• 제목/요약/키워드: existing RC buildings

검색결과 120건 처리시간 0.025초

Seismic retrofit of a steel-reinforced concrete hospital building using continuous energy-dissipative steel columns

  • Massimiliano Ferraioli;Biagio Laurenza;Angelo Lavino;Ciro Frattolillo;Gianfranco De Matteis
    • Steel and Composite Structures
    • /
    • 제47권4호
    • /
    • pp.467-488
    • /
    • 2023
  • Seismic retrofit of an existing steel-reinforced concrete hospital building that features innovative use of a continuous energy-dissipative steel column (CEDC) system is presented in this paper. The special system has been adopted to provide an efficient solution taking into account the difficulties of applying traditional intervention techniques to minimize the impact on architectural functionality and avoid the loss of building function and evacuation during the retrofit implementation. The lateral stiffness and strength of the CEDC system were defined based on the geometric and mechanical properties of the steel strip dampers. The hysteretic behavior under cyclic loadings was defined using a simplified numerical model. Its effectiveness was validated by comparing the results of full-scale experimental data available from the literature. All the main design considerations of the retrofitting plan are described in detail. The effectiveness of the proposed retrofitting system was demonstrated by nonlinear time-history analyses under different sets of earthquake-strong ground motions. The analysis results show that the CEDC system is effective in controlling the deformation pattern and significantly reducing damage to the existing structure during major earthquakes.

기계학습 기반 노후 철근콘크리트 건축물의 축력허용범위 산정 방법 (ML-based Allowable Axial Loading Estimation of Existing RC Building Structures)

  • 황희진;오근영;강재도;신지욱
    • 한국지진공학회논문집
    • /
    • 제28권5호
    • /
    • pp.257-266
    • /
    • 2024
  • Due to seismically deficient details, existing reinforced concrete structures have low lateral resistance capacities. Since these building structures suffer an increase in axial loads to the main structural element due to the green retrofit (e.g., energy equipment/device, roof garden) for CO2 reduction and vertical extension, building capacities are reduced. This paper proposes a machine-learning-based methodology for allowable ranges of axial loading ratio to reinforced concrete columns using simple structural details. The methodology consists of a two-step procedure: (1) a machine-learning-based failure detection model and (2) column damage limits proposed by previous researchers. To demonstrate this proposed method, the existing building structure built in the 1990s was selected, and the allowable range for the target structure was computed for exterior and interior columns.

보강기법에 따른 개구부가 있는 전단벽의 보강효과 규명 (Retrofit Performance of Artificially Perforated Shearwall by Retrofit Method)

  • 최현기;이진아;최윤철;최창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.29-32
    • /
    • 2008
  • 리모델링은 친환경적 접근 방법으로써 현재 수요가 증가하고 있는 추세이다. 리모델링 사업시 구조 부재를 동반한다. 그러므로 리모델링시에 구조적인 안정성을 확보하기 위해서는 적절한 보강 방법이 요구된다. 이 연구의 목적은 전단벽에 개구부가 발생하였을 경우 Passive 보강 방식과 Active 보강 방식을 이용하였을 때의 거동 특성을 파악하는 것이다. Passive 보강 방식은 CFS나 강판 등을 부착하여 손상 부재를 보강하는 방식이고, Active 보강 방식은 프리스트레싱을 이용한 균열 제어를 통해 보강력을 도입하는 방식이다. 실험 결과 각 실험체들은 전단 파괴 형태를 보여주었고 두 가지의 다른 보강 방식은 강도나 연성에 있어서 다른 결과를 보여주었다.

  • PDF

The influence of different factors on buildings' height in the absence of shear walls in low seismic regions

