Journal of Physiology & Pathology in Korean Medicine
/
v.35
no.6
/
pp.249-254
/
2021
The aim of this study was to raise awareness about smoking and to facilitate the induction of smoking cessation. The participants were 49 patients who showed intention to participate in the test. The participants who had done a questionnaire, were asked to quit smoking for about an hour. After taking the breath deeply, they stopped for 20 seconds and measured breathing slowly. Carbon monoxide in the exhalation was higher when the daily smoking amount was higher and the smoking duration was longer, but not significant. In the case of smoking after meal and smoking in bed in the morning, the carbon monoxide level was significantly higher than that in the case of not smoking. It was significantly associated with skin allergic symptoms. The usual exercise habits, drinking and the respiratory disease were not correlated with carbon monoxide levels.
We employed an unprecedented technique to synthesize porous $WO_3@SnO_2$ nanofibers exhibiting core-shell and fiber-in-tube configurations. Firstly, 2-methylimidazole was uniformly incorporated in as-spun nanofibers containing ammonium metatungstate hydrate and the sacrificial polymer (polyacrylonitrile). Secondly, the 2-methylimidazole on the surfaces of nanofibers was complexed with tin(II) chloride ($SnCl_2$) via simple impregnation of the as-spun nanofibers in ethanol containing tin(II) chloride dihydrate ($SnCl_2{\cdot}2H_2O$). The presence of vacant p-orbitals in tin (Sn) and the nucleophilic nitrogen on the imidazole ring allowed for the reaction between $SnCl_2$ and 2-methylimidazole, forming adducts on the surfaces of the as-spun nanofibers. The calcination of these nanofibers resulted in porous $WO_3@SnO_2$ nanofibers with a higher surface area ($55.3m^2{\cdot}g^{-1}$) and a better response to 1-5 ppm of acetone than pristine $SnO_2$ NFs synthesized using a similar method. An improved response to acetone was achieved upon functionalization of the $WO_3@SnO_2$ nanofibers with catalytic palladium nanoparticles. This work demonstrates the potential application of $WO_3@SnO_2$ nanofibers as sensing layers for chemiresistive sensory devices for the detection of acetone in exhaled breath.
In this work, we prepared porous WO3 nanofibers (NFs) functionalized by bio-inspired catalytic $Cr_2O_3$ and $Co_3O_4$ nanoparticles as highly sensitive and selective $H_2S$ gas sensing layers. Highly porous 3-dimensional (3D) NFs networks decorated by well-dispersed catalyst NPs exhibited superior $H_2S$ gas response ($R_{air}/R_{gas}$ = 46 at 5 ppm) in high humidity environment (95 %RH). In particular, the sensors showed outstanding $H_2S$ selectivity against other interfering analytes (such as acetone, toluene, CO, $H_2$, ethanol). Exhaled breath sensors using $Cr_2O_3$ and $Co_3O_4$ catalysts-loaded $WO_3$ NFs are highly promising for the accurate detection of halitosis.
Lee, Jong Seong;Shin, Jae Hoon;Baek, Jin Ee;Choi, Byung-Soon
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.29
no.3
/
pp.404-413
/
2019
Objectives: Chronic obstructive pulmonary disease(COPD) is an important cause of mortality in workers exposed to hazardous dust, such as crystalline silica or coal, and COPD is related to inflammation and oxidative stress in the lung. The aim of this study was to evaluate the association of oxidative stress and inflammation to COPD in retired workers exposed to mineral dust. Methods: The levels of malondialdehyde(MDA) in EBC as biomarkers for oxidative stress and C-reactive protein(CRP) and lactate dehydrogenase(LD) as biomarkers for inflammation were measured in 107 male subjects(63 pneumoconiosis and 42 COPD subjects). Results: Mean levels of EBC MDA(2.03 nmol/L vs. 4.65 nmol/L, p=0.010) and serum LD(170.3 U/L vs. 185.9 U/L, p=0.022) were significantly higher in subjects with COPD, but mean levels of serum CRP(p=0.469) did not show a statistical difference between the study groups. Level of EBC MDA was negatively correlated with ${%}FEV_1$ predicted(r=-0.279, p=0.004) and ${%}FEV_1/FVC$ ratio(r=-0.397, p<0.001). Conclusions: These results suggest that EBC is a useful biological matrix for investigation of respiratory oxidative stress. High levels of EBC MDA and serum LD are related to COPD in retired workers exposed to mineral dust.
