant blue were used as the core particles. Supercritical $CO_2$ solutions of paraffin were expanded through the nozzle into the bed that was fluidized by air. The precipitate coating materials on core surface was analyzed by using SEM, FT-IR. The releasing behavior of brilliant blue was inspected by atomic absorbance spectrophotometer. The release behavior of coated particles superior to noncoated particles.

  • PDF

Evaporator Superheat Control of a Multi-type Air-Conditioning/Refrigeration System (멸티형 공조/냉동시스템의 증발기 과열도 제어)

  • 김태섭;홍금식;손현철
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.253-265
    • /
    • 2001
  • This paper investigates a PI control problem for the evaporator superheat, i.e., temperature difference between the two-phase region and the exit region of an evaporator, for multi-type air-conditioning/refrigeration system. Mathematical model describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, two transfer function from the current input applied to an electronic expansion valve to the wall-temperatures of an evaporator tube at two-phase region and superheated region, respectively, are derived. The stability of the closed loop system with the PI controller designed it analyzed by using Nyquist stability criterion. Simulation results are provided.

  • PDF

Effects of Accumulator Heat Exchangers on the Performance of a Refrigeration System (열교환기 내장형 어큐물레이터가 냉동시스템의 성능에 마치는 영향에 관한 연구)

  • Kang, Hoon;Choi, Kwang-Min;Park, Cha-Sik;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.433-438
    • /
    • 2005
  • An AHX(Accumulator Heat eXchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure the liquid-phase refrigerant entering into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using H-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the installation of AHX were quite different from those without the installation of AHX. Therefore, it is required to find an optimum refrigerant charging amount and optimum operating conditions, when AHX is installed in the refrigeration system with an fixed area expansion device such as a capillary tube.

  • PDF

AN EXPERIMENTAL STUDY ON HARDNESS IN COMPOSITE RESINS (수종복합레진의 경도측정에 관한 실험적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.4 no.1
    • /
    • pp.35-38
    • /
    • 1978
  • The purpose of this study was to measure micro-knoop hardness and coefficient of thermal expansion on composite resins (Epolite, Adaptic, Hipol and Compo T.) Four different type of composite resins were measured at the varying depth of 30, 60, 90, 150, 200, 400, 700 and 1000 micron from the surface to deep portion. The specimens were stored both in the air room temperature for 2 days, 30 days and in water at $37^{\circ}C$ for 30 days. Thermal expansions of specimens(4mm in diameter and 50mm in height) were measured in quartz tube dilatometer from $20^{\circ}$ to $70^{\circ}C$ The following results were obtained. 1. The hardness of superficial portion were lower than inner portion of resin. 2. The value of hardness obtained from the specimen stored in room temperature in the water at $37^{\circ}C$ for 30 days were lower than above described Cases. 3. The coefficient of thermal expansion of Adaptic had $29.75{\times}10^{-6}/^{\circ}C$, Hipol had $30{\times}10^{-6}/^{\circ}C$, Epolite had $39.85{\times}10^{-6}/^{\circ}C$ and Compo T had $36.95{\times}10^{-6}/^{\circ}C$.

  • PDF

Effects of Accumulator Heat Exchanger on the Performance of a Refrigeration System (열교환기 내장형 어큐뮬레이터가 냉동시스템의 성능에 미치는 영향에 관한 연구)

  • Kang Hoon;Choi Kwang-Min;Park Cha-Sik;Kim Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.418-425
    • /
    • 2006
  • An AHX (Accumulator Heat exchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure that liquid-phase refrigerant enters into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using R-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the AHX are considerably different from those without the AHX. Therefore, it is required to determine optimum refrigerant charge and optimum operating conditions when the AHX is used in the refrigeration system having a constant flow-area expansion device such as capillary tube.

An improved model of compaction grouting considering three-dimensional shearing failure and its engineering application

  • Li, Liang;Xiang, Zhou-Chen;Zou, Jin-Feng;Wang, Feng
    • Geomechanics and Engineering
    • /
    • v.19 no.3
    • /
    • pp.217-227
    • /
    • 2019
  • This study focuses on an improved prediction model to determine the limiting grouting pressure of compaction grouting considering the ground surface upheaval, which is caused by the three-dimensional conical shearing failure. The 2D-dimensional failure curve in Zou and Xia (2016) was improved to a three-dimensional conical shearing failure for compaction grouting through coordinate rotation. The process of compaction grouting was considered as the cavity expansion in infinite Mohr-Coulomb (M-C) soil mass. The prediction model of limiting grouting pressure of compaction grouting was proposed with limit equilibrium principle, which was validated by comparing the results in El-Kelesh et al. (2001) and numerical method. Furthermore, using the proposed prediction model, the vertical and horizontal grouting tube techniques were adopted to deal with the subgrade settlement in Shao-huai highway at Hunan Provence of China. The engineering applicability and effectiveness of the proposed model were verified by the field test. The research on the prediction model for the limiting grouting pressure of compaction grouting provides practical example to the rapid treatment technology of subgrade settlement.