  • Keihani, Reza;Bahadori-Jahromi, Ali;Goodchild, Charles;Cashell, Katherine A.
    • Structural Engineering and Mechanics
    • /
    • 제76권1호
    • /
    • pp.83-99
    • /
    • 2020
  • Shear walls are structural members in buildings that are used extensively in reinforced concrete frame buildings, and almost exclusively in the UK, regardless of whether or not they are actually required. In recent years, the UK construction industry, led by the Concrete Centre, has questioned the need for such structural elements in low to mid-rise reinforced concrete frame buildings. In this context, a typical modern, 5-storey residential building is studied, and its existing shear walls are replaced with columns as used elsewhere in the building. The aim is to investigate the impact of several design variables, including concrete grade, column size, column shape and slab thickness, on the building's structural performance, considering two punching shear limits (VEd/VRd,c), lateral drift and accelerations, to evaluate its maximum possible height under wind actions without the inclusion of shear walls. To facilitate this study, a numerical model has been developed using the ETABS software. The results demonstrate that the building examined does not require shear walls in the design and has no lateral displacement or acceleration issues. In fact, with further analysis, it is shown that a similar building could be constructed up to 13 and 16 storeys high for 2 and 2.5 punching shear ratios (VEd/VRd,c), respectively, with adequate serviceability and strength, without the need for shear walls, albeit with thicker columns.

Nonlinear shear-flexure-interaction RC frame element on Winkler-Pasternak foundation

  • Suchart Limkatanyu;Worathep Sae-Long;Nattapong Damrongwiriyanupap;Piti Sukontasukkul;Thanongsak Imjai;Thanakorn Chompoorat;Chayanon Hansapinyo
    • Geomechanics and Engineering
    • /
    • 제32권1호
    • /
    • pp.69-84
    • /
    • 2023
  • This paper proposes a novel frame element on Winkler-Pasternak foundation for analysis of a non-ductile reinforced concrete (RC) member resting on foundation. These structural members represent flexural-shear critical members, which are commonly found in existing buildings designed and constructed with the old seismic design standards (inadequately detailed transverse reinforcement). As a result, these structures always experience shear failure or flexure-shear failure under seismic loading. To predict the characteristics of these non-ductile structures, efficient numerical models are required. Therefore, the novel frame element on Winkler-Pasternak foundation with inclusion of the shear-flexure interaction effect is developed in this study. The proposed model is derived within the framework of a displacement-based formulation and fiber section model under Timoshenko beam theory. Uniaxial nonlinear material constitutive models are employed to represent the characteristics of non-ductile RC frame and the underlying foundation. The shear-flexure interaction effect is expressed within the shear constitutive model based on the UCSD shear-strength model as demonstrated in this paper. From several features of the presented model, the proposed model is simple but able to capture several salient characteristics of the non-ductile RC frame resting on foundation, such as failure behavior, soil-structure interaction, and shear-flexure interaction. This confirms through two numerical simulations.

BTL 적용 교육시설의 최적 건축공법 평가에 관한 연구 (A Study on Evaluation of Optimal Construction Method of BTL Projects - Focused on Educational Facilities -)

  • 박유영;조봉호;김기현;이춘경;박태근
    • 한국건설관리학회논문집
    • /
    • 제10권3호
    • /
    • pp.22-31
    • /
    • 2009
  • BTL사업 형태로 발주되는 교육시설의 공사에서는 소요 공기 최소화와 임시교사 설치로 인한 별도의 비용 소모, 그리고 학기 중에 학교 사용자들이 겪는 불편사항으로 주무관청, 민간사업자 그리고 학교사용자의 갈등이 깊어지는 문제가 발생하고 있다. 본 연구에서는 이러한 당면 과제를 공법적인 측면에서 해결하고자, 기존 학교 공사에 일반적으로 적용되는 RC공법과 최근 몇 년 사이에 교육시설의 대안공법으로 주목받고 있는 모듈러 공법을 포함한 몇 개의 대안을 설정하고 교육시설의 BTL사업에 적합한 건축공법을 제안하였으며 각 대안에 소요되는 공사비를 산출하고 공사기간을 분석하여 이를 평가하였다.