There has been an increased awareness of the need to confirm the chloroform exposure associated with using chlorinated household water. Ten of a 30-minute tub bath were normally taken by two volunteers in a bathroom of an apartment. Chloroform concentrations were measured in bathing water and bathroom air, and exhaled breath of the subjects prior to and after bathing. Bathing using chlorinated tap water resulted in a chloroform exposure and caused a body burden. Based on the difference of chloroform concentrations between breath samples collected prior to and after bathing, the chloroform body burden from a 30-minute bath was estimated to be about 8 to 26 folds higher than that prior to the bath. The mean water and bathroom air chloroform concentrations measured to evaluate the body burden were $9.4\mu\textrm{g}/l$ and TEX>$14.9\mu\textrm{g}/m^3$, respectively. The chloroform level of the bathroom air was 각 to 130 times higher than that of the living-room air. The relationship between the bathroom air and the corresponding breath chloroform concentrations were significant with p=0.03 and $R^2=0.47$.
There has been an increased awareness of the need to confirm the chloroform exposure associated with using chlorinated household water. Ten of a 30-minute tub bath were normally taken by two volunteers in a bathroom of an apartment. Chloroform concentrations were measured in bathing water and bathroom air, and exhaled breath of the subjects prior to and after bathing. Bathing using chlorinated tap water resulted in a chloroform exposure and caused a body burden. Based on the difference of chloroform concentrations between breath samples collected prior to and after bathing, the chloroform body burden from a 30-minute bath was estimated to be about 8 to 26 folds higher than that prior to the bath. The mean water and bathroom air chloroform concentrations measured to evaluate the body burden were $9.4\mu\textrm{g}/l$ and TEX>$14.9\mu\textrm{g}/m^3$, respectively. The chloroform level of the bathroom air was 각 to 130 times higher than that of the living-room air. The relationship between the bathroom air and the corresponding breath chloroform concentrations were significant with p=0.03 and $R^2=0.47$.
Byeong-Hun Yu;Sung Do Yun;Chan Woong Na;Ji-Wook Yoon
Journal of Surface Science and Engineering
/
v.56
no.6
/
pp.393-400
/
2023
Acetone, a metabolite detected from the exhaled breath of people doing a diet, can be used for non-invasive monitoring of diet efficiency. Thus, gas sensors with rapid response and recovery characteristics to acetone need to be developed. Herein, we report ultrafast acetone sensors using Ce-doped In2O3 nanoparticles prepared by the one-pot microwave-assisted hydrothermal method. The pure In2O3 sensor shows a high response and fast response time (τres = 6 s) upon exposure to 2 ppm acetone at 300 ℃, while exhibiting a relatively sluggish recovery speed (τrecov = 1129 s). When 20 wt% Ce is doped, the τrecov of the sensor significantly decreased to 45 s withholding the fast-responding characteristic (τres = 6 s). In addition, the acetone response (resistance ratio, S) of the sensor is as high as 5.8, sufficiently high to detect breath acetone. Moreover, the sensor shows similar acetone sensing characteristics even under a highly humid condition (relative humidity of 60%) in terms of τres (6 s), τrecov (47 s), and S (4.7), demonstrating its high potential in real applications. The excellent acetone sensing characteristics of Ce-doped In2O3 nanoparticles are discussed in terms of their size, composition, phase, and oxygen adsorption on the sensing surface.
Gastric cancer is the fifth most common malignancy in the world and still remains the third and fifth leading cause of cancer death in male and female, respectively. In terms of the cancer survival, the survival of gastric cancer is low in the West with showed 5-year survival rates of 10-30%, whereas the survival rates in Asia is more than 50%. The reason of the higher survival rate from gastric cancer in Asia partially related with the availability of gastric cancer screening programs, however, the population-based screening for gastric cancer has been conducted just in Korea and Japan. Therefore, more effective method for detecting the gastric cancer is needed for countries without a population-based gastric cancer screening. Endoscopy is the most effective method for diagnosis of gastric cancer however, it requires a large infrastructure including a large number of endoscopic equipment and well-trained endoscopists. To overcome these problems, several noninvasive methods (such as serologic markers, biomarkers, cancer autoantibodies, and exhaled breath analysis) for diagnosis of gastric cancer screening are suggested. This review addresses the conventional methods and the emerging methods for gastric cancer screening.
