• Title/Summary/Keyword: expansion tube

Search Result 292, Processing Time 0.026 seconds

MODELING ON FLOW CHARACTERISTICS OF INERTANCE PULSE TUBE CRYOCOOLER (관성관 맥동관 극저온 냉동기의 유동 특성 모델링)

  • Han, S.H.;Lee, K.H.;Choi, J.W.;Kim, J.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.14-19
    • /
    • 2014
  • The flow characteristics of inertance pulse tube cryocooler(IPTC) was investigated with a computational thermal fluid dynamics for the reciprocating flow in IPTC including the piston movement of linear compressor. Two dimensional axisymmetric modeling was applied for the flow in an IPTC with a clearance between the piston and cylinder wall of linear compressor. The pressure, velocity, and temperature distribution were examined for the steady state. These were compared with previous results to confirm the validity in the modeling and computational results. The leakage between piston and cylinder wall affect the cooling capacity seriously. The dependence on mesh numbers were also examined to obtain a proper mesh numbers to improve the accuracy of calculation, which showed significant effect on the results. The user-defined function was used for the process of compression and expansion of piston.

Theoretical study on compression wave propagating in a sudden reduction duct (급축소관을 전파하는 압축파에 관한 이론적 연구)

  • Kim, Hui-Dong;Kim, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.89-98
    • /
    • 1997
  • Compression waves propagating in a high speed railway tunnel impose large pressure fluctuations on the train body or tunnel structures. The pressure fluctuations can cause ear discomfort for the passengers and increase the aerodynamic resistance of trains. As a fundamental research to resolve the pressure wave phenomenon in the tunnel, a steady theory of Chester-Chisnell- Whitham was applied to a simple shock tube with a sudden cross-sectional area reduction to model trains inside the tunnel. The results of the present theoretical analysis were compared with the experiments of the shock tube. The results show that the reflected compression wave from the model becomes stronger as the strength of incident compression wave and the blockage ratio increase. However, the compression wave passing through the model is not strongly dependent on the blockage ratio. The theoretical results are in good agreement with the experiments.

HIGH-SPEED FLOW PHENOMENA IN COMPRESSIBLE GAS-LIQUID TWO-PHASE MEDIA (압축성 기-액 이상매체중의 고속 유동현상)

  • Shin, Byeong-Rog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.249-257
    • /
    • 2007
  • A high resolution numerical method aimed at solving gas-liquid two-phase flow is proposed and applied to gas-liquid two-phase shock tube problem. The present method employs a finite-difference 4th-order Runge-Kutta method and Roe's flux difference splitting approximation with the MUSCL TVD scheme. By applying the homogeneous equilibrium cavitation model, the present density-based numerical method permits simple treatment of the whole gas-liquid two-phase flow field, including wave propagation and large density changes. The speed of sound for gas-liquid two-phase media is derived on the basis of thermodynamic relations and compared with that by eigenvalues. By this method, a Riemann problem for Euler equations of one dimensional shock tube was computed. Numerical results such as detailed observations of shock and expansion wave propagations through the gas-liquid two-phase media and some data related to computational efficiency are made. Comparisons of predicted results and exact solutions are provided and discussed.

  • PDF

Wolsong 3&4 Steam Generator Tube Inspection (월성 3,4호기 증기발생기 전열관 검사)

  • Jang, Kyoung-Sik;Kwon, Dong-Ki;Choi, Jin-Hyuk;Son, Tai-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.859-866
    • /
    • 2001
  • During the Pre-service Inspection for Wolsong Unit 3&4 in 1997/1998 respectively, 17 Distorted Roll Transition indications(over expanded beyond tubesheet secondary face) were identified at the Unit 4 (S/G B, D). Six(6) tubes out of these tubes were plugged in 1998. However the first Periodic Inspection identified additional 110 indications in 1999 and 2000. The additionally identified 110 indication call, not reported at the Pre-service Inspection, are; 2 Not-Finally-Expanded-Tubes and 108 Distorted Roll Transition tubes. Design limit of each Steam Generator tube Plugging is 6.4%. Plugging was performed by the Steam Generator manufacturer under the warranty. When Distorted Roll Transition indications were first identified on the Unit 4 in 1998 the degree of Over-expansion was measured using an inner dial-gage to make the disposition of Nonconformance report. 2 Not-Finally-Expanded-Tubes were plugged and 10 tubes out of 108 Distorted Roll Transition Tubes were also plugged as a preventive measure.

  • PDF

An Experimental Study of Liquid.Gas Heat Exchange Pipe Inserted Capillary Tube for Room Air-Conditioner (모세관 삽입 룸 에어컨용 액.가스 열교환 배관에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.702-708
    • /
    • 2006
  • This study shows the experimental characteristics of the double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for circulating of a liquid of high temperature, pressure and a gas of low temperature, pressure at the same time. So the functions of pipe and pipe's expansion and heat transfer are presented simultaneously. In the result, the temperature of gas refrigerant at the inlet of compressor increased about $5^{\circ}C$ by the heat transfer with liquid refrigerant in case of the double pipe. And liquid gas refrigerant which the temperature at the inlet of evaporator decreased about $3^{\circ}C$ comparing with the existing type flows into an evaporator COP of the double pipe increased about $7{\sim}10%$ comparing with that of the conventional pipe. And the noise of the double pipe at capillary tube is less than that of the conventional type about 3dB. Consequently. it is convinced the superiority of the double pipe in the heat loss and soundproofing aspect.