고강도 표면매립용철근과 탄소섬유시트로 보강된 비연성 철근콘크리트 골조의 실물 진동기 실험 (Full-Scale Shaker Testing of Non-Ductile RC Frame Structure Retrofitted Using High-Strength Near Surface Mounted Rebars and Carbon FRP Sheets)

  • 신지욱;전종수
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.43-54
    • /
    • 2019
  • Existing reinforced concrete frame buildings designed for only gravity loads have been seismically vulnerable due to their inadequate column detailing. The seismic vulnerabilities can be mitigated by the application of a column retrofit technique, which combines high-strength near surface mounted bars with a fiber reinforced polymer wrapping system. This study presents the full-scale shaker testing of a non-ductile frame structure retrofitted using the combined retrofit system. The full-scale dynamic testing was performed to measure realistic dynamic responses and to investigate the effectiveness of the retrofit system through the comparison of the measured responses between as-built and retrofitted test frames. Experimental results demonstrated that the retrofit system reduced the dynamic responses without any significant damage on the columns because it improved flexural, shear and lap-splice resisting capacities. In addition, the retrofit system contributed to changing a damage mechanism from a soft-story mechanism (column-sidesway mechanism) to a mixed-damage mechanism, which was commonly found in reinforced concrete buildings with strong-column weak-beam system.

Probabilistic earthquake risk consideration of existing precast industrial buildings through loss curves

  • Ali Yesilyurt;Seyhan O. Akcan;Oguzhan Cetindemir;A. Can Zulfikar
    • Geomechanics and Engineering
    • /
    • 제37권6호
    • /
    • pp.565-576
    • /
    • 2024
  • In this study, the earthquake risk assessment of single-story RC precast buildings in Turkey was carried out using loss curves. In this regard, Kocaeli, a seismically active city in the Marmara region, and this building class, which is preferred intensively, were considered. Quality and period parameters were defined based on structural and geometric properties. Depending on these parameters, nine main sub-classes were defined to represent the building stock in the region. First, considering the mean fragility curves and four different central damage ratio models, vulnerability curves for each sub-class were computed as a function of spectral acceleration. Then, probabilistic seismic hazard analyses were performed for stiff and soft soil conditions for different earthquake probabilities of exceedance in 50 years. In the last step, 90 loss curves were derived based on vulnerability and hazard results. Within the scope of the study, the comparative parametric evaluations for three different earthquake intensity levels showed that the structural damage ratio values for nine sub-classes changed significantly. In addition, the quality parameter was found to be more effective on a structure's damage state than the period parameter. It is evident that since loss curves allow direct loss ratio calculation for any hazard level without needing seismic hazard and damage analysis, they are considered essential tools in rapid earthquake risk estimation and mitigation initiatives.

철근콘크리트 바닥판 평면확장 공법에 대한 연구 (Study on the Extension of Reinforced Concrete Slabs)

  • 김진평;김상식;최광호;전병갑;이정윤
    • 콘크리트학회논문집
    • /
    • 제18권3호
    • /
    • pp.321-330
    • /
    • 2006
  • 노후화된 철근콘크리트 공동주택을 리모델링할 경우에 거주성의 향상을 위하여 기존 바닥판에 새로운 바닥판을 신설하여 기존 건물의 평면을 확장시키는 경우가 많다. 새로운 바닥판이 기존 바닥판에 연결될 경우에 두 바닥판의 접합 방법에 따라서 힘의 흐름이 달라진다. 이 연구에서는 8개의 부분 실험체와 24개의 전체 실험체를 제작하여 3종류의 강절점으로 연결된 바닥판 접합부의 파괴모드와 내력을 실험적으로 평가하였다. 실험체의 주요변수는 강절점 접합방식, 철근의 묻힘 깊이(0, 50, 60, 100, 120mm), 묻힘 길이(100, 200, 300mm), 철근의 배근 간격(150, 200, 300, 450mm)이다. 실험에서 강절점으로 연결된 바닥판의 휨내력은 일체화된 바닥판의 철근항복시의 내력과 유사하였다.

RC 아파트 바닥의 수직진동 성능 평가 (Evaluation of Floor Vibration Existing in Apartment Building)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.967-972
    • /
    • 2003
  • In recent years building floors has become larger and more spacious due to the development of new design methods and high strength and light weight materials. However, such long span floor systems may provide smaller amount of damping and have longer period so that they would be more vulnerable to the floor vibration. This study attempts to evaluate the performance of the floors in typical apartment buildings. Four different floors with the area of 43.2$m^2$, 41.44$m^2$, 34.5$m^2$, and 28.89$m^2$ were investigated. The guideline provided by AISC(997) and human perception level of Korean people proposed by S. W. Han(2003) are used to check the acceptability of the floor vibration.

  • PDF