The purpose of this study was to compare the effect of education between CAI(Computer Assisted Instruction) and lectures for smoking cessation among male students who attended vocational high schools. Conducted from February 24th to April 26th, 2003, the study design was quasi-experimental with nonequivalent control group pretest-posttest design. The study subjects were 60 male students in K vocational high school in Daegu city, who were present smokers and had more than 7.0 ppm concentration level of carbon monoxide. Thirty students were randomly chosen as the experimental group which applied CAI education method for smoking cessation. The other 30 students served as the control group which received lecture education method of 40 minutes on four consecutive days. CAI education for smoking cessation was composed of ready-made individual learning contents, counseling by using cyber-communication, writing a letter to stop smoking, and writing a written agreement for smoking cessation. Lecture education for smoking cessation was composed of a ready-prepared lecture for the group, writing a letter to stop smoking, and writing a written agreement for smoking cessation. To measure smoking related knowledge, Jeong Ree Roh(1996)'s smoking related knowledge scale$(Cronbach's\;{\alpha}=0.84)$ was modified and used by the researcher. To measure smoking related attitude, Jeong Ree Roh(1996)'s smoking related attitude scale$(Cronbach's\;{\alpha}=0.91)$ was modified and used by the researcher. Smoking related knowledge scale's Cronbach's $\alpha$ was 0.83 in the pilot study and 0.93 in this study. Smoking related attitude scale's Cronbach's a was 0.80 in the pilot study and 0.98 in this study. To determine the smoking amount, the number of cigarettes smoked per day was checked. The concentration level of CO in the exhaled breath was measured (Micro CO Cat. No. MCO2, UK). Data was analyzed by $x^2-test$, t-test, repeated measures ANOVA. simple main effects, and time contrast test with SPSS/Win 11.0 program. The results of this study were as follows: 1. The first hypothesis. that 'Smoking-related knowledge score in the experimental group by using CAI education for smoking cessation will be higher than that in the control group by using lecture education for smoking cessation', was not supported. 2. The second hypothesis, that 'Smoking-related attitude in the experimental group by using CAI education for smoking cessation will be higher than that in the control group by using lecture education for smoking cessation'. was supported(F=6490.79. p=0.000). 3. The third hypothesis. that 'Smoking amount in the experimental group by using CAI education for smoking cessation will be less than that in the control group by using lecture education for smoking cessation'. was supported. 1) The third-1st sub-hypothesis. that 'The number of cigarettes smoked per day in the experimental group by using CAI education for smoking cessation will be less than that in the control group by using lecture education for smoking cessation'. was supported(F=134.19. p=0.000). 2) The third-2nd sub-hypothesis. that 'The concentration level of CO by ppm per one exhaled breath in the experimental group by using CAI education for smoking cessation will be lower than that in the control group by using lecture education for smoking cessation"' was supported(F=268.55. p=0.000). From the above results. CAI education can be an effective intervention to improve smoking-related knowledge and attitude. and to reduce the number of cigarettes smoked per day and the concentration level of CO by ppm per one exhaled breath. Lecture education can be effective to improve smoking-related knowledge. In the future, when CAI education and lecture education for smoking cessation are applied on the school nursing field. the students can gain a comprehensive understanding of smoking cessation, changes in smoking-related knowledge. smoking-related attitude and reducing smoking amount. Furthermore, CAI education for smoking cessation could be developed as an individual self initiative program and could give a guideline to apply CAI education for smoking cessation in other field.
A high level of particulate matter (PM) in air is correlated with the onset and development of chronic respiratory diseases. We conducted a systematic literature review, searching the MEDLINE, EMBASE, and Cochrane databases for studies of biomarkers of the effect of PM exposure on chronic respiratory diseases and the progression thereof. Thirty-eight articles on biomarkers of the progression of chronic respiratory diseases after exposure to PM were identified, four of which were eligible for review. Serum, sputum, urine, and exhaled breath condensate biomarkers of the effect of PM exposure on chronic obstructive pulmonary disease (COPD) and asthma had a variety of underlying mechanisms. We summarized the functions of biomarkers linked to COPD and asthma and their biological plausibility. We identified few biomarkers of PM exposure-related progression of chronic respiratory diseases. The included studies were restricted to those on biomarkers of the relationship of PM exposure with the progression of chronic respiratory diseases. The predictive power of biomarkers of the effect of PM exposure on chronic respiratory diseases varies according to the functions of the biomarkers.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.