Evaluation of Integrity of the Tubes in the Horizontal Fixed Tubesheet Heat Exchanger by Using Equivalent Modeling (고정 튜브시트를 갖는 수평형 열교환기의 등가 모델링을 이용한 튜브 건전성 평가)

  • Jeon, Yun-Cheol;Kim, Tae-Wan;Jeong, Dong-Gwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.179-187
    • /
    • 2002
  • Finite element analysis was performed to evaluate the integrity of the tubes in the fixed tubesheet of horizontal type heat exchanger under operating condition. For the finite element analysis of the heat exchanger, tubes and tubesheets were equivalently modeled with concentroidal hexagonal columns and solid plates having equivalent properties for the convenience of finite element modeling, respectively. Load combination of tube pressure and thermal expansion most likely to precipitate possible failure of the tubes was selected and applied to the finite element analysis. The compressive stresses of the tubes were calculated based on displacements of each tube, which were obtained from anile element analysis. Finally, the maximum tube stress was compared with the design criterion of ASME Boiler and Pressure Vessel Code Section VIII.

IoT notification system for marine emergencies

  • Gong, Dong-Hwan
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.122-128
    • /
    • 2022
  • Minimization of human casualties in disaster situations is of paramount importance. In particular, if a marine disaster occurs, it can be directly connected to human casualties, so prompt action is needed. In the event of a marine disaster, the route and location of movement should be identified and life tubes should be used to float on the water. This paper designs and proposes an emergency IoT notification system that can quickly rescue drowning people. The maritime emergency IoT notification system consists of four main types. First, an emergency IoT device that detects the expansion of the life tube and delivers location and situation information to the emergency IoT notification server. Second, an emergency IoT web server that manages emergency information and provides notification. Third, a database server that stores and manages emergency IoT notification information. And finally, an emergency notification app that can receive and respond to emergency notification information. The emergency IoT device consists of a TPMS(Tube Pressure Monitoring System) device that checks the pressure value of the TPMS in real time and sends it to the IoT device, and an IoT device that sends the rescuer's voice information and emergency information to the emergency IoT server. Emergency information is delivered using the MQTT(Message Queuing Telemetry Transport) protocol, and voice information is delivered to the IoT server as HTTP FormData.

Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

  • Porcel, Jose M.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.2
    • /
    • pp.106-115
    • /
    • 2018
  • Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (${\leq}14F$) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established.

An Experimental Study on Application of Hydrocarbon Refrigerants for Heat Pump (히트펌프에서 탄화수소냉매 적용에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Park, Dong-Seong;Kang, Tae-Seok;Lee, Je-Myo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1264-1269
    • /
    • 2004
  • This research describes the application of hydrocarbon refrigerants for heat pump system which is needed for fish farm. Tested refrigerants are HCFC-22 and hydrocarbon refrigerants(CARE 50 and ASR-20). CARE 50 is mixture of R-290 and R-170, and ASR-20 is mixture of R-152a, R-290 and other additives. Heat pump consist of shell and tube heat exchanger, scroll compressor, expansion valve and accumulator. Manual expansion valve is used for testing of wide range evaporating temperature. Hydrocarbon refrigerants show a good performance as an alternative for HCFC-22 in the range of evaporating temperature from $-6^{\circ}C$ to $6^{\circ}C$.

  • PDF

Clinical evaluation of spontaneous pneumothorax:a review of 360 cases (자연기흉의 임상적 고찰:)

  • 장정수
    • Journal of Chest Surgery
    • /
    • v.15 no.3
    • /
    • pp.267-273
    • /
    • 1982
  • We have observed 360 cases of spontaneous pneumothorax from Jan. 1971 to Dec. 1981 at the department of Thoracic and Card iovascular Surgery, Yonsei University College of Medicine. The patients age ranged from 2 days to 95 year-old. The associated pulmonary lesions were shown pulmonary tuberculosis in 158 cases[43.9%], bullae in 35, pulmonary emphysema In 32, pneumothorax in 10, paragonimiasis In 7 and unknown underlying pathology in 109 patients. 70 [51.1 %] out of 1 37 cases who received conservative medical treatment Including thoracentesis were cured completely, but the 67 cases [48.9 %] of remaining uncured patients were treated by surgical procedures. The 290 patients who received surgical management were recovered without recurrent pneumothorax. The surgical procedures were closed thoracotomy drainage or explothoracotomy. The choice of treatment should be based on the extent of pneumothorax or the presence of underlying pulmonary disease. Tube thoracotomywas the most effective procedure in achieving the expansion of collapsed lung. On the other hand, open thoracotomy could be a good approach to recurrent pneumothorax, persistent air leakage, incomplete expansion of the lung and bilateral pneumothorax. The minithoracotomy Is the best procedure to recurrent pneumothorax.

  • PDF