• Title/Summary/Keyword: exhaust pollution

Search Result 365, Processing Time 0.022 seconds

A Study on Fine Dust Modeling for Air Quality Prediction (미세먼지 확산 모델링을 이용한 대기질 예측 시스템에 대한 연구)

  • Yoo, Ji-Hyun
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1136-1140
    • /
    • 2020
  • As air pollution caused by fine dust becomes serious, interest in the spread of fine dust and prediction of air quality is increasing. The causes of fine dust are very diverse, and some fine dust naturally occurs through forest fires and yellow dust, but most of them are known to be caused by air pollutants from burning fossil fuels such as petroleum and coal or from automobile exhaust gas. In this paper, the CALPUFF model recommended by the US EPA is used, and CALPUFF diffusion modeling is performed by generating a wind field through the CALMET model as a meteorological preprocessing program that generates a three-dimensional wind field, which is a meteorological element required by CALPUFF. Through this, we propose a fine dust diffusion modeling and air quality prediction system that reflects complex topography.

Study on Analysis of Buoyancy Effect in Air-heating Collector using Solar Heat (태양열을 이용한 공기가열 집열기의 부력효과 해석 연구)

  • Yang, Young-Joon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.467-474
    • /
    • 2021
  • The renewable energy is known as eco-friendly energy to reduce the use of fossil fuel and decrease the environmental pollution due to exhaust gas. Targets of solar collector in domestic are usually acquisitions of hot water and hot air. System of air-heating collector is one of the technologies for obtaining hot air in cases of especially heating room and drying agricultural product. The purpose of this study is to investigate the characteristics of thermal flow such as relative pressure, velocity, outlet temperature and buoyancy effect in air-heating collector using solar heat. The flow field of air-heating collector was simulated using ANSYS-CFX program and the behaviour of hot air was evaluated with SST turbulence model. As the results, The streamline in air-heating collector showed several circular shapes in case of condition of buoyancy. Temperature difference in cross section of outlet of air-heating collector did not almost show in cases of buoyancy and small inlet velocity. Furthermore merit of air-heating collector was not observed in cases of inlet velocities. Even though it was useful to select condition of buoyancy for obtaining high temperature, however, it was confirmed that the trade off between high temperature of room and rapid injection of hot air to room could be needed through this numerical analysis.

Properties of Fine Dust Adsorption Matrix According to the Powdered Activated Carbon Mixing Method based on Blast Furnace Slag (고로슬래그 기반 분말활성탄 혼입방법에 따른 미세먼지 흡착형 경화체의 특성)

  • Kim, Yeon-Ho;Jo, Eun-Seok;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.68-69
    • /
    • 2020
  • Recently, the problem of air pollution is drawing attention as a social problem worldwide. Particularly, fine dust is the biggest issue among air pollutants, and it is analyzed that fine dust is generated from air pollutants such as burning fossil fuels such as petroleum or coal, or exhaust gases from automobiles. In addition, yellow dust originating from China adjacent to Korea flows into the Korean Peninsula in a western wind, causing the concentration of fine dust to deteriorate. Fine dust is a harmful substance to the human body such as asthma or respiratory disease, and awareness of the risk is also increasing to a degree designated as a primary carcinogen. In this study, as a method for improving the indoor air quality, the Properties of the matrix according to the mixing ratio of powdered activated carbon based on blast furnace slag are reviewed. The flexural strength and compressive strength were measured, and a fine dust concentration measurement experiment will be conducted later.

  • PDF

Recent Trends of Vessel-Source Pollution (선박 기인 오염물의 처리동향 및 대책)

  • Park, Sang-Ho;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.97-104
    • /
    • 2006
  • Though stringent guidelines are in place to protect the harbor environment, pollution from ships, from the ports terminals. Discharge from the ballast tanks of ships, though illegal, does occur. Such vessels, arriving from distant ports of call, can introduce exotic species of plants and animals, causing disruption of the local food web. Discharges rich in nitrogen can generate the rapid growth of plankton, eventually leading to a condition known as red tide that is lethal to some coastal organisms. In addition to the harbor's negative effects on marine organisms, the diesel engines of the ships and the trucks that haul cargo to and from the ports release large volumes of diesel exhaust into the atmosphere. IMO(International Maritime Organization) is strongly proceeding with adoption of a new maritime environment convention and coming into effect for regulation enhancement about the pollutants which are happened in a ship recently. Study about the conventions that our country currently comes into effect, and there is during forwarding and correspondence must be performed effectively. In this paper, International convention on the control of harmful Anti-Fouling system on ship, Ballast water management, Prevention of air pollution from ships, treat a main pending problem in ocean related environmental regulation convention.

  • PDF

PM10 and Associated Trace Elements in the Subway Cabin of Daejeon by Instrumental Neutron Activation Analysis (기기 중성자방사화 분석을 이용한 대전 지하철 객차 내 PM10과 미량성분의 특성)

  • Jeong, Jin Hee;Lim, Jong Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.459-467
    • /
    • 2016
  • In order to assess the pollution status and distribution characteristics of PM and PM-bound species, PM10 samples were collected using mini-volume air sampler at the subway cabin in Daejeon city. Measurements of about 24 elements including toxic metals (e.g., As, Cr, Mn, V, Zn) in PM10 were made by instrumental neutron activation analysis and X-ray fluorescence. The average PM10 concentration was $59.3{\pm}14.5{\mu}g/m^3$ in the subway cabin with a range of 42.2 to $97.4{\mu}g/m^3$, while the associated elemental concentrations were varied in the range of $10^{-3}$ to $10^5ng/m^3$. It was found that the concentration of Fe ($12.5{\mu}g/m^3$) was substantially higher than any other element. The Fe concentration was apportioned by about 20% of the PM10 concentration. The results of factor analysis indicate that there are no more than six sources in the cabin (e.g., brake-nonferrous metal particle, resuspended rail dust, fuel combustion, vehicle exhaust, black carbon, Cr-related).

Experimental Study on the Dependence of Variation in Performance of a High-Temperature Generator on Its Operating Conditions (운전조건 변화가 고온재생기의 성능에 미치는 영향에 관한 실험적 연구)

  • Bae, Kyungjin;Kwak, Myoungseok;Cho, Honghyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.389-397
    • /
    • 2014
  • An absorption chiller-heater using only a natural refrigerant hardly causes any environmental pollution. In an absorption chiller-heater, the performance of its high-temperature generator, which uses exhaust gases, is essential to achieving superior system performance. To investigate the performance of such a high-temperature generator, a laboratory-scale high-temperature generator working with exhaust gases was designed and tested. Changes in the performance of the high-temperature generator as a function of inlet conditions of the absorbing solution, such as air inlet temperature and mass flow, were investigated. It was observed that when the air mass flow rate ratio was increased from 80% to 120%, the heat capacity was increased by 30%, 33%, 34%, and 37%, respectively. Additionally, when the air inlet temperature was elevated from $170^{\circ}C$ to $210^{\circ}C$ for absorption solution concentrations of 56%, 55%, 545, and 53%, the heat capacity increased by 140%, 160%, 220%, and 224%, respectively.

The Factor Analysis of Airborn Fiber Concentrations at Parking Lots in Seoul (서울 시내 일부 주차장의 공기중 섬유농도에 영향을 미치는 인자 분석)

  • Moon, Ji Young;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.157-167
    • /
    • 1994
  • This study was conducted to analyze the relationship between the types of fiber and its content and the levels of airborne fiber concentrations at eight parking lots where sprayed insulation material was found on the walls and ceilings. Also this study was designed to find the relationship between the levels of airborne fiber concentrations and such variables as air current, humidity, total exhaust volume, surface condition of insulation material and building age. The results obtained were as follows : 1. No significant correlation was found between the levels of airborne tiber concentration and the building age, air current, humidity, total exhaust volume, space and the number of traffics. 2. A significant correlation was found between the levels of airborne fiber concentration and the MMMF content of the insulation material(r=0.7594). However, no significant correlation was found between the levels of airborne fiber concentration and total fiber content of insulation material. 3. The differences of the airborne fiber concentrations among Cateogory 1, 2 and 3 classified by the degrees of surface insulation material maintenance were very significant. 4. Two bulk samples contained 30% crodicolite and 1% anthophylite. The MMMFs, in all parking lots, included mineral wool, cellulose fiber, trace cellulose fiber, trace tiber glass and vermiculite. 5. The mean value and the range of airborne fiber concentrations at 8 parking lots were $0.0239{\pm}0.0095f/cc$ and 0.0054-0.0447 f/cc, respectively. The fiber concentrations of 35 out of 38 samples(92%) were over 0.01 f/cc which is the Environment Administration's recommended asbestos level for the underground space. This study suggests that most of building insulation materials used in Korea, contain MMMF and sometimes asbestos. Currently, MMMF pollution levels may exceed the Environment Administration's recommended level for underground space. It has been found that airborne fiber concentrations increased significantly with MMMF content and with the maintenance condition of surface material. Therefore, it is recommended that a proper management technique should be developed and immediately implemented since the conditions of surface material will be gradually deteriorated due to building age and usage. Since health hazards of the MMMF, similar to those of asbestos, are being gradually acknowledged, a proper management technique which is applicable to control total airborne fiber concentrations, both asbestos and MMMF, be developed and an acceptable indoor air standard be promulgated as early as possible.

  • PDF

Prediction of NOx emission for marine gas engines (선박용 가스엔진의 NOx 배출량예측에 관한 연구)

  • Jang, Ha-Seek;Lee, Ji-Woong;Lee, Kang-Ki;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.658-665
    • /
    • 2014
  • Natural gas for marine diesel engine is considered as an important and clean source of energy because of simultaneously reducing the emission of NOx, SOx and GHG. Especially with a appearance of shale gas, the using of natural gas has been investigated aggressively and expected to expand rapidly. By the reports, gas engine and diesel engine were both in a similar performance in the power aspect, and the SFOC of gas engine was shown a little better than that of diesel engine. But the characteristics of exhaust gas emission were different according to various combustion technologies. And with lean burn technology, the emission of NOx could be reduced to 85% lower than that of diesel engine. In this paper, it was described that a simulation program has been developed to predict NOx emission. The developed program is adopted two-zone model and Wiebe function for combustion in cylinder. The effects of premixed and diffusive combustion could be simulated by using the excess air ratio as input data. And it was confirmed that the results of simulation were agreed with the general trends of exhaust gas emission according to various combustion conditions such as lean burn, premixed and diffusive combustion.

Measuring the Non-market Value of the Introduction of Electric Vehicles to National Parks Against Climate Change (기후변화의 대응수단으로서 국립공원 내 전기자동차 도입의 비시장적 가치 추정에 관한 탐색적 연구)

  • Kim, Sang-Tae;Min, Woong-Ki;Kim, Nam-Jo
    • Review of Culture and Economy
    • /
    • v.17 no.2
    • /
    • pp.81-102
    • /
    • 2014
  • As carbon dioxide, the main greenhouse gas, is generally emitted by vehicles, the development and distribution of electric cars is important for the sustainability of environmentally-friendly tourism, especially in national parks. National parks in Korea, however, still see the use of traditional vehicles powered by internal combustion engines in the handling of visitors and the transportation of goods and staff. Such engines being the cause of environmental problems such as exhaust emission and noise pollution, the introduction of electric cars in national parks is needed. This study aims to analyze the economic value of electric cars in national parks as well as contribute to the development of the Green Transportation model in tourism destinations. The study used a logit model to estimate the willingness to pay for the introduction of electric cars in national parks. Adults over the age of twenty, with gender and age apportioned equally, were surveyed using questionnaires that included dichotomous as well as demographic questions. The findings show that the amount an individual is willing to pay for the purpose of environmental conservation is 3,948 won, while the value the national parks would derive from the use of electric cars is 56,138,130,000 won. The introduction of electric cars in national parks is expected to offer both direct and indirect benefits while helping to improving the environment of the national parks by eliminating exhaust emission and noise. This introduction would also be a response to climate change that can be taken by society as a whole.

Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel (고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석)

  • You, Han-Jo;Jung, Yeon-Hoon;Kim, Jin-guil;Shin, Hyung-Soon;Lim, Yoon-Jung;Lee, Sang-Soo;Son, Hae-Jun;Lim, Sam-Hwa